. REMOTE CAMERA CONTROLLER RM-LP100U RM-LP100E INSTRUCTIONS . Specifications and appearance of this unit are subject to change for further improvement without prior notice. Details For details on settings and operation, refer to “INSTRUCTIONS” on the website. Please check the latest INSTRUCTIONS, tools, etc. from the URL below. North America: http://pro.jvc.com/prof/main.jsp Europe: http://www.service.jvcpro.eu/public/ China: http://www.jvc.com.cn/service/download/index.
Safety Precautions Cautions Getting Started CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN AVIS RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. CAUTION: This unit should be used withAC 120 VH, 60 Hz. To prevent electric shocks and fire hazards, DO NOT use any other power source. CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT.
IMPORTANT SAFETY INSTRUCTIONS Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9) Do not defeat the safety purpose of the polarized or groundingtype plug.
POWER CONNECTION The rating plate and the safety caution are on the bottom of the unit. The power supply voltage rating of this product is AC 220 – 240 V (For European countries, Asian countries, and United Kingdom). The power cord attached conforms to the following power supply voltage and countries. Use only the power cord designated to ensure safety and EMC regulations of each country.
ḏ䌰ἀ䒩㚠旑 Getting Started 㫥♿㞈埩䢻ḇᶮ⋏ḻ㮒␍♾䘅㱖⼌㇁奅⬛䘅䌰ἀ䒩㚠旑ɝ⍫夂䒩ㆸ⚩ἀ䒩㚭Ḩ⑂㕷忶 ⬉㱩ゐḌ柺ᶮ䘅⎅柺奅⬛澔ṏ↷御㕦㚠⺁⥌↱㫥♿㞈㞈ⅻ䘅㚠旑ᶻ㫣澐䌰ἀ䒩㚠旑澑㕣 ᶎẛ㯢㝔䌰⠄ᷠᶎẛḨ䒠⭺ḻỔ㚊⬴䘅䇪岩ɝ 䌰ἀ䒩㚠旑 旅ṷ␍㴉侘⾨晷ṷ䘅䌰ἀ䒩㚠旑⤃ᶌ㇁䢻澢 澐ᶎ⎍Ḩ⑂ᶮ⊆⎬䘅旅ṷ␍㴉侘⾨晷ṷᷠᶎ䙹⎍ɝ澑 忦㌨◩ɜḥ㳂廭㋣◩ɜ䒶亇䯼澢21ⷵ ḏḨ⑂ᶮ䘅㚊⬴䇪岩 摆 澐Qc澑 乀嵰㜀久ṷ 㚻䬲 㴳㗷㖿䢻⯐㦢⛘ ḥ㳂廭㋣◩ ṗ旅ṷ 恩ṷ⎎䥱 㯟 澐Ih澑 ȵ ȵ ȵ ȵ ȵ 㚊⬴䇪岩 ⃮Ṹ摭 ⢛㸵俕剰 ⢛㸵ḍ剰愛 澐De澑 澐Ds)WJ*澑 )QCC* 澐QCEF澑 ȵ ȵ ȵ ȵ ȵ ȵ ȵ ȵ ȵ ȵ ȵ ȵ ȵ ȵ ȵ 擊 㚭埩㞽㋯!TK0U22475!䘅奅⬛亗↷ɝ ȵ澢埩䢻学㚊⬴䇪岩⚩学恩ṷ㇁㚊⛈岩㛑㔚ᶮ䘅⎬慐⛈⚩!HC0U37683!奅⬛䘅旑慐夂㯃Ṧᶌɝ 澢埩䢻学㚊⬴䇪岩兴⮒⚩学恩ṷ䘅㝑ᶁ⛈岩㛑㔚ᶮ䘅⎬慐崆ⅻ!HC0U37683奅⬛䘅旑慐夂㯃ɝ .
Contents Getting Started Getting Started Safety Precautions ................................................................ 2 Contents ................................................................................ 6 Supplied Accessories ............................................................ 6 Main Features ........................................................................ 7 Precautions ........................................................................... 7 Name of Parts ...............
Main Features The features for the combination of this unit and the HD PTZ REMOTE CAMERA (KY-PZ100) are as follows. Equipped with full color LCD touch panel, which makes operation easy through its versatile screen configuration. Operate Camera Freely with Control Lever and Customized Buttons Equipped with a control lever and customized buttons assignable with functions, which enhances the operability of the camera. Also enables smooth pan/tilt operation.
Name of Parts Rear Panel Front Panel Getting Started F G A B C D H A B C DE F G H I J E . I A USER1 button For switching the settings menu.
Camera Operation Screen L M Getting Started N K O P A Q B S C R T D F H E G U I . J A [USER1] J [ENTER] B [F1] K [VIEW] The function assigned to the [USER1] button can be configured. The default function assigned is “EXPOSURE”. The function assigned to the [F1] knob can be configured. The default function assigned is “AE LEVEL”. C [F2] The function assigned to the [F2] knob can be configured. The default function assigned is “SPEED”.
Preparations 1 Set the power switch to “On”. Getting Started 0 The power is turned on and the POWER lamp lights up. 0 The start screen is displayed on the operation panel. The ALARM lamp lights up at the same time. During which, this unit cannot be operated. 0 The start screen disappears after about 10 seconds and the home screen is displayed. 2 Configure the settings of this unit. 0 Set the IP address of this unit as follows. A Select [SETTINGS] on the home screen of the operation panel.
Selecting and Operating a Camera Selecting a Camera Specify the camera number to display the video on the monitor. Operating a Camera Operating the PTZ (pan/ tilt/ zoom) 1 Select a camera to operate. (A P11 “Selecting a Camera”) 2 Tilt the control lever toward the direction you want the camera to move (pan/ tilt operation). 3 Operate the zoom lever to adjust the size of the field of view (zoom operation). . 1 Display the home screen.
Changing an Assigned Function Selecting the Position o Position Operation This system allows you to configure multiple shooting positions on one camera. This shooting position is referred to as “position”. The JVC HD PTZ REMOTE CAMERA KY-PZ100 network camera allows you to configure 10 groups by 10 patterns, a total of 100 shooting positions. The shooting positions configured are registered as “preset positions” and can be called up any time.
Adjusting the Camera Functions Adjusting the White Balance (R/B Gain) Changing the white balance setting 1 Select USER1 on the operation panel. 2 Select “WHITE BALANCE” in function select and tap the [ENTER] button. F1 knob can be used for WB R (R gain), F2 knob for WB B (B gain), USER1 button for WB and USER2 button for AWB TRIGGER. Executing AWB Trigger Effective if white balance mode is set to “AWB”. The white balance is automatically adjusted when the AWB Trigger button is tapped.
Setting the gain Starting the Streaming o Automatic gain mode (automatic gain adjustment) Automatic gain mode (automatic gain adjustment) is activated by setting EXPOSURE to “AUTO”. Operation 1 Select USER1 on the operation panel. 2 Select [EXPOSURE] in function select and tap the [ENTER] button. 3 Tap the USER1 button and select “AUTO”. o Manual gain mode (manual gain switching) Manual gain mode (manual gain switching) is activated by setting EXPOSURE to “MANUAL”.
Setup Flow When setting up the system for the first time, or when new cameras are added, set up in the manner as follows. Be sure to perform an operation check after the setup. 1 IP address settings Basic Operations of Menu Screen 1 Tap the [SETTINGS] button on the home screen. The settings menu appears. Configure the IP address of the connected device. (A P20 “IP Setup”) 2 Select the item to be configured. Set up the connected camera.
Menu Screen Flow o The menu screens consist of normal menu screen and settings menu screen. The flow of the each screen is as shown in the figures below. Normal Menu Screen VIEW Screen Allows you to select the camera and the preset position of the camera. . Home Screen VIEW Screen CAM Group Screen Settings Position Group Screen Position Screen STORE Screen Allows you to register the preset position of the camera. .
DELETE Screen Allows you to delete the preset position of the camera. . Home Screen DELETE Screen CAM Group Screen Settings Position Group Screen Position Screen F1/F2/F3/USER1/USER2 Screen For assigning functions to the buttons and knobs of this unit. . Home Screen F1/F2 Screen (*) Home Screen F3 Screen (*) USER1/USER2 Screen (*) * You can adjust the function that is highlighted without tapping [ENTER] while the screen is displayed.
Settings Menu Screen SETTINGS Screen For configuring the settings of this unit. (A P15 “Settings Menu”) .
System Setup Switching the Camera Video Output On/Off Setting the video outputs of all cameras on/off 1 Display the home screen. If the home screen does not appear, tap the [HOME] button on the screen. 2 Tap the [SETTINGS] button. 0 Tapping the button changes the button color. 0 Tap the [ON] button to set the video output of the camera to on. Tap the [OFF] button to set the video output of the camera to off. 6 Tap the [ENTER] button to confirm the setting.
IP Setup Network Settings on This Controller Registering the IP Address Settings . 1 Display the home screen. . 1 Display the home screen. If the home screen does not appear, tap the [HOME] button on the screen. 2 Tap the [SETTINGS] button. The settings menu screen appears. 3 Tap the [Network] button. 4 Tap the [CAMERA REGISTRATION] button. 5 Tap the [AUTO] or [MANUAL] button. 0 Tapping the [AUTO] button automatically configures the camera network settings.
Tally Setup Connection example for TALLY OUT Tally Control Interface Configure the pin 4 and pin 5 functions of the tally terminal using the SETTING switch on the rear panel. Other than pin 4 and pin 5, the remaining pin functions cannot be changed. Please ensure the following conditions are met. Voltage : Maximum DC 24 V Current : Maximum 50 mA (Maximum voltage 24 V) RM-LP100 TALLY OUT 1 6 5 9 (Maximum current 50 mA) LED Settings GND .
Troubleshooting Problem Symptom Power does No response even not turn on. after tapping the operation panel on the unit. Action Turn off the power switch at the back of the unit and power on again. If it still does not start up, stop using the unit, disconnect the power cord from the power outlet and consult a dealer or our service center. Others Confirming the “OPEN SOURCE LICENSE” 1 Select [SETTINGS] on the home screen of the operation panel. 0 Tapping the button displays the [SETTINGS] screen.
Specifications Accessories General Item Power Current consumption Mass Surrounding temperature Allowable operating humidity Description DC 12 V 0.6 A Approx. 2.
RM-LP100U/RM-LP100E REMOTE CAMERA CONTROLLER B5A-1936-00 © 2016 JVC KENWOOD Corporation