Congratulations on your purchase of a JTECH Kitchen Messaging System containing the IntelFlex Kitchen Controller. Please take a few minutes to review this manual prior to installing and operating your system. Please inspect the System upon receipt. If the contents appear to be damaged, notify the shipper immediately to file a claim and notify JTECH Customer Care. If components are missing, contact JTECH Customer Care.
DC Operating Voltage: Power Adapter Transmitter Power Output:: Keypad Display: Modulation: Protocol: Transmit: 13.5VDC 2.4A 110-240VAC 50-60Hz power adapter 0.1-2 Watts - adjustable using 5 levels. 20 Button LED FSK 512 BPS POCSAG 512. 1200, 2400 Baud Kitchen System with Clamp Bracket Dimensions 11-3/8” (288.9mm) 7-9/16” (192.1mm 3-3/16” (81mm) C ft ra D 1/8 - 2 1/16” (3.2-52.4mm) op y 9-5/16” (236.4mm) 6-7/8” (174.6mm) 7-5/16” (185.7mm) 16-5/16” (413.
50 ohm BNC 6” (153mm) Rotating Whip Stainless Steel” UHF synthesized 450-470 MHz. (standard) -22°to 122°F (-30 to 50°C) at better than 5 ppm 2.5-3.0 Lbs (1.14-1.36Kg) -Depending on Mounting Brackets used. 1.85-2.35Lbs (0.84-1.1.07Kg) -Depending on Brackets Used. Weight: (Keypad Only) Mounting Kitchen System with Wall Bracket Dimensions 4 Mounting Slots for 1/4” (6-7mm) Diameter Screws or Bolts ft D ra 3-3/8” (85.7mm) 5 –11/16” (144.5mm) System Dimension C 8-1/8” (206.4mm) op y 1-7/16” (36.
Kitchen System with Wall Bracket Dimensions 6-7/8” (174.6mm) 7-9/16” (192.1mm) 12” (304.8mm) op y C Left Side View Right Side View ra ft Front View (With Clamp Mount Bracket) D System Dimension 9” (228.6mm) 6-7/8” (174.
IntelFlex Kitchen System Highlights • Designed for used in restaurant kitchens and similar applications. • Available in 20, 40 and 60 button systems with 20 buttons per Panel. • Connect additional panels for Expeditor or Server Cancel functions. • Page up to 60 Wait Staff Pagers and one or more op y Manager Pagers at any time (depending on programming). programmable length of time. C • Use the Controller’s 2X or 3X buttons to ft change the number of vibrations sent to the Wait Staff’s Pagers.
Expeditor or Server Cancel Panels (Optional) op y Optional Panels Panels: Additional Panels can be connected to the Controller. The Panels can then be programmed for cancel or expedite modes. C • Require Wait Staff to cancel their page at the Cancel Panel. ft • Continue to repeat the page after a specific period of time, until the Wait Staff cancels their page.
• Grease Pencil : Used to write the staff’s names on the Magnetic Templates, use a Grease Pencil. One is supplied with the Kitchen Controller or Cancel/Expeditor Panel. Using other types of markers may permanently stain these Panels. Use a soft cloth and rubbing alcohol to erase Grease Pencil marks. • Magnetic Templates: Damaged or scratched templates can be replaced as needed . • USB Keyboard: Attach a Keyboard to the Controller to send a alphanumeric page to Managers Pagers.
All Extended Range Antenna choices require FCC approval and licensing. JTECH can assist in acquiring any additional licensing. Magnetic Mount Antenna with 12ft (3.6m) Cable: All metal indoor/outdoor Antenna with a magnetized base for mounting to steel or iron. Wall mounting hardware include for wall mounting to non magnetic surfaces. • 6ft (1.8m) Antenna and 25ft (7.6m) Cable: Fiberglass indoor/outdoor Antenna which can mount to any stable surface. Wall mounting hardware included.
• Use Vibe or Vibe/Tone Rechargeable Pagers (Wait Staff) to receive a page from the Kitchen Controller or Expeditor Panel. Vibe/Tone Pagers Pagers That Work with the IntelFlex Kitchen Controller • Use Alphanumeric (Managers) Pagers to received ft C numeric information from the Kitchen Controller, Cancel Panel, Expeditor Panel or Managers Button. Adding a Keyboard to your Kitchen Controller allows the user to send alphanumeric messages.
Installing the Kitchen Controller and Cancel/Expeditor Panel • Mount on a wall, clamp to a shelf or let it sit on any flat surface. with the antenna tip at least 18” away from any metal. This includes; counters, backsplash, etc. • Walls, pipes, ducts, mirrored glass, etc. op y may weaken or misdirect transmitted signals. • Locate away from liquids or extreme ft C heat. • The Antenna must be mounted ra vertically.
D ra ft C op y Assembly for Stand Bracket Shelf, Table or Counter Top Stand Bracket Clamp Brackets Assembly for Clamp Brackets Shelf, Table or Counter Top Mounting Wall Bracket Assembly for Wall Bracket Walls or Vertical Surface Wall mounting screws are not supplied. Select wall mounting hardware as needed.
Powering the Transmitter Powering the Kitchen Controller 1. Connect the Power Adapter to the Kitchen Controller and plug it into a 120VAC outlet. 2. The Controller LED’s will light in a sequence, TRANSMIT light will light and the POWER light will flash. 3. After several seconds, the TRANSMIT light turns off and the Kitchen Controller is ready for use. 4. The POWER light continues to blink while the system is powered.
Connecting the Cancel or Expeditor Panel with Managers Button 1. The Cancel/Expeditor Panel must be connected to the Kitchen Controller Panel before connecting power. 3. Plug the Phone Cord into the gray “REMOTE” jack of the Controller Panel and into the gray “REMOTE” jack of the Cancel/Expeditor Panel. 4. Plug 1 end of the RJ-12 100’ (30m) Cable into the Kitchen Controller Panel “EXPANSION” jack and the other end into the Managers Button. • Do not use the Managers Button as a power source.
Connecting a 40 Button System with Cancel/Expeditor Panels Managers Button 1 ra ft C op y Expansion Panel Buttons 21-40 D Connecting a 40 Button System with Cancel/Expeditor Panels Kitchen Controller Buttons 1-20 Cancel/Expeditor Panel Buttons 1-20 Cancel/Expeditor Panel Buttons 21-40 All Expansion Panels connect together using the supplied 1’ (0.3m)Cables.
Connecting a 60 Button System with Cancel/Expeditor Panels Expansion Panel Buttons 41-60 Managers Button 1 D ra ft C op y Expansion Panel Buttons 21-40 Cancel/Expeditor Panel Buttons 1-20 Cancel/Expeditor Panel Buttons 21-40 Cancel/Expeditor Panel Buttons 41-60 Managers Button 2 Connecting a 60 Button System with Cancel/Expeditor Panels Kitchen Controller Buttons 1-20 All Expansion Panels connect together using the supplied 1’ (0.3m)Cables.
Range Testing op y When the Controller is put into Range Test Mode, it will continue to send a page every 3-4 seconds for 4 minutes. This will allow a person to walk the area where your Pagers will be used and check for dead spots or weak signal areas. If you find such areas, try relocating the Controller. C 1. Wear any Wait Staff Pager as usual, do not hold the Pager in your hands. 2. The Pager selected will vibrate during the range test. ft 3. Press and hold the program button for 2 seconds.
Paging using a Controller or Expeditor Panel 2. The light on the Panel, next to that number will turn ON. 3. The TRANSMIT light will turn ON for 2-3 seconds and turn off. 4. The Pager will receive a single, one second vibration (factory setting) or: A. Send double or triple vibrations individually at any time by pressing 2X or 3X button before pressing the Pager button. The Controller must be programmed for single vibration (factory setting) for these buttons to work as described. B.
Using the Cancel Panel • The Cancel Panel is used to cancel (end) pages sent from the Controller. • After the Controller sends a page, the Wait Staff must cancel (end) the page by pressing the Pager number button on the Cancel Panel. • If not canceled, the Controller will continue to • The delay between repeat pages is 40 seconds (factory setting) and can be adjusted by changing the program settings. • When a page is sent; op y 1.
Paging from a IntelFlex Desktop Controller Page Wait Staff from a IntelFlex Desktop Controller ft 2. Press # or “SEND”. C 1. From the Desktop Controller press “90NN” where NN = the Wait Staff Pager number. D ra 3. That Pager will receive a alert of 16 short vibrations.
Factory Settings Standard Program Settings Factory Settings: Unless ordered otherwise, the factory defaults are: • Pick Up Period: = 40 seconds • All Call: = Selected • Remote Panel Setting = Expedite mode • Number Of Vibrations = Single Vibration • Transmit Power = 2 Watt (Maximum) Press and hold the PROG on the Controller Panel for 2 seconds. 2. LED’s 1-7 will blink. 3. Press button 3. 4. The current setting will blink and the remaining LED’s will light. Each button = its value X 10 seconds.
The Panel can be programmed as a Cancel or Expeditor Panel and cannot be both at the same time. A Cancel Panel is used by the Wait Staff to cancel their pages after picking up an order. A Expeditor Panel is used by an Assistant or Chef to page the Wait Staff. To program: 1. 2. 3. 4. Press and hold PROG on the Controller for 2 seconds. LED’s 1-7 will be ON. Press button 1. LED’s 1-2 will light with the current choice blinking; 1= Cancel, 2=Expedite. 5. Press button 1 (Cancel) or 2 (Expedite) as needed. 6.
Service Assistance For assistance, please contact JTECH Customer Care at 800-321-6221, fax at 561-995-2260 or email at wecare@jtech.com . JTECH provides complete diagnostic technical support 24 hours a day, 7 days a week. Warranty op y C Billing for Repairs Terms are C.O.D. (company check), company billing or credit card. If “advanced replacement” is required, replacement equipment will arrive with a packing list and a Return Material Authorization Sheet (RMA).
General Terms and Conditions This offer is subject to the terms and conditions listed below which are binding upon the D ra ft C op y 1. Price. All prices are F.O.B. point of origin, unless otherwise agreed to in writing by the buyer and seller. Prices quoted are those in effect at the time of quotation and are valid for 30 days from the date of quotation regardless of existence of any written confirmation.
op y C ft ra D General Terms and Conditions 26 regulations or export control imposed by the U. S. Government. 12. Delays. Unless specified in writing by JTECH to the contrary, goods in stock shall be shipped immediately upon the signing of a binding purchase agreement. Goods not in stock will be shipped as soon as possible.
FCC RF Exposure Statement Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
SYSTEM WARRANTY JTECH Communications, Inc. warrants its equipment to be free from defects in materials and workmanship for a period of one year. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and date and place of purchase.