Note: Interval data configuration is dependent on the module's firmware version. See
Firmware Functionality on page 11 for more information.
The Cellular 500W also sends a local access beacon message every 60 seconds that allows
users to gather contingency readings locally when needed.
Caution: If you perform a switch to Network Mode or switch to Mobile Mode
operation, it results in a loss of interval data.
The Cellular 500W operates using FCC or ISED licensed spectrum defined by 3GPP ranging
from Band 4 (744-787 MHz) and Band 13 (1710-2155) operation 612054.
Operating Modes
The Cellular 500W has the following operating modes.
■
Factory Mode
–
Remote modules are shipped from the factory in Factory Mode.
–
The module's transmitter is turned off.
–
The module's receiver is bubbling-up to listen for a programming command.
–
Remote modules will attempt to read the register every hour.
–
Register Error Detected and Register Error alarm or event flags may be set when a
register is not connected.
–
If the Cellular 500W reads a connected register, the module automatically moves to
Run Mode.
■
Audit Mode
–
Audit Mode reduces the normal read latency time associated with standard modes of
operation and is often used after initial installation.
–
This mode is useful in network installations where the normal bubble rate is very slow.
–
Audit Mode remains active for 30 days and then reverts to the initial programmed
mode.
–
Audit Mode is intended to be used once.
■
Run Mode
–
Remote module normal operation mode.
–
The remote module's transmitted message is dependent on its factory settings for
standard consumption + messages (SCM+).
–
SCM+ remote module default bubble-up rate is 10 seconds.
Cellular 500W Remote Module Installation Guide 1 Introduction
October 11, 2021 815-0618-00 REV 000 Itron, Inc. Page 9 of 44