Programmable Control Panel Preface Read this user manual carefully before using the product. Pictures are shown in this manual for reference only. Different models and specifications are subject to real product. This manual is only for operation instruction, please contact the local distributor for maintenance assistance. The functions described in this version were updated till April, 2018.
Programmable Control Panel SAFETY PRECAUTIONS To ensure the best from the product, please read all instructions carefully before using the device. Save this manual for further reference. ⚫ Unpack the equipment carefully and save the original box and packing material for possible future shipment. ⚫ Follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons. ⚫ Do not dismantle the housing or modify the module. It may result in electrical shock or burn.
Programmable Control Panel Table of Contents 1. Product Introduction ....................................................................................................1 1.1 Features ............................................................................................................1 1.2 Package List ......................................................................................................1 1.3 Installation ...............................................................................
Programmable Control Panel 1. Product Introduction The programmable control panel JTD-P8 is a Wall Control Panel. Every button is programmable and works either individually or together. The programmable control panel is built in the programmable 3 RS232, 1 RS485, 3 Infrared & 2 Relay, and 1 mini USB for programming. Please notice, RS232 (1) and IR2 share the same port, cannot be used at the same time. Also, RS232 (2) and IR3 share the same port, cannot be used at the same time.
Programmable Control Panel 1.3 Installation Follow the steps to install the device: Firstly, dig a hole on the desk to the size marked on the aperture paper (shown in Figure 1-1). Secondly, put the device into the hole and adjust it to flush with the table (shown in Figure 1-2). Then, plug a set screw into the fixing mounting and screw the nuts tightly.
Programmable Control Panel 2. Panel Descriptions 2.1 Front Panel Crystal and luminescent, programmable buttons: Every button can be programmable with the software JTD-Control. Connect the PC via USB or RS232. And every label inside the button can be changeable.
Programmable Control Panel 2.2 Side Panel Mini USB Connector: 1. Communicate with PC which uses JTD-Control to program the buttons. 2. Transmit the infrared data when learning IR (Optional). Infrared sensor port: receive and learn the IR code, to build the IR database. Note: When use this USB port to program the control panel’s buttons, the available COM port number should not be more than 10. 2.
Programmable Control Panel output. RS232 (2) and IR3 share the same port, the detailed use depends on the setting of JTD-Control. Other part is RS232 (3), it can be used for control other devices or looping output, or connect with PC. These two parts share the same grounding. ② This port includes: RS232 (1)/IR2, IR1 and RS485. a) RS232 (1)/IR2: share the same port, the detailed use depends on the setting of JTD-Control.
Programmable Control Panel 3. Connection Introduction 3.1 System Diagram The programmable control panel can active different ports at one time. It means every button can send the RS232 and RS485 commands, IR code and control the relay at the same time.
Programmable Control Panel 3.2 Connection of Programming and Looping The programmable control panel can be connected to the computer for programming, to default the functions of every button. It can be connected by USB or RS232, working with the JTD-Control software. It is shown as below: Programming Connection Several pieces programmable control panels can be also looped to be a system, for control more devices. It is looped by the inter RS232 setting.
Programmable Control Panel After connect the programmable control panels as above, and then we should set the ID of each programmable control panel by JTD-Control. The ID number is from 01 to 99, and it also is the class of the programmable control panel in the loop, different programmable control panels should set to different ID. After connections finish, we can set the control modes by JTD-Control.
Programmable Control Panel 4. System Operations 4.1 USB Driver Installation There are USB driver file and JTD-Control software in the disk. The JTD-Control can run directly without installation. But when connect the programmable control panel with PC by USB, it may need to install the USB driver. Use the driver file to install the driver of USB, we can use USB to program the programmable control panel. 4.
Programmable Control Panel 4.2.1 Main Menu The main menu includes file management, system model, connection type and help. 1) File management: Open/Save/Save as a configuration. After program, user can save the configuration to a file, so that you can use the same configuration next time. 2) System model: includes programmable control panels-H, programmable control panels-V, WP19R etc., and the buttons interface view are different with different models.
Programmable Control Panel The output port set in JTD-Control and the port used in the programmable control panel is corresponding. And there are four output types.
Programmable Control Panel 4) Help: Show the information of JTD-Control. 4.2.2 Panel/Key setting There are three different colors of keys in the panel set of JTD-Control. Add a key action to action list, then add events to this action, make this action will execute the events.
Programmable Control Panel 1) White keys: keys 1-8, correspond to the buttons on the programmable control panel. Click the key, it will pop up dialog as below: Key Action Type: 1. Press: Execute events when press button. 2. Release: Execute events when release button. 3. Page: Built-in most 4 actions, actions need to be switched by other buttons, press to execute. 4. Toggle: Built-in most 4 actions, actions will loop run when press. Actions can also be switched by other buttons, press to execute.
Programmable Control Panel 2) Blue Keys: Keys 9-32, all are virtual keys, used in the loop function. When use the loop function, the ID must be set, the ID can be 1 to 99. Press “add” will add the button to action list. 3) Yellow Keys: Keys 33-36, all are virtual keys. Key 33 and 34 are for I/O control, which is not supported with the programmable control panel. Key 36 is a start action, if add events to this action, when the programmable control panel is power on, it will execute the events in this action.
Programmable Control Panel 4.2.3 Action list Action list shows all the set actions. An available action must be added to the list. The action list is as the picture below: Delete all actions. Delete a selected action. Refresh, delete all the actions that with no event. 4.2.4 Event setting Event setting includes RS232, IR, I/O, Relay, Delay, Compare, LED, Page, Loop and Toggle setting. Before set events, an action must be added first.
Programmable Control Panel 1) The data of RS232 can be directly entered or selected from library. Click “Change Lib” to select a library file and open it. Click “Edit Lib” to create or edit a library file as below: Create/open a library Create/delete the function name of the command Enter the serial command for device control. Note: When editing finish, remember to save the editing, and then press “OK”. 2) There are two send types: send once and send more times.
Programmable Control Panel ➢ IR Setting This item is used for setting the parameters of the programmable control panel’s IR ports. Click “IR”, it will show as below: 1) The data of IR need to be selected from library. Click “Change Lib” to select a library file and open it.
Programmable Control Panel 2) There are two send types: send once and send more times. When select “more times”, the send times and the delay between times can be set. See in picture below: 3) The send port must be selected as the same as model setting, otherwise the event cannot be added. The IR can set the carrier on/off, to turn on/turn off the IR sending. 4) ➢ I/O Setting There is no I/O port in the programmable control panel, so the setting is not introduced in this manual.
Programmable Control Panel Send Type Port Action: “On” for connected, “Off” for disconnected. ➢ Delay setting This item is to set a delay time, user can add a delay between two events; so when one event is finished, it will delay a certain time then start another event. The delay setting is as picture below: ➢ Compare Setting This item is used for compare the feedback of RS232 commands.
Programmable Control Panel Enter the compare commands, don’t miss any character. 1) 2) 3) The send port must be selected as the same as model setting, otherwise the event cannot be added. And port 1 cannot be used for compare, for there is no a receive pin in this port. User can set the event name; it is optional function, not necessary. For the events in one event list have priority, from top to bottom, so that the compare function can be used in action which with three or more events.
Programmable Control Panel ➢ LED setting This item is used for set the button LEDs in the programmable control panel to turn on/off. The setting is as below: ➢ Page setting White buttons can be set to type “page” that include four actions. To change different actions, it will need other white buttons to active the page action number. Here take a example to show you the use of this function: 1) Take button1 for example: click key1 and select the action type “page”, add the four actions to the action list.
Programmable Control Panel 2) In event setting, we add four different events to the four page actions of key1, and the four other keys will be added the page event to each of them as below: Then set the “page” event to make four “press” actions to active the four page number: key5-num1, key6-num2, key7-num3 and key8-num4.
Programmable Control Panel ➢ Loop Setting This item is used for looping the programmable control panel. When use the loop function, the ID of each programmable control panel must be set. ➢ Toggle Setting The toggle setting is as the picture below: The setting steps of toggle are similar with the page setting.
Programmable Control Panel num3->num4->num1 and so on. b) When press the button6 and then button1, the button1 will execute the event of num2, press button1 more times it will execute num3, then num4->num1->num2 and so on. c) When press the button7 and then button1, the button1 will execute the event of num3, press button1 more times it will execute num4, then num1->num2->num3 and so on.
Programmable Control Panel 5.
Programmable Control Panel 6.
Programmable Control Panel 7. Troubleshooting & Maintenance ⚫ When the control panel cannot work, please check and make sure the power cord connection is well, plug cannot be mixed or connect wrong. Then restart, if still not work, the control panel may be broken. Please send it to the dealer for repairing. ⚫ When USB cannot open or without response, please make sure the USB driver is installed correctly, and then reconnect the USB cable.
Programmable Control Panel 8. Customer Service The return of a product to our Customer Service implies the full agreement of the terms and conditions hereinafter. There terms and conditions may be changed without prior notice. 1) Warranty The limited warranty period of the product is fixed one years. 2) Scope These terms and conditions of Customer Service apply to the customer service provided for the products or any other items sold by authorized distributor only.