REMOTE CONTROL UNIT RM-HP790DU RM-HP790DE INSTRUCTIONS REMOTE CONTROL UNIT RM-HP790 TALLY CALL FULL AUTO F3 F1 MENU/SHUTTER GAIN SHUTTER SHUTTER BARS F2 F4 MENU PUSH-ON PAINT WHITE MASTER BLACK AUTO STEP W.BAL HIGH B VARIABLE MID PUSH-ON LOW A R B PRESET POWER IRIS AUTO MANU GAIN INTERCOM LEVEL For Customer Use: Enter below the Serial No. which is located on the body. Retain this information for future reference. Model No. RM-HP790DU Serial No.
Introduction FOR USA These are general IMPORTANT SAFEGUARDS and certain items may not apply to all appliances. IMPORTANT SAFEGUARDS 1. 2. 3. 4. Read all of these instructions. Save these instructions for later use. All warnings on the product and in the operating instructions should be adhered to. Unplug this appliance system from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 5.
Safety Precautions POUR CANADA ATTENTION RISQUE D’ELECTROCUTION NE PAS OUVRIR ATTENTION: FOR USA AND CANADA CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN POUR EVITER TOUT RISQUE D’ELECTROCUTION NE PAS OUVRIR LE BOITER. AUCUNE PIECE INTERIEURE N’EST A REGLER PAR L’UTILISATEUR. SE REFERER A UN AGENT QUALIFIE EN CAS DE PROBLEME. Le symbole de l’éclair à l’intérieur d’un triangle équilatéral est destiné à alerter l’utilisateur sur la présence d’une “tension dangereuse” non isolée dans le boîtier du produit.
Introduction Safety Precautions (continued) IMPORTANT (In the United Kingdom) Mains Supply (AC 230 V) WARNING - THIS APPARATUS MUST BE EARTHED The wires in this mains lead are coloured in accordance with the following code; GREEN-and-YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.
CAUTION: RED color indications on the operation panel are provided but they are not safety related, RED color indications : (1) For Tally Indicator (2) For Calling Indicator WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. WARNING For PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible.
Introduction Safety Precautions (continued) Place of storage and use 䡵 Avoid storing or using the unit in the following places. Failure to do so may lead to malfunction or breakdown. ● Extremely hot or cold places beyond the allowable temperature for operation (-5 f to 40 f) ● Humid or dry places beyond the allowable humidity range for operation (30 % to 80 %) ● Places that generate strong magnetic fields, e.g. transformers or motors ● Places near devices that generate electric waves, e.g.
Sicherheitsvorkehrungen (für Deutschland) SPANNUNGSVERSORGUNG Anschluss am Netz Die Betriebsspannung für dieses Gerät beträgt AC230 V, 50 Hz (RM-HP790DE) ACHTUNG: FÜR DEUTSCHLAND Dieses Gerät entspricht den Bestimmungen und Schutzanforderungen der anwendbaren EU-Richtlinien. Dieses Gerät wurde für professionelle Videoanwendungen entwickelt und kann in den folgenden Umgebungen eingesetzt werden: ● Kontrollierte EMC-Umgebung (z.B. spezielles Rundfunkund Aufnahmestudio) sowie ländliche Außenumgebungen.
Introduction Sicherheitsvorkehrungen (Fortsetzung) Benutzerinformationen zur Entsorgung alter Geräte [Europäische Union] Hinweis: Erklärung zum Rauschen (für die Bundesrepublik Deutschland) : Maschinenlärminformations-Verordunung 3. GPSGV, 06.01.2004: Der höchste Schalldruckpegel beträgt 70 dB (A) oder weniger gemäß EN ISO 7779 Hinweis zum Netzanschlußkabel Zu Ihrer Sicherheit lesen Sie bitte das folgende sorgfältig. Verwenden Sie ausschließlich ein in Ihrem Land zulässiges Netzkabel.
WICHTIGE SICHERHEITSHINWEISE 1. Alle Warnungen auf dem Produkt sowie in der Betriebsanleitung sind unbedingt zu beachten. 2. Ziehen Sie den Netzstecker dieses Systems aus der Steckdose, bevor Sie das Gerät reinigen. Benutzen Sie keine Flüssigreiniger und keine Sprühreiniger. Verwenden Sie zum Reinigen lediglich ein leicht angefeuchtetes Tuch. 3. Benutzen Sie keine Zubehörteile, die nicht vom Hersteller empfohlenen werden; diese können Gefahren und Risiken verursachen. 4.
Introduction Sicherheitsvorkehrungen (Fortsetzung) ACHTUNG 1) Nehmen Sie nicht die Frontabdeckung ab. 2) Falls sich die Frontabdeckung lösen sollte, setzen Sie sie sofort wieder auf. Lager- und Verwendungsort: 䡵 Vermeiden Sie, den Gerät an folgenden Plätzen zu lagern oder zu verwenden. Eine Missachtung kann zu einem Fehler oder einer Störung führen.
How to use this manual Achtung ● Stellen Sie keinerlei Gegenstände auf den RM-HP790DE, wenn dieser in einem Rack montiert ist. Dies kann durch Ungleichgewicht zum Herunterfallen des Geräten führen und Verletzungen oder Schäden verursachen. ● Werden zwei oder mehrere Gerät in dem Rack eingebaut, achten Sie darauf, dass der Abstand mindestens die Größe eines Geräten beträgt. ● Bauen Sie den RM-HP790DE nicht in ein Rack ein, wenn die Umgebungstemperatur 40f oder mehr beträgt.
Introduction Contents Introduction Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Precautions for Proper Use . . . . . . . . . . . . . . . . . . . . . . . . . 3 Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Connection Example of Basic Connection . . . . . . . . . . . . . . . . . . . . . . . 8 Example of Connection with 2 Units . . . . . . . . . . . . . . . . . . 9 Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . .
Precautions for Proper Use 䡵 To prolong the service life of the RM-HP790DU/RMHP790DE, do not use it or store it in the following places. ● A place subject to extremely high or low temperatures. ● A place subject to excessive vibration. ● A place subject to excessive dust. ● A place subject to high humidity. ● A place near to a strong source of noise. 䡵 Do not apply strong vibrations or impact to the RMHP790DU/RM-HP790DE during installation or transportation.
Introduction Names of Parts Front panel A B CD EF I JK M O Q R S T L N P G H U V REMOTE CONTROL UNIT RM-HP790 TALLY CALL FULL AUTO F1 F3 MENU/SHUTTER GAIN SHUTTER SHUTTER BARS F2 F4 MENU PUSH-ON PAINT WHITE MASTER BLACK AUTO STEP W.
L [GAIN-VARIABLE] control with ON/OFF button*2*3 When the button is pressed, the Variable Gain mode is switched AONB and AOFFB alternately. The [GAIN] light M is turned on when the Variable Gain mode is AONB. When the [GAIN] mode is set to AVARIABLEB, the Gain value can be varied from 0.1dB (or 1.0dB) to 18dB in 0.1dB (or 1.0dB) steps. The variation per step and the maximum gain value can be changed under the following items. ( A Page 25 [V. GAIN STEP] and [V.
Introduction Names of Parts (continued) Rear panel 䡵 RM-HP790DU TALLY PGM PVW H C INPUT VIDEO OUTPUT INTERCOM C AUX VIDEO INPUT G GENLOCK INPUT Y/G PB/B OUTPUT PR/R HD/SD SDI A B C REMOTE COMPOSITE VIDEO RTS AC H IN AC120V 60Hz CAMERA CABLE D E AUX VIDEO INPUT GENLOCK INPUT F G H I J 䡵 RM-HP790DE TALLY PGM PVW VIDEO OUTPUT INTERCOM C H C G Y/G PB/B INPUT OUTPUT PR/R HD/SD SDI A B CAMERA CABLE C D E F A [ACHIN] Connector Connect this socket to a commercia
J [CAMERA CABLE] Connector (26-pin) Connect the optionally available camera cables to the camera. Camera Cable (Optional) The VC-P110 series camera cables that can be used to connect a camera to the RM-HP790DU/RM-HP790DE are available in four lengths as listed below. VC-P110 : 5 meters VC-P112 : 20 meters VC-P113 : 50 meters VC-P114 : 100 meters A menu setup is required according to the cables in use.
Connection Example of Basic Connection Standard connection of the RM-HP790DU/ RM-HP790DE (Connection of a single unit) 䡵 When the RM-HP790DU/RM-HP790DE is connected to a camera. Memo : ● When the RM-HP790DU/RM-HP790DE is connected to a camera, a local remote controller cannot be connected to the camera. * 1 When connect the remote control unit cable to the [REMOTE] connector, please be careful to the following points.
Example of Connection with 2 Units 䡵 Standard connection of RM-HP790DU (Connection of 2 units) Memo : ● When the RM-HP790DU/RM-HP790DE is connected to a camera, a local remote controller cannot be connected to the camera. * 1 When connect the remote control unit cable to the [REMOTE] connector, please be careful to the following points.
Connection Example of Connection with 2 Units (continued) 䡵 Standard connection of RM-HP790DE (Connection of 2 units) Memo : ● When the RM-HP790DU/RM-HP790DE is connected to a camera, a local remote controller cannot be connected to the camera. * 1 When connect the remote control unit cable to the [REMOTE] connector, please be careful to the following points.
Rack Mounting Turning the Power ON Mount this unit to the EIA rack. 1 Remove the screws A on the four stands at the bottom Remove the stands. 1 Connect the camera to the RM-HP790DU/RM-HP790DE using a proper connection method 2 Press the [POWER] switch of the RM-HP790DU/RMHP790DE to ON 2 Mount the unit to the rack using the screws B Secure to the rack with the optional screws x4 (M5 x 10 mm) REMOTE CONTROL UNIT RM-HP790 . PAINT WHITE POWER IRIS MASTER BLACK AUTO W.
Preparations and Main Functions Camera Cable Length Setup Adjustments for Genlock Operation Cable length setup is required when a camera is connected to the RM-HP790DU/RM-HP790DE for the first time or when the camera cable length is changed. The cable length setup value is stored in the memory inside the RM-HP790DU/RM-HP790DE and is held even after it is turned OFF. FULL AUTO F1 F3 MENU/SHUTTER GAIN SHUTTER P STEP HIGH 2.
Adjusting the H PHASE Adjusting SC phase (Only for SD signal)*1 1 Press and hold the [MENU] button for about 3 seconds until the LCD display shows the menu display Cursor *1 This function is unavailable when connected to GY-HM790 series.
Preparations and Main Functions Intercom Camera Operator Call Intercommunications between operators are necessary in a system composed of multiple cameras and remote control units. This function makes it possible to call the camera operator without using the intercom. The camera operator is informed of the call by the blinking of the tally lamp on the camera. 䡵 The factory settings vary depending on the model.
2 When the [F1] button is pressed again, the [BLACK Function Buttons STRETCH] function is switched from ON to OFF and the light in the button turns off FULL AUTO Up to four of the functions listed at the bottom of this page can be assigned to function buttons [F1] to [F4] so that each function can be switched on or off by pressing the corresponding button. (For the assignment of functions: A Page 25 [FUNC1] to [FUNC4] in the [OPERATION Menu].
Camera Adjustments Shutter Speed Adjustment Turning the [SHUTTER] control knob can vary the shutter speed of the camera. The LCD display shows the shutter speed during the adjustment operation. Memo : ● When the FAS (Full Auto Shooting) is ON, the shutter speed becomes EEI. However, the shutter speed is OFF in the Lolux mode. ● When FAS is ON, the [SHUTTER] control knob cannot be used to vary the shutter speed. ● When [ALC + EEI] is ON, the shutter speed becomes EEI.
Gain Adjustment Iris Adjustment When the illumination of the object is insufficient, the electrical gain can be boosted as described below. The camera lens iris can be adjusted from the RM-HP790DU/RM-HP790DE. Memo : Memo : ● When the [FULL AUTO] or [ALC + EEI] is ON, the gain becomes ALC. However, the Gain is Lolux in the Lolux mode. The gain cannot be varied in this mode.
Camera Adjustments White Balance Adjustment White paint operation This can be performed after completion of the auto white balance adjustment and enables the fine adjustment of the white balance using the [R] and [B] gain controls. Since color temperature varies depending on the light source, the white balance should be adjusted whenever the main light source illuminating the object being shot changes.
Menu Operation Memo : Flow of Menus ● The items and values that are not available with the camera are not menus displayed. The menus displayed on the RM-HP790DU/RM-HP790DE are provided in the form shown below.
Menu Operation 6 Press the [SHUTTER] control knob to move the cursor Menu Setup Method (J) back to the item 2A: LENGTH 100M Each menu is displayed on the LCD display and can be set up using the [MENU] button and the control knob. The values set in the [4: PROCESS] and [5: OPERATION] menus can be saved in files A, B, C and D.
GENLOCK Menu This menu is used to set the camera cable length to the length actually used. (A Page 12 [Adjustments for Genlock Operation]) * Default values are indicated in bold characters. No. Item Setting Values Function 1A SD H PHASE *1 -128 to 0 to 127 1B HD H PHASE -1024 to 0 to 1023 Adjustment of the Horizontal sync phase of genlocking. 1C SC COARSE *1 0⬚, 90⬚, 180⬚, 270⬚ Coarse adjustment of the color phase of genlocking. Use a vectorscope, etc.
Menu Operation 5 Press the [SHUTTER] control knob again to move the FILE Menu cursor (J) to AAB 3B: STORE FILE A The values set with the menu and applied to the RM-HP790DU/RM-HP790DE can be saved in four files named A, B, C and D.
PROCESS Menu This menu sets the functions built into the camera. * Default values are indicated in bold characters. Memo : ● Functions not available on the camera cannot be controlled from this unit. No. Item Setting Values Function 4A DETAIL OFF ON 4B DETAIL LEVEL -10 to NORMAL to 10 Adjusts the detail enhancement level. Increasing the level : Sharpens details. (21 steps) Decreasing the level : Softens details.
Menu Operation PROCESS Menu (continued) * Default values are indicated in bold characters. No. Item Setting Values Function 4J GAMMA OFF ON 4K GAMMA LEVEL -10 to NORMAL to 10 Adjusts the gamma correction level. Increasing the level : Improves the reproduction of black but leads to loss of gradation of white. Decreasing the level : To be used when the reproduction of black is not strongly required.
OPERATION Menu This menu sets the functions built into the RM-HP790DU/RM-HP790DE. * Default values are indicated in bold characters. No. Item 5A SHUTTER 5B Setting Values Function STEP VARIABLE Selects whether the front panel [SHUTTER] control varies the shutter speed in steps or in fine variation. STEP : Shutter speed variation in steps. VARIABLE : Fine, continual variation to be used when shooting a computer monitor, etc. V. GAIN STEP *1 1.0 dB 0.
Menu Operation LCD MODE Menu This menu sets up the LCD display. * Default values are indicated in bold characters. No. Item Setting Values Function 6A CONTRAST -5 to NORMAL to 5 Adjusts the contrast of the LCD display. 6B BACKLIGHT OFF ON Adjusts the setting of the backlight of the LCD display. OFF : Backlight is turned off. ON : Backlight is turned on. 6Z BACK ^ Return to the previous display. SYSTEM Menu This menu performs setting regarding System.
5 If you want to reset the values, turn the [SHUTTER] control knob to move the cursor (J) to AEXECUTEB ANOW INITIALIZINGB and AJUST A MOMENTB will be displayed during SYSTEM RESET. 7A: SYSTEM RESET EXECUTE Initial values ● The values you’ve set in the menu items will be reset to the initial values shown on pages 21 to 26. ● Other status settings are reset as shown below. Status Setting Default values [IRIS-AUTO/MANU] button [MANUAL] NOW INITIALIZING [W.
General Warning Messages To prevent operational errors, the LCD display shows one of the following warning messages when an erroneous operation is performed. Displayed Message Cause Check Point INVALID ENTRY GAIN : LOLUX The gain is set to the Lolux mode. Exit from the Lolux mode, and then adjust the gain again. INVALID ENTRY FULL AUTO : ON The [FULL AUTO] button is ON. Press the [FULL AUTO] button so that the lamp in it turns off, then retry operation.
GY-HM790 series Operable Camera Features Function BARS GY-HM790 series Function IRIS 3: Available -: Not available AUTO IRIS AI LEVEL 3 MANUAL IRIS 3 IRIS LEVEL MANUAL PRESET DETAIL FRQ*1 AUTO KNEE 3 3 AUTO1 3 AUTO2 3 FAW 3 - WHITE 3 MANUAL LEVEL R, B 3 COLOR MATRIX GAMMA GAIN 3 3 3 LOW 3 MIDDLE 3 HIGH 3 AUTO - OFF 3 ON 3 3 OFF - ON - OFF 3 ON 3 BACK 3 ASPECT RATIO - DNR 3 FAW 3 SMOOTH TRANS -3 dB 3 3 ON 3 DNR LEVEL 0 dB 3 OFF GAMMA LEVEL WHIT
General Operation of Connected Camera Menu items that are disabled Menu Page When RM-HP790DU/RM-HP790DE is connected to a camera, all features that are available on RM-HP790DU/RMHP790DE can only be controlled by RM-HP790DU/RMHP790DE, and control of these features using the camera is disabled. Switches on the camera that are disabled, as well as disabled menu items are as follows.
Troubleshooting Symptom Colors in the monitor screen are abnormal. (During genlocking) Video Synchronization is not possible. troubles Pressing the corresponding button cannot start the operation. AB is displayed on the LCD.
General Specifications Input Signals Tally Output Signals RM-HP790DU : Contact supply : DC 10 V, 3 mA or more RM-HP790DE : Voltage supply : AC 6.3 V, DC 5 to 24 V Non-switching between AC and DC Intercom Composite video signal : 1 V (p-p), 75 K, 1 output R/G/B signals : 0.7 V (p-p), 75 K, x1 each (without sync) Y/PB/PR signals Y : 1 V (p-p), 75 K PB : 0.7 V (p-p), 75 K PR : 0.
General Input Voltage RM-HP790DU : AC 120V, 60 Hz RM-HP790DE : AC 230V, 50 Hz Power Consumption (Consumed current) RM-HP790DU : 80 W (GY-HM790 series+KA-M790G+ VF-HP790G+RM-LP25U+Headset) RM-HP790DE : 0.4 A (GY-HM790 series+KA-M790G+ VF-HP790G+RM-LP25U+Headset) Mass : Approx. 5.
RM-HP790DU/RM-HP790DE REMOTE CONTROL UNIT 2010 Victor Company of Japan, Limited LST1153-001A