REPORT No.SZ19050315S01
Maximum Power Tune-up Tolerance
This device is a Clarion Module (Model name: Clarion Module R9, FCC ID: 2ADEK1905R9),
description of Tune-up Tolerance:
1 Per KDB 447498 D01v06, the maximum output power channel is used for SAR testing and for
further SAR test reduction.
2 The EUT was connected to Base Station R&S CMW500/MT8820C referred to the Setup
Configuration. For the maximum power, it was established between EUT and Base Station with
following setting:
1) For GSM/GPRS testing, the MS TX Level was set 5 for low frequency bands and 0 for high
frequency bands.
2) For LTE testing, Power Ctrl Mode = All 1, and the transmitted maximum output power was
recorded.
Maximum Power Tune-up Tolerance:
Technology/Band
Mode
Target Power and Tolerance
(dBm)
GSM 850
EDGE 1Tx slot
24.0±1 dBm
EDGE 2Tx slot
24.0±1 dBm
EDGE 3Tx slot
23.5±1 dBm
EDGE 4Tx slot
23.0±1 dBm
GSM 1900
EDGE 1Tx slot
24.0±1 dBm
EDGE 2Tx slot
24.0±1 dBm
EDGE 3Tx slot
23.5±1 dBm
EDGE 4Tx slot
23.5±1 dBm
LTE Band 2
QPSK
22.5±1 dBm
LTE Band 4
QPSK
21.5±1 dBm
LTE Band 5
QPSK
22.0±1 dBm
LTE Band 12
QPSK
22.0±1 dBm
LTE Band 18
QPSK
22.0±1 dBm
LTE Band 19
QPSK
22.0±1 dBm
LTE Band 26
QPSK
21.5±1 dBm
LE
GFSK
-2.5~0.5dBm