Installing the 100W Endpoint Base Mount Installation The 100W may be mounted to a flat surface using the base tab. Caution Observe the following guidelines for mounting the 100W using the wall mount procedure: Endpoint positioning other than upright could negatively affect radio performance and battery life. Use only Itron-approved splice kits or inline connectors. Required Base Mounting Tools and Hardware Drill and drill bits appropriate for mounting location material.
Installing the 100W Endpoint Shelf Mount Installation This section describes 100W endpoint installation using a shelf mount adapter to mount the endpoint in a pit lid slot. Caution Observe the following guidelines for mounting the 100W using the wall mount procedure: Endpoint positioning other than upright could negatively affect radio performance and battery life. Use only Itron-approved splice kits or inline connectors.
Installing the 100W Endpoint To install using the shelf mount adapter 1. With the foam spacers facing up, insert the shelf mount adapter into the opening in the disk. 2. Push the adapter into the opening gently until the adapter snaps into place. Insert the shelf mount adapter into the 100W endpoint antenna slot pushing firmly with your thumb until the adapter tab locks into place in the 100W antenna slot opening.
Installing the 100W Endpoint 3. Slide the adapter assembly into the pit lid with the foam spacers positioned on each side of the pit lid slot. Correct position for foam spacers Caution Do not install the adapter assembly in a manner that provides little or no support under disk's edge. Incorrect mounting position for foam spacers. 4. The installed endpoint position must be vertical and upright when the lid is replaced on the pit.
Installing the 100W Endpoint Required Tools and Hardware This mounting method requires the Pit Lid Mounting Kit. Refer to the 100W Installation Methods Overview (PUB-1300-004) for guidance on which kit to install for different pit lid material and traffic conditions. Pit Lid Mounting Kit (CFG-1300-004) Note The Pit Lid Mounting Kit is not intended for applications involving vehicular traffic. Use the Remote Antenna Kit in incidental traffic areas (such as residential environments).
Installing the 100W Endpoint 2. Insert the retainer clip into the pit lid hole with the convex surface on the top of the pit lid. 3. From the bottom side of the lid, screw on the threaded retainer clip collar until the beveled top rests against the pit lid. Note Ensure the beveled edge of the clip collar is toward the top of the pit lid. 4. Align and insert the retainer clip tab into the retainer clip receptacle on the 100W housing.
Installing the 100W Endpoint 5. Verify the clip locks into place in the housing. Caution Carefully align the 100W through lid assembly. If the assembly is improperly aligned, the pit lid may not close. Pit Lid Mounting Kit installation is complete. Installing the Endpoint in a New Lid This section describes installation of the 100W endpoint in a pit lid without a drilled hole. To install the 100W in new lids 1.
Installing the 100W Endpoint Optional Leak Sensor Installation Leak Sensors (LS) analyze water flow sound patterns to detect new, evolving, and pre-existing leaks. LS analysis data is uploaded to mlogonline™ Network Leak Monitoring for data analysis and accessed through a secure Internet portal unique to your utility. This section describes installation of the Leak Sensor (LS) in a 100W system. The 100W endpoint stores 20 days of Leak Sensor data.
Installing the 100W Endpoint To connect the Leak Sensor to the 100W endpoint Caution Verify you have the correct 100W or 100WP endpoint. Leak Sensors must mount to Port B (top port) of the endpoint. Connecting the LS to Port A (bottom port) will cause electrical damage to the LS and 100W endpoint. 1. Remove the environmental cap from the 100W endpoint blue connector (B). B. 100W blue connector: Leak Sensor connection A. 100W black connector: Register connection 2.
Installing the 100W Endpoint 4. Rotate the connector locking ring until the security holes align. Caution Do not force the connector ends together. While holding the LS connector, engage the 100W connector by rotating the locking ring until both connectors securely connect. Twist only the connector locking ring, not the body of the connector. Twisting the connector body could damage the connector's pins.
Installing the 100W Endpoint 1. Insert the pointed end of the security seal through the inline connector and the 100W connector security holes. 2. Insert the pointed end of the security seal into the capped end and push until the seal locks. This completes 100W endpoint and Leak Sensor connections. Pipe Preparation Clean any dust or dirt from the pipe to facilitate direct contact with the LS surface. To install the Leak Sensor on a pipe or meter insetter 1.
Installing the 100W Endpoint 2. Verify the pipe’s mounting surface is free from dirt and debris. Place the curved surface of the LS against the pipe. 3. Insert the mounting U-bolt over the pipe and into the LS mounting holes. Caution Do not mount the Leak Sensor on a pipe coupler, joint, or nut.
Installing the 100W Endpoint 4. Insert the mounting plate over the U-bolt's threaded screw ends. Attach the two wing nuts over the clamp screw ends and tighten the wing nuts until snug (to a minimum of 5-inch pounds) to prevent device rotation on the pipe. After you tighten the second wing nut, check the Leak Sensor to verify the device is snug. If the sensor moves, tighten the wing nuts until there is no movement. Caution Do not tighten the Leak Sensor to more than 20 inch-pounds.
Installing the 100W Endpoint Caution Mount the Leak Sensor on the water input side of the meter. Failure to follow this mounting requirement could result in errors in the leak detection data. Installation requires Itron mounting hardware. Repair costs and service charges relating to the use on non-compliant mounting hardware will be charged to the customer. Contract Itron Support for more information. 2. Insert the mounting plate screws into the holes on the Leak Sensor's curved surface. 3.
Installing the 100W Endpoint 5. Insert the U-bolt around the pipe and into the holes in the plate/Leak Sensor assembly. Secure the U-bolt with the wing nuts. Tighten the wing nuts until snug (to a minimum of 5-inch pounds) to prevent device rotation on the pipe. After the second wing nut is tightened, check the Leak Sensor to verify the device is snug. If the sensor moves, tighten the wing nuts until there is no movement. Caution Do not tighten the Leak Sensor to more than 20 inch-pounds.
CHAPTER 5 Optional Remote Antenna Installation The optional 900 MHz remote mount antenna provides increased RF range coverage for the listed mobile applications: Meters located deep in a pit boxes. Meters submerged in water for extended periods of time. Meters in Fixed Network systems. This section provides antenna mounting instructions through a pit lid and the instructions to connect the antenna to the 100W. Caution Optional remote antenna installation applies only to mobile applications.
Optional Remote Antenna Installation To mount the optional remote antenna through a pit lid 1. Insert the remote antenna into the pit lid hole with the convex surface on the top of the pit lid. (These instructions show a simulated pit lid material.) 2. From the bottom of the lid, screw on the threaded collar two or three turns. Turn the threaded collar until it is tight against bottom of the pit lid. Verify the antenna dome does not move up and down or shift laterally .
Optional Remote Antenna Installation To connect the remote antenna coupler to the endpoint 1. Insert the remote antenna cable coupler into the endpoint's antenna slot with the flat side of the coupler against the endpoint housing. 2. Push the antenna coupler into the antenna slot until the coupler locks into the tabs of the antenna slot. Important Verify the antenna coupler locks with the antenna slot's tabs. Remote antenna installation is complete.
APPENDIX A Using an Inline Connector This section describes the 100W and 100WP connections to the water meter register using the inline connector assembly. Follow the manufacturer's recommended procedure for installing the water meter register on the meter. To connect the inline connector Note If an inline connector is not used and the 100W endpoint is already connected to the water meter register, skip this step. 1.
Using an Inline Connector 3. Twist the register cable's black coupling nut to align the two tabs. 4. Install the security seal as shown. Push it until it snaps into place. Note For future meter or endpoint servicing, break the security seal by pulling the seal apart. The original protective connector covers can be reused if kept clean and dry. Install a new security seal after servicing either device. To order more parts, see the Water Endpoint Ordering Guide (PUB-0063-001).
APPENDIX B Using Gel-cap Connectors This section describes connecting the 100W endpoint to the water meter register using gel cap connectors. Required Materials E-9R 3M® gel cap crimping tool Itron Splice Kit (OEM-0034-002) 1. Push two wires as far as possible into the connector. Caution Do not strip insulation from the ends of the wires before inserting them into the connector. 2. Carefully place the connector and wires into the jaws of the crimping tool.
Using Gel-cap Connectors 3. Crimp the connector by squeezing the handles until the connector cap is fully seated. Continue to apply pressure for three seconds. 4. A connector is crimped properly when the top of the movable yellow center (1) is flush with the top of the connector body (2). Warning Crimping the connector forces some sealant out of connector. The sealant protects the inside of the connector against insects, moisture, and other contaminants.
Using Gel-cap Connectors 5. After you complete all endpoint to register wire connections, arrange the connectors in a single file. 6. Insert the connectors and wires into the splice tube until the connectors and wires completely immerse in the tube's gel material. 7. Separate the cables to the sides and close the splice tube cover. 8. Discard any leftover materials from the customer premises.
APPENDIX C Troubleshooting TDC-0909-002 100W and 100WP Pit Datalogging Water Endpoint Installation Guide Proprietary and Confidential 40
Index Symbols & Numbers R 100W and 100WP Models • 4 100W and 100WP Transmission Modes • 4 100W endpoint Accessories • 10 100W endpoints with Integral Connectors • 10 100W Operating Modes • 5 100WP Operating Modes • 5 Related Documents • 2 Required Base Mounting Tools and Hardware • 17 Required Equipment • 24 Required Tools and Hardware • 12, 15, 18, 21 Rod Mount Installation • 11 S A Shelf Mount Installation • 18 About the 100W Endpoint • 3 T B Initializing the 100W • 7 Installing and Connecting • 7