Completing Gel-cap Connections Using the
Itron Splice Tube Kit
Important! All unused wires on modules must be terminated. Wire terminations
must be properly sealed with a non-conductive gel material to prevent water
intrusion and possible environmental or electrical issues.
Required Materials
■
E-9R 3M
®
gel connector crimping tool (or other 3M approved crimping tool)
■
Itron splice kit (part number OEM-0034-002)
To complete gel-cap connections
1. Push two wires as far as possible into the connector.
Caution: Do not strip insulation from the ends of the wires before inserting them
into the connector.
2. Carefullyplace the connector and wires into the jaws of the crimping tool. Make sure the
wires remain fully inserted in the gel-cap connector.