Water Solutions 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide TDC-0909-006
Identification 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 22 January 2013 TDC-0909-006 100W/100W+ and 100WP/100WP+ ERT module Copyright © 2010 - 2013 Itron, Inc. All rights reserved. Confidentiality Notice The information contained herein is proprietary and confidential and provided subject to the condition that (i) it is held in confidence except to the extent required otherwise by law and (ii) it is used only for the purposes described herein.
Transportation Classification The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, ERT modules are considered operating transmitters and receivers and cannot be shipped by air. All product returns must be shipped by ground transportation to Itron. Suggestions If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.
TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential iv
Contents Chapter 1 Before You Begin ........................................................................................ 1 Document Conventions ....................................................................................................................... 1 Document Purpose .............................................................................................................................. 1 How This Document is Organized .................................................................
Contents Chapter 5 Optional Direct Connect Remote Antenna Installation .......................... 34 100W/100W+ and 100WP/100WP+ ERT Module Models for use with Remote Antennas ..............34 Industry Canada Conformity .............................................................................................................35 Installing the Remote Antenna ..........................................................................................................35 Appendix A Using an Inline Connector ..
CHAPTER 1 Before You Begin Document Conventions Convention Itron product part numbers are noted in parentheses. Example To install the ERT module (ERW-1300-XXX), do the following steps. Hypertext links are in blue. See How The Document is Organized on page 1 for document structure information. Note A Note indicates neutral or positive information that stresses or supplements important points of the main text. A note supplies information that may apply only in special cases.
Before You Begin Chapter Description 4. Installing the 100W/100W+ and 100WP/100WP+ ERT Module Step-by-step ERT module installation instructions for: • Rod mount • Wall mount • Base mount • Shelf mount (kit CFG-1300-001) • Through lid mount • Optional Leak Sensor installation 5. Optional Direct Connect Remote Antenna Installation Instructions for installing the optional remote antenna. Appendix A Using an Inline Connector Instructions for installing an inline connector.
CHAPTER 2 About the 100W/100W+ and 100WP/100WP+ ERT Module The 100W/100W+ and 100WP/100WP+ ERT modules are high-power radio frequency automatic meter reading (AMR) devices that attach to water registers to collect consumption usage and tamper data the ERT module then transmits to a data collection device. The ERT module operates in both bubble-up mode and twoway mode. The 100W/100W+ and 100WP/100WP+ ERT modules ship in factory mode.
About the 100W/100W+ and 100WP/100WP+ ERT Module Communication Error Indicators. • Last Good Read (LGR Flag) Indicates a communication error with the register. • 100W/100W+ encoder ERT module If this flag is set for 24 consecutive hours, it initiates a cut cable flag in the extended tampers. The LGR Flag automatically clears after the ERT module receives a successful read from the register.
About the 100W/100W+ and 100WP/100WP+ ERT Module 100W/100W+ and 100WP/100WP+ ERT Module Description Itron Part Number 100W+ encoder, 20-in. cable register connect, direct connect remote antenna integral connector, ISM ERW-1300-317 100W encoder, 20-in. cable register connect, direct connect remote antenna, and Leak Sensor or integral connectors ERW-1300-218 100W+ encoder, 20-in.
About the 100W/100W+ and 100WP/100WP+ ERT Module Itron Security Manager (ISM) Users have the option of enabling the ISM enhanced security in the 100W+ and 100WP+ ERT module. ISM is a component of a ChoiceConnect system. ChoiceConnect system security applies to the RF communications between the handheld computer, Mobile Collector, or Fixed Network system and the ERT module.
About the 100W/100W+ and 100WP/100WP+ ERT Module 100W/100W+ and 100WP/100WP+ ERT Module Transmission Modes The 100W/100W+ and 100WP/100WP+ ERT module can be set to transmit in fixed network, mobile high power, mobile and handheld, or hard to read mobile and handheld mode. • • • • Fixed Network Mode. The 100W/100W+ and 100WP/100WP+ ERT module transmits a high-powered NIM RF message every six minutes and a contingency SCM+ RF message every minute. Mobile and Handheld Mode.
About the 100W/100W+ and 100WP/100WP+ ERT Module 2. Run Mode • 100W/100W+'s normal operation mode. • The 100W transmitted message is dependent on its factory settings for standard consumption messages (SCM), standard consumption + messages (SCM+), or network interval message (NIM). o For SCM and SCM+, the 100W/100W+ default bubble-up rate is 9 seconds. o For NIM, the 100W/100W+ default bubble-up rate is 5 minutes.
About the 100W/100W+ and 100WP/100WP+ ERT Module 2. Run mode • 100WP/100WP+s normal operation mode. • The 100WP/100WP+ transmitted message is dependent on its factory settings or FDM programming for standard consumption messages (SCM, SCM+) or network interval message (NIM). • For SCM/SCM+ (mobile), the 100WP/100WP+ default bubble-up rate is 9 seconds. • For NIM (fixed network), the 100WP/100WP+ default bubble-up rate is five minutes.
CHAPTER 3 Initializing, Connecting, and Programming the ERT Module This chapter provides the instructions to initialize and start up the 100W/100W+, program and start up the 100WP/100WP+, and connect the 100W/100W+ or 100WP/100WP+ ERT module. Initializing the 100W/100W+ ERT Module Caution To obtain an immediate reading, initialize the 100W/100W+ with an approved handheld computer. Failure to initialize the ERT module may delay the initial reading up to one hour.
Initializing, Connecting, and Programming the ERT Module Programming the 100WP/100WP+ ERT Module Programming the 100WP/100WP+ requires one of the following handheld computers running Field Deployment Manager (FDM) version 3.2 or later. • • FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004) FC300 with SRead For normal activation, connect the 100WP/100WP+ to the water meter register and program the ERT module with FDM.
Initializing, Connecting, and Programming the ERT Module To connect the 100W/100W+ to the register Connect the 100W/100W+ wires to the register screw terminals according to the following table.
Initializing, Connecting, and Programming the ERT Module Connecting the 100WP/100WP+ ERT Module to a Remote Meter Register Connect the wires from the ERT module to the register according to the following table.
CHAPTER 4 Installing the 100W/100W+ and 100WP/100WP+ ERT Module Install the 100W/100W+ and 100WP/100WP+ ERT module using one of the following methods: 100W/100W+ and 100WP/100WP+ Mounting Options Rod mount The ERT module mounts on a 1/2-inch outside diameter rod. Wall mount The ERT module mounts to a wall or other vertical surface. Base mount The ERT module mounts on a horizontal, flat surface.
Installing the 100W/100W+ and 100WP/100WP+ ERT Module 100W/100W+ and 100WP/100WP+ ERT Module with Integral Connectors If 100W/100W+ and 100WP/100WP+ ERT modules with integral connectors (ERW-1300-X0X) and the registers are not installed at the same time, secure the protective environmental connector cover on the ERT module using an Itron Security Seal (Itron part number MSC-0018-001). Cable ties are not shipped with the 100W/100W+ and 100WP/100WP+ ERT module, but can be ordered from Itron.
Installing the 100W/100W+ and 100WP/100WP+ ERT Module Required Tools and Hardware • • • • • Hammer 1/2-inch outside diameter rod (you may use either a square or round rod) Tape measure Rod-driving tool (optional) Rod cutting tool The 1/2-inch diameter rod hole is shown in the following 100W/100W+ and 100WP/100WP+ ERT module bottom and side views. To install the 100W/100W+ and 100WP/100WP+ ERT module on a rod 1. Remove the pit lid.
Installing the 100W/100W+ and 100WP/100WP+ ERT Module 5. Drive the rod into the ground so the top of the rod is approximately 3-1/2 inches below the bottom of the pit lid. • If you cannot drive the rod in enough to equal the necessary spacing, cut the remaining rod length to the proper height using an abrasive cut-off tool. Caution Cutting fiberglass creates dust particles. Practice proper safety precautions when using cut-off tools to prevent exposure to fiberglass dust particles.
Installing the 100W/100W+ and 100WP/100WP+ ERT Module 7. Installation is complete when the ERT module is perpendicular to the underside of the lid. The ERT module must not contact the pit structure or lid. Caution Verify the pit lid does not touch the ERT module when the lid is replaced. There must be a 1 to 2-inch space between the top of the ERT module and the bottom of the pit lid. If the ERT module is installed too high, too low, or is touching any of the surrounding surfaces, adjust as necessary.
Installing the 100W/100W+ and 100WP/100WP+ ERT Module To install the 100W/100W+ and 100WP/100WP+ ERT module using the wall mount procedure 1. Select a vertical surface in the pit box or on a wall (for example, an ERT module mounted in a basement). 2. Position the ERT module vertically so the top of the ERT module is between 1 and 2-inches below the bottom of the lid. 3. Mark the location of the top mounting hole. 4. Drill a pilot hole in the pit box wall.
Installing the 100W/100W+ and 100WP/100WP+ ERT Module 100W/100W+ and 100WP/100WP+ ERT Module Installation in a New Lid This section describes installation of the 100W/100W+ and 100WP/100WP+ ERT module in a pit lid without a drilled hole. To install the 100W/100W+ and 100WP/100WP+ ERT Module in new lids 1. Select a hole location with enough clearance on the bottom side of the lid to attach the threaded clip collar. 2. Drill a 1-3/4 inch hole in the lid. 3.
Installing the 100W/100W+ and 100WP/100WP+ ERT Module Caution Do not over-tighten the mounting screws. Over-tightening the mounting screws may break the ERT module mounting tabs. Shelf Mount Installation This section describes 100W/100W+ and 100WP/100WP+ ERT module installation using a shelf mount adapter to mount the ERT module in a pit lid slot.
Installing the 100W/100W+ and 100WP/100WP+ ERT Module The following illustration and the accompanying table give pit lid slot dimensions for the shelf mount installation method. Pit Lid Slot Dimensions Dimension Minimum (inches) Maximum (inches) A 6 3/4 N/A B 2 5 3/4 C 3/4 1 Required Hardware Itron 100W Series Shelf Mount Kit To install using the shelf mount adapter 1. With the foam spacers facing up, insert the shelf mount adapter into the opening in the disk. 2.
Installing the 100W/100W+ and 100WP/100WP+ ERT Module 3. Slide the adapter assembly into the pit lid with the foam spacers positioned on each side of the pit lid slot. Correct position for foam spacers Caution Do not install the adapter assembly in a manner that provides little or no support under disk's edge. Incorrect mounting position for foam spacers. 4. The installed ERT module position must be vertical and upright when the lid is replaced on the pit.