Pulser-type Register Connections
Connect the Cellular 500W cable to the register according to the following table.
Remote module wire color
Brown Gray Yellow
Register manufacturer Register screw color designator
■ Badger RTR (3-wire)
Red Black Green
■ Badger RTR (2-wire)
Red Black No connection*
■ Badger M5000 Mag Meter
Red terminal: Out 1+ Black terminal: Out 1- White terminal: Out 1+
■ Cadillac Meter CMAG/EMAG
■ Magnetic Flow
DO1/DO2 COM COM
■ Elster Digital
Black Green Red
■ Elster V100T
Red &Black Blue Yellow
■ Itron (Actaris)
■ Flostar (2-wire)
■ Cyble Sensor
Either wire Remaining wire must be connected to both
module wires
■ Krohne IFC
Term B Term H Term B
■ RG3 Tomahawk
Green Black Green
■ Sensus PMM
Red Black Bare
Note: *Itron recommends terminating unconnected wires with a gel-cap connector to
protect the bare wire end. See Completing Gel-cap Connections Using the Itron Splice
Tube Kit on page 38 for more information.
Cable Extension
Order the 25 foot inline connector extension cable assembly (CFG-0151-404) to extend the
Cellular 500W cable.
Operation Verification
Use one of the following programming devices to verify that the Cellular 500W is correctly
recording consumption data.
Cellular 500W Remote Module Installation Guide 2 Initialization, Connection, andProgramming
October 11, 2021 815-0618-00 REV 000 Itron, Inc. Page 16 of 44