Installation Guide

www.milleredge.com info@milleredge.com 800-220-3343
IMPORTANT: READ AND UNDERSTAND ALL
INSTRUCTIONS BEFORE BEGINNING INSTALLATION
The Miller Edge RBand Monitored Door Edge Transmitter/Receiver system is intended to provide a wireless
connection between a monitored sensing edge and a motorized operator installed with a garage door or grille.
RBand meets the 2016 UL 325 requirements for monitored devices and has been certified as a UL 325 Recognized
Component. It is designed for use with operators that comply with 2016 UL 325 using a Miller Edge 10K Sensing
Edge.
1. PARTS LIST
Kit Contents:
1. RBand Edge Transmitter (RB-TX10)
2. RBand Door Edge Receiver (RB-D-RX10)
3. (2) 3.6V AA lithium batteries*
4. (4) #6 pan head transmitter mounting screws
*Replacement 3.6V AA lithium batteries can be
purchased at your local electronics store or via
Miller Edge.
Required:
1/8” flat blade screwdriver
1/4” flat blade screwdriver
Miller Edge 10K (T2/blue band) Sensing Edge
Recommended:
Multi-meter capable of reading 10KΩ
Mounting screws as required for Receiver
2. RECEIVER INSTALLATION
2-1. Turn off power to the door operator.
2-2. Remove Receiver cover and mount the Receiver base
near the operator, where it will be in line of sight with the
Transmitter for the entire range of travel [IMAGE 1].
2-3. Connect power (12-24 VAC/DC) to the terminals marked
power, noting the +/- polarity. 24 VAC power can be
connected either way not polarity sensitive [IMAGE 2].
2-4. Connect wiring from the C1 and BS1 terminals on the
Receiver to the 10K monitored input terminals on the
operator (not polarity sensitive).
2-5. Replace the Receiver cover and turn on power to the
operator. Note: it takes ~5 seconds for the Receiver to
initialize.
Note: RBand 10K Door Edge Receiver is compatible with
up to 3 RBand Transmitters.