UHF Reader LogiRead-UX1 USER MANUAL Tel: 972-9-835-4848 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504 Israel Page Fax: 972-9-865-6262 1/12 LogiTag Systems LTD. www.logi-tag.
Product name p/n Document p/n date UHF Reader LogiRead-UX1 user manual LogiRead-UX1 Product rev. B02 LT-D-0111 Document rev. Author name 01 28/03/2012 Documents changes and version Date Name Change description 23/04/2012 Golan K Document release Golan K. version 01 Tel: 972-9-835-4848 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504 Israel Page Fax: 972-9-865-6262 2/12 LogiTag Systems LTD. www.logi-tag.
1. Safety Instructions / Warning - Read before start-up ! • The device may only be used for the purpose intended by the manufacturer. • The operation manual should be kept readily available at all times for each user. • Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude the manufacturer from any liability.
• Do not drop, throw or try to bend the device. • Do not immerse in liquid or expose to excess humidity. Tel: 972-9-835-4848 2 Hamelacha St., Poleg Industrial Zone, Natanya ,P.O.B 8249, ZIP 42504 Israel Page Fax: 972-9-865-6262 4/12 LogiTag Systems LTD. www.logi-tag.
2. System description and operation The LogiRead-UX1 is UHF RFID Reader, a system for read and write operations for UHF RFID transponders. It can be operated by host computer with Bluetooth link support. The device is powered of rechargeable LI-PO battery, can be charge either by 5V 3A adaptor or USB connection to host. Device has power button and Leds indication. The device can operate at frequency range of between 860-928MHz, according to local authorizations and federal communications laws.
The system has 2 interface connectors: • • DC power jack for battery charging Mini USB 5 pin connector for battery charging 2.1 LED Display And Button Button: to power on/off the device. Led indicators: • • • • PWR – LED is on when device is connected to adaptor or USB. BAT – LED is on when device is powered of internal battery. BT – LED is on when Bluetooth connection established. RFID – LED is on whenever the device identifies a transponder. Tel: 972-9-835-4848 2 Hamelacha St.
Led status table: Led type and color PWR - red Led mode on blinking blinking fast off BAT - green off BT - blue RFID - yellow on blinking on on Device status either USB cable or adaptor connect to the device and battery fooly charged either USB cable or adaptor connect to the device and battery is charging during system power up by pressing the button device powered of internal battery either USB cable or adaptor connect to the device device powered of internal battery, PWR led is off battery need to b
2.5 RFID transponders The system supports UHF GEN2 and ISO 18000-6C RFID transponders. Transponders reading range up to 3m. 2.6 System operation: To operate the system: 1. Press the power button; make sure either BAT or PWR led are on. 2. Make sure the BAT led is not blinking. If it blinks – battery is at low capacity, connect to adaptor or USB cable for charging. 3. Establish BT connection either from PC or PALM computer.
• Click OK • Make sure you disconnect the Bluetooth connection to the reader before starting an application which tries to connect with it again. • It is recommended to perform a full reset to the pocket PC after initial definition of the reader Bluetooth port For PC: • Open the BT wizard and search for devices. • Select the reader according to its BT ID number. • Choose "use the device ID" and insert password 1234 • Check which COM ports numbers the BT device received.
3. Radio approvals: 3.1 USA (FCC): Product p/n: LogiRead-UX1-NA The device includes the following modules: • Module FCC ID QV5MERCURY5E • Module FCC ID PI403B Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
3.2 EUROPE: Product p/n: LogiRead-UX1-EU Product EMC approvals: • Device certifications: EN301489-1, EN301489-3, EN301489-17 Modules approvals: • BT module: EN 300 328 V1.6.1 (2004 – 11); EN 301 489-1 V1.4.1 (2002 – 08). • RFID module: EN 302 208-1 V1.1.2; EN 302 208-2 V1.1.1 3.3 CANADA: Product p/n: LogiRead-UX1-NA The device includes the following modules: • Contains transmitter module IC: 5407A-MERCURY5E • Contains transmitter module IC: 1931B-EUSB Tel: 972-9-835-4848 2 Hamelacha St.
4. System Technical data: • Mechanical data: o Dimensions (W/L/H ) 136*85*23.2mm o Weight 260gr. • Electrical data: o Supply voltage 5V +/-5%, 3A, LPS o RFID transmitting power 1W max. • Interface: o BT o USB • Supporting transponders: o UHF EPC GEN2 o ISO 18000-6C • Temperature range: o Battery charging: 0°C to +45°C o Operation: -20°C to +60°C o Storage: -20°C to +60°C o Humidity: 5%-65% • Applicable standards: o Radio – FCC CFR 47 part 15 subpart C, 15.247 and 15.231; RSS 210.