Operating Instructions and Parts Manual AFS-1000C Air Filtration System JET 427 New Sanford Road LaVergne, Tennessee 37086 Ph.: 800-274-6848 www.jettools.com Part No.
1.0 IMPORTANT SAFETY INSTRUCTIONS 15. When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS AIR FILTRATION UNIT. To reduce the risk of fire, electric shock, or injury: 1. Read and understand the entire owner's manual before attempting assembly or operation. 2. Read and understand the warnings posted on the machine and in this manual. Failure to comply with all of these warnings may cause serious injury. 3.
WARNING: Some dust, fumes and gases created by power sanding, sawing, grinding, drilling, welding and other construction activities contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Some examples of these chemicals are: • lead from lead-based paint • crystalline silica from bricks, cement and other masonry products • arsenic and chromium from chemically treated lumber Your risk of exposure varies, depending on how often you do this type of work.
2.0 Table of contents Section Page 1.0 IMPORTANT SAFETY INSTRUCTIONS ....................................................................................................... 2 2.0 Table of contents ............................................................................................................................................ 4 3.0 About this manual .......................................................................................................................................... 5 4.
3.0 About this manual This manual is provided by JET, covering the safe operation and maintenance procedures for a JET Model AFS1000C Air Filtration System. This manual contains instructions on installation, safety precautions, general operating procedures, maintenance instructions and parts breakdown. Your machine has been designed and constructed to provide consistent, long-term operation if used in accordance with the instructions as set forth in this document.
4.
5.0 Specifications Table 1 Model No. AFS-1000C Stock No. 713000 SPECIFICATION Motor: Motor type BLDC (Brushless Direct Current Motor) Horsepower 1/3HP Phase 3PH Electrical: Voltage 120V input, single phase only Frequency 60Hz Listed FLA (full load amps) 3.
Table 1 (cont.) Dimensions and Weight: 1 Overall Dimension (L x W x H / in) 30 x 24 x 15 / in Packing Dimension (L x W x H / in) 33 x 27 x 19 / in Packing Material Corrugated Box and Styrofoam Net Weight (lbs.) 33Ibs (15 kg) Gross Weight (lbs.) 41.8lbs (19 kg) Variable of ±10%, for general information only, not to be viewed as fixed parameters for inspection purposes.
6.4 Installation Read and understand the entire contents of this manual before attempting assembly or operation. Failure to comply may cause serious injury. 6.4.1 Overhead (ceiling) Overhead structure (often ceilings) must be capable of supporting the weight of the air filtration unit and absorbing any vibrations arising from the unit. Appropriate fasteners must be used to secure to the ceiling. Failure to comply may cause serious injury. Never mount to surfaces such as dry wall, false ceiling grids, etc.
7.0 Electrical connections Electrical connections should be made by a qualified electrician in compliance with all relevant codes. Failure to comply may cause serious injury. The AFS-1000C Air Filtration System is prewired for single phase, 120V power. It is provided with a plug designed for use on a circuit with a grounded outlet that looks like the one pictured in Figure 7-1. Figure 7-1 It is recommended that the AFS-1000C be connected to a 15 amp circuit with a circuit breaker or fuse.
When the Power switch (Fig. 8-1, A) is first turned ON, power is supplied to the electronics and the AFS unit is in the STANDBY state. All DISPLAYs are off. 8.0 Controls Functions 8.1 Control Panel Buttons Each press of the ON/OFF button (Fig. 8-1 and 8-2, B) cycles the AFS unit between STANDBY and ON. B Pressing the ON/OFF button once: A Figure 8-1 8.2 RF Remote Control • AFS Unit goes to ON state. • The TIMER DISPLAY is blank. • The fan starts to run at speed 1.
FAN SPEED ADJUSTMENT (control panel or remote) In AUTO mode, the integrated sensor detects the air quality and adjusts the fan speed accordingly. Thereby reducing energy consumption when air quality is good and increasing the fan speed when dust is present. The SPEED Buttons (Fig. 8-1 and 8-2) on the controls and the remote perform the exact same function under the exact same conditions. • The SPEED display uses illuminated bars to indicate which speed level is active.
10.0 User-maintenance 10.2 Cleaning the Filters Always disconnect power to the machine before performing maintenance. Failure to do this may result in serious personal injury. To reduce the risk of injury, disconnect the air filtration system from the power source (unplug) before servicing or changing filters. Failure to comply may cause serious injury! 10.1 Changing the Filters This AFS is designed to remove airborne nonmetallic dust particles from the air.
• Allow all excess water to drain off the filter. While the filter does not need to be absolutely dry, do not return to service if water is dripping or droplets are still visible. • Low pressure compressed air may be used to remove any remaining water from the filter. • Install the filters in reverse of the removal. The outer filter has directional air flow arrows printed on the frame which depicts the direction of air flow. Make sure it is facing the proper direction when installed.
11.0 Troubleshooting Table 4 Symptom Probable Cause Remedy Power ON/OFF switch in the OFF position Move Power ON/OFF switch to the ON position. No incoming power Check plug connection Verify there is power at the outlet, check breaker or fuse panel. Low voltage Request voltage check form power company and correct low voltage condition. Power cord damaged Replace power cord. Control button or PCBA malfunction Contact JET customer service.
12.0 Replacement Parts Replacement parts are listed on the following pages. To order parts or reach our service department, call 1-800274-6848 Monday through Friday, 8:00 a.m. to 5:00 p.m. CST. Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately. 12.1.
12.1.2 AFS Unit – Parts List Index No Part No Description Size Qty 1 ................ AFS1000C-001 ......... Motor........................................................................ ..................................... 1 2 ................ AFS1000C-002 ......... Fan blade (Right) ..................................................... ..................................... 1 3 ................ AFS1000C-003 ......... Fan blade (Left) ....................................................... ............
12.2.1 Display Module Assembly – Exploded View 12.2.2 Display Module Assembly – Parts List Index No Part No Description Size Qty 8 ................ AFS1000C-DMA ....... Display Module Assembly........................................ ..................................... 1 8-1 ............. AFS1000C-DM1 ........ AC power switch ...................................................... ..................................... 1 8-2 ............. AFS1000C-DM2 ........ Display label .............................
12.3.1 Remote Control Assembly – Exploded View 12.3.2 Remote Control Assembly – Parts List Index No Part No Description Size Qty 20 .............. AFS1000C-RCA ........ Remote Control Assembly ....................................... ..................................... 1 20-1 ........... AFS1000C-RC1 ........ Remote label............................................................ ..................................... 1 20-2 ........... AFS1000C-RC2 ........ Remote front case .........................
CN1 CN2 Display PCB Dust Sensor Power Switch CN2 Control Module Power Cord Thermal Fuse Motor 13.
14.0 Warranty and service JET warrants every product it sells against manufacturers’ defects. If one of our tools needs service or repair, please contact Technical Service by calling 1-800-274-6846, 8AM to 5PM CST, Monday through Friday. Warranty Period The general warranty lasts for the time period specified in the literature included with your product or on the official JET branded website. • JET products carry a limited warranty which varies in duration based upon the product.
NOTES 22
NOTES 23
427 New Sanford Road LaVergne, Tennessee 37086 Phone: 800-274-6848 www.jettools.