Facial recognition and temperature measur ement kiosk Use & installation instructions Model: KMT-0080U-2CAWU
1. Product installation This product is upright, with the use of multiple types of base, other products (including embedded and wall-mounted) will be introduced later.
Pillar installation method Step 1. Twist out the ring at the bottom of the monitor and remove the base cover (step 1) Step 2.
Step 3. There are preset interfaces on the base to connect them to the monitor. ( Different models will have different interfaces, one-to-one connections, depending on the actual situation. )DC 12V & USB (Step 3) Step 4. Put the cable into the base and fix the cover on the base together with the monitor. (Step 4) Step 5. Connect the power supply to the base and start working.
Desktop installation method Step 1 . Open the cover of the desktop base bottom. Step 2. Insert the monitor into the desktop base and secure with a ring Step 3. There are preset interfaces on the base to connect them to the monitor. ( Different models will have different interfaces, one-to-one connections, depending on the actual situation. )DC 12V & USB Step 4. Restore the bottom cover, connect the power supply to the base and start working.
2. MIPS & Android This product is based on android system, installed with MIPS face recognition temperature measurement application, with built-in face recognition camera module and infrared temperature detector, capable of personnel access management and temperature detection.The user stand in front of the camera to check the body temperature. There is no need for human contact.It is recommended that the distance from the camera is 0.
2.2 MIPS file storage path Real-time data MIPS will automatically record all visitors, generate a picture file, and store it locally in the android system explorer. The specific path is: Internal Memory / currentlmg Entry data MIPS can also take the initiative to input personnel data, as a comparison basis for face recognition. In the MIPS application menu, select Face data entry operation. The corresponding generated image data is store it locally in the android system explorer.
3. MIPS function description Connect the mouse, Click on the middle mouse button, enter the default password "123456" to open the [Application Management] interface, which displays the current login state, and five functions, i.e. “Application settings”, “Face data entry”, “Application information”,”Pass record” and “Face database”; (Click the mouse button, enter the operation password) (Open the application management interface) 3.
Device name setting : Custom device name Body temperature setting (Temperature detection setting interface) 3.1.2.1 Temperature detection: open, means to open the temperature detection function; Turn off means turn off the temperature detection function; 3.1.2.2 Compensation temperature: compensation value is set according to the ambient temperature. When the ambient temperature is higher than 25°C, it is set as -0.3; when the ambient temperature is lower than 25°C, it is set as +0.3; 3.1.2.
Identification parameter settings (Identification parameter settings interface) For the judgment coefficient of face recognition AI, please use the default value of the system, and it is not recommended to adjust 3.1.3.1 Check threshold : set the face detection parameters, default is 17, normal without changing; 3.1.3.2 Recognition times : set the number of face recognition confirmation, default is 3 times, normal without changing; 3.1.3.
Startup settings (Startup settings interface) set the startup items of the application, start up automatically by default, normal without changing; 3.1.5.1 Auto start : Automatically start the application after powering up 3.1.5.2 Application daemon : confirm whether the application is in priority working state within the cycle. If not, the application will be opened automatically. 3.1.5.3 Application thread daemon : the application will take priority in system memory.
Recognition effect display (Recognition effect display interface) Set the feedback effect after face recognition and temperature measurement, Including image display and lighting. Password setting Sets the operation password, which is used to call out the menu or exit the application. Default: 123456; Camera resolution preview settings Set the camera preview image resolution, optional: 640*480 or 1280*720. Lock Screen brightness setting Set the screen brightness in lock mode.
Relay setting (Relay setting interface) Optional modes and Settings after connecting external relays. 3.1.12.1 Mode 0 : Unautomatically close mode, the relay will not automatically close after opening. 3.1.12.2 Mode 1 : High efficiency auto close mode, the relay will automatically close after opening. 3.1.12.3 Mode 2 : Low efficiency auto close mode, the relay will automatically close after opening. 3.1.12.4 Delay : Set the response time of auto close shutdown, that is delayed close.
3.2 Face data entry Take the initiative to input personnel face data, as a comparison basis for face recognition. The corresponding generated image data is store it locally in the android system explorer. The specific path is: Internal Memory / viplmg 3.3 Face database This options is used to manage face database information, and can be used to add and delete face data.
3.4 Pass record MIPS will automatically record all visitors, generate a picture file, and store it locally in the android system explorer. The specific path is: Internal Memory / currentlmg This data can be exported to external storage via USB. 3.
FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.