mount kit.
Important! While Itron modules are designed to withstand a drop, dropping the
module can damage sensitive electronic components and void the product
warranty.
Mounting Accessories
Accessory Part number
Remote mount kit (Cellular 500W with telemetry device) CFG-1300-003
Pipe mount kits
Pipe mount kit for pipe diameters up to 4” CFG-0217-501
Pipe mount kit for pipe diameters between 3/4” to 1-3/4” CFG-0217-503
Pipe mount kit for pipe diameters between 1-5/16” to 2 ¼” CFG-0217-504
Cable armor (for field retrofit installation instructions, Itron Cable Armor Installation on page 34)
5 foot cable thin-insulation (with protective cover and cable armor) CFG-0151-006SS
5 foot cable thick-insulation (with protective cover and cable armor) CFG-0151-010SS
5 foot cable armor for field retrofit FAB-1302-001
Direct mount screw pack SCR-0010-005
Direct mount screw pack, bulk: 80 per bag SCR-0010-004
Direct mount screw pack, bulk: 122 per bag SCR-0010-001
Direct-mount to the Meter Register
Direct-mounting Cellular 500Ws to a meter register requires a register designed for that
purpose. This section describes Cellular 500W installation for the following direct mount
registers:
Badger ADE and RTR
Elster/AMCO (ABB) Scancoder, InVISION, and Digital
Warning! Do not use the direct mounting method in a pit environment. Use a
Cellular 500W for pit environments. Remote modules direct mounted in a pit
environment are not covered by the Itron warranty.