T-1000 Smart THERMOSTAT Installation Manual
Thank you for inviting H2O Degree into your home. The setup process is easy. All you need to do is follow these simple steps and you’ll be on your way to saving energy and making your home even more comfortable. H2O Degree offers installation and product videos Please visit h2odegree.com/videos or visit our YouTube channel H2O Degree. Note: To contact H2O Degree technical support, please call (215) 7888485 or email info@h2odegree.com.
1. START HERE What’s in the box? T-1000 Smart Thermostat Trim Plate Wiring Labels Screws Wall Anchors Batteries Phillips Screwdriver Optional: Wire Stripper Tools Needed Drill Table of Contents 1. Start Here.......................................................................................2-5 2. Installing T-1000............................................................................6-10 3. Operating T-1000 .......................................................................11-14 4.
This manual is a comprehensive guide for the installation and wiring of your H2O Degree T-1000 thermostat. Step 1.1: Turn off the power at the circuit breaker to both your heating and cooling systems before performing any wiring. STOP Step 1.2: Confirm that your heating and cooling system is powered down by changing the temperature on your existing thermostat. The heating and cooling should not come on but may show the temperature change on your existing thermostat.
1. START HERE Step 1.4: Take a picture of your current wiring layout. The picture can be used as reference later. Step 1.5: Use the included wire labels to mark which wire is connected to each terminal in your old thermostat. Note: Wiring letter designations correspond to either a “Heat Pump” or “Conventional” system. H2ODegree.
Wiring Step 2.1: Identify your system configuration (see wiring diagrams in appendix).
INSTALLATION 2. WIRING Step 2.2: Verify that each wire has been properly labeled and remove each wire from its terminal — make sure that they don’t fall into the wall. Step 2.3: Remove the mounting screws from the base of the old thermostat and remove the base from the wall. Step 2.4: Separate the T-1000 from its base. Step 2.4 Step 2.5: If you would like to use the trim plate or wall anchors, you may install them now. Step 2.6: Pull the wires from your wall through the center hole of the T-1000 base.
Option 1 - Conventional (furnace) Systems: Step 2.7f: Follow the terminal labels marked “Conventional” on the thermostat base. Press the lever and insert each labeled wire into the top hole of the corresponding terminal. CONVENTIONAL HEAT PUMP POWER BRIDGE C Y1 W2 C Y1 O/B 4 Step 2.8f: If you have both an RC and RH wire present, then remove the red cap next to the reset button. You can now proceed to step 2.9. Option 2 - Heat Pump Systems: Step 2.
INSTALLATION 2. WIRING Wiring Step 2.9: If you do not have a C-wire, insert the (4) AA batteries included with your T-1000 thermostat according to their correct polarization markings found on the T-1000. Securely fasten T-1000 onto its base. Once it has clicked into place, return power to your heating and cooling system. Note: If batteries are installed, you must replace all batteries with only premium brand alkaline batteries at least once every two years.
Step 2.10: Your T-1000 is now ready to be configured for your heating and cooling system. The T-1000 will guide you through the initial system configuration. Use the knob to change options and press the knob to confirm your selection. First you will need to set your system type: (F) for Furnace or Boiler: Set the fan type to Gas (most common), Electric (for systems without gas or oil), or Boiler (no fan).
OPERATIONS GUIDE Changing T-1000’s Décor-snap™ Cover Place right hang on outside edge of the Décor-snap cover and left hang on the edge of the T-1000 screen. Hold T-1000 in place while gently pulling the decor snap cover. You will find important information for H2O Degree network setup inculding ZigBee Intall Code and model number. 3. OPERATIONS The operations guide section covers the following: • 3.1 How to use T-1000 • 3.2 Reading T-1000’s screen • 3.3 Using T-1000 throughout the year 3.
3.2 Reading T-1000’s screen The large number in the top left shows your ambient room temperature. The small number in the bottom right shows your set temperature. The selected system mode (HEAT, COOL or OFF) is shown to the right of the ambient room temperature. The active fan status is shown by the icon below the ambient room temperature. If it is off, your fan is not running. If it is on, your fan is running. Please note that your fan will run depending on your selected fan mode (either AUTO or ON).
OPERATIONS GUIDE 3. OPERATIONS Reading T-1000’s screen This icon opens the system mode menu. In this menu, you can set your HVAC system to OFF, HEAT, or COOL. Your thermostat will automatically detect which modes are available when you install your thermostat, so you may not see all three options depending on your system type. This icon opens the fan mode menu. In this menu, you can set your fan to AUTO, or ON. AUTO will run your fan when your system is actively heating or cooling.
This icon opens the H2O Degree network connection menu. In this menu, you can choose to connect the H2O Degree network. Select “SET” to establish a new network connection. For more information about connecting to the H2O Degree network call technical service at (215) 788-8485 3.3 Using T-1000 throughout the year Cold Weather: Heat mode is the best setting to use when it’s cold out and you won’t need to use your air conditioner.
4. APPENDIX Conventional System Fan RC RC G G Conventional Heat Pump 1 Power Bridge Heat (Stage 1) Heat (Stage 2) Cool C C 4 Y1 W2 W1 RH Y1 O/B W1 RH 2 3 Conventional Heat Pump Power Bridge Transformer Furnace Thermostat Notes: • C-wire optional • The W2 terminal is used for 2 stage heating • If you have both an RH and RC wire, please remove the red cap from the back of the thermostat H2ODegree.
Heat Pump System Fan RC RC G G Conventional Heat Pump 1 Power Bridge AUX/Emer Heat Changeover Valve Compressor C C 4 Y1 W2 W1 RH Y1 O/B W1 RH 2 3 Conventional Heat Pump Power Bridge Transformer Heat Pump Thermostat Notes: • C-wire optional • The W1 terminal is used for Auxiliary/Emergency heat or on Dual Fuel systems 16 | (215) 788-8485
Technical Information: Disconnection Means: Type 1B Pollution Degree: 2 Impulse Voltage: 330V Automatic Action: 100,000 cycles Electrical Rating: -Input: 24V a.c. 60Hz or 4xAA Alkaline battery -Output: @24V a.c. Max. 1.5A FCC Part 15C 4. APPENDIX Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
H2O Degree Bensalem, PA 19020 H2ODegree.