Operating Instructions and Parts Manual Electrostatic Air Filtration System Electrostatic AFS Model: PM1250 Remote control Model: PM1250-R This product earned the ENERGY STAR® by meeting strict energy efficiency guidelines set by the US EPA. US EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product.
11. Do not place this unit on an unstable surface, or where there is a risk of tipping over. Serious injury could occur if the unit tips over. 12. Do not use this air filtration unit with a damaged cord or plug. If the unit is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center. 1.0 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following: 13.
WARNING: Some dust, fumes and gases created by power sanding, sawing, grinding, drilling, welding and other construction activities contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Some examples of these chemicals are: • lead from lead based paint • crystalline silica from bricks, cement and other masonry products • arsenic and chromium from chemically treated lumber Your risk of exposure varies, depending on how often you do this type of work.
2.0 Table of contents Section Page 1.0 IMPORTANT SAFETY INSTRUCTIONS ....................................................................................................... 2 2.0 Table of contents ............................................................................................................................................ 4 3.0 About this manual .......................................................................................................................................... 4 4.
4.0 PM1250 Electrostatic AFS specifications Table 1 Stock number Model number 1791331 PM1250 3 1, 2, 4, 8 50.8 dBA ±10% 45.0 dBA ±10% 41.
The specifications in this manual were current at time of publication, but because of our policy of continuous improvement, Powermatic reserves the right to change specifications at any time and without prior notice, without incurring obligations. 4.
Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the tool's plug. 5.0 Electrical connections Electrical connections should be made by a qualified electrician in compliance with all relevant codes. Failure to comply may cause serious injury. Repair or replace immediately. damaged or worn cord 2.
6.0 Unpacking 6.1 Shipping contents Open shipping cartons and check that all parts are intact. Report any damage or missing parts to your distributor. Note that your unit may be provided with extra fasteners. Read the instruction manual thoroughly for assembly, alignment, and maintenance instructions. 1 2 1 1 2 6 4 1 1 1 5. Unit will count down from the corresponding time, and will automatically shut off at time expiration. 9.
To remove filter: 9.2 Anion generator maintenance 1. When filter life reaches programmed time (1000 hours), red Reset indicator light will flash twice per second. Remove dust regularly from the anion generator (i.e. carbon brush) with the provided cleaning brush. See Figure 9-1. 2. Turn off unit. CAUTION: The internal metal ring carries an electrical charge during operation. Turn off unit before attempting to remove cover. 3. Rotate cover counterclockwise and remove it, along with the prefilter.
Figure 8-1: Assembly Figure 8-2: Controls Figure 8-3: Remote control (Model: PM1250-R) Figure 8-4: Filter replacement 10
10.0 Troubleshooting PM1250 Electrostatic AFS Table 4 Symptom Machine will not start. Excessive vibration. Unit not responding to remote control. Unit not working efficiently; not cleaning air. Controls on unit not working. Probable Cause Remedy* No incoming power. Check plug connection. Cover improperly installed. Reinstall cover. If properly installed, red light will illuminate on control panel. Low voltage. Request voltage check from power company and correct low voltage condition.
11.0 Replacement parts To order parts or reach our service department, call 1-800-274-6848 Monday through Friday, 8:00 a.m. to 5:00 p.m. CST. Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately. Non-proprietary parts, such as fasteners, can be found at local hardware stores, or may be ordered from Powermatic. Some parts are shown for reference only, and may not be available individually. 11.1.
11.1.
12.
13.0 Warranty and Service Powermatic® warrants every product it sells against manufacturers’ defects. If one of our tools needs service or repair, please contact Technical Service by calling 1-800-274-6846, 8AM to 5PM CST, Monday through Friday. Warranty Period The general warranty lasts for the time period specified in the literature included with your product or on the official Powermatic branded website. • Powermatic products carry a limited warranty which varies in duration based upon the product.
427 New Sanford Road LaVergne, Tennessee 37086 Phone: 800-274-6848 www.powermatic.