Natural Gas Solutions 100T-HON Honeywell Telemetry Module Installation Guide TDC-1346-000
Identification 100T-HON Honeywell Telemetry Module Installation Guide 13 March 2013 TDC-1346-000 100T-HON 100-T HON part number: TEL-1000-002 Copyright © 2013 Itron, Inc. All rights reserved. Confidentiality Notice The information contained herein is proprietary and confidential and is provided subject to the condition that (i) it is held in confidence except to the extent required otherwise by law and (ii) it is used only for the purposes described herein.
Suggestions If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com If you have questions or comments about the software or hardware product, contact Itron Technical Support: Contact • Internet: www.itron.com • E-mail: support@itron.
TDC-1346-000 100T-HON Honeywell Telemetry Module Installation Guide Proprietary and Confidential iv
Contents Before You Begin ......................................................................................................... vi Document Purpose ............................................................................................................................. vi Document Conventions ...................................................................................................................... vi Chapter 1 About the 100T-HON Honeywell Telemetry Module ...............................
Before You Begin Before You Begin Document Purpose This installation guide provides step-by-step instructions for installing the 100T-HON telemetry module on a Honeywell Mercury Instrument. Document Conventions The following documentation conventions are used in this installation guide. Caution A Caution warns the installer that failure to follow the information in the note could result in loss of data. Be sure to carefully read a Caution note and follow the advice or instructions.
CHAPTER 1 About the 100T-HON Honeywell Telemetry Module Itron 100T-HON telemetry modules are radio-frequency (RF) devices designed to transmit meter and instrument data to an RF meter reading device within transmission distance of the module. The 100T-HON is designed to interface specifically with Honeywell Mercury Instrument devices and communicates using a protocol similar to other Itron AMR devices. The 100T-HON provides both a traditional meter reading RF interface and a new telemetry RF interface.
About the 100T-HON Honeywell Telemetry Module Honeywell product features are beyond the scope of this installation guide. Please reference the Honeywell product information for your particular Mercury Instrument. Transmission Modes The 100T-HON telemetry module can be set to transmit in fixed network or mobile and handheld mode. • Fixed Network Mode. The 100T-HON telemetry module transmits a high-powered network interval message (NIM) RF message every five minutes.
About the 100T-HON Honeywell Telemetry Module Itron Security Manager The 100T-HON telemetry module addresses two types of security, ChoiceConnect networking and 100THON to Honeywell device communication, provided by Itron Security Manager. ChoiceConnect Networking The first model is a traditional Itron protocol that includes a complete system knowledge of the content and purpose of each message.
About the 100T-HON Honeywell Telemetry Module Channel-based data logging requests/responses Datalogging request channel Datalogging response channel Telemetry requests/responses 100T-HON telemetry module two-way request 100T-HON telemetry module two-way response • ERX.
About the 100T-HON Honeywell Telemetry Module Like fixed network mode, the 100T-HON telemetry module behavior in mobile mode varies based on the connected Honeywell device. • EVC.
About the 100T-HON Honeywell Telemetry Module Related Documents Document Title Document Part Number 100 Series and CENTRON Tamper Reference Guide TDC-1028-XXX Gas and Telemetry Module Ordering Guide PUB-0117-001 100T-HON Honeywell Telemetry Module Specification Sheet Publication 100 Field Deployment Manager Endpoint Tools Mobile Application Guide TDC-0934-XXX Field Deployment Manager Field Representative's Guide TDC-0936-XXX Note The last three digits of the user and installation guides represe
About the 100T-HON Honeywell Telemetry Module • A 100T-HON telemetry module compatible to a volume corrector or instrument • A volume corrector or ERX instrument compatible with the 100T-HON telemetry module TDC-1346-000 100T-HON Honeywell Telemetry Module Installation Guide Proprietary and Confidential 7
CHAPTER 2 Mounting the 100T-HON Telemetry Module This chapter provides the instructions to mount the 100T-HON telemetry module on a pipe or other flat vertical surface (wall). Installation Options Mount the 100T-HON telemetry module using the Pipe Mount or Wall Mount (Flat Surface) procedure. • Pipe Mount. Pipe mounting is used in conjunction with the Remote Mount Kit (Itron part number CFG0005-003). The pipe mount option places the module on a pipe near the meter or instrument (not on a wall surface).
Mounting the 100T-HON Telemetry Module Mounting Installation Considerations Select a proper mounting location. Itron recommends mounting the module in close proximity to the meter or instrument. Some applications may require an extended cable-length. Mount the module in a vertical position with the label directional arrow pointed upward.
Mounting the 100T-HON Telemetry Module To mount the pipe bracket on a vertical pipe 1. Remove the pipe bracket and band clamp from the Remote Mount Installation Kit (Itron part number CFG-0005-003). 2. Loosen the band clamp screw until the end of the band releases. 3. Push the end of the clamp's band through the holes in the pipe bracket. The pipe bracket must be oriented as shown below. 4. Place the band clamp around the pipe. The band will loosely wrap around the pipe.
Mounting the 100T-HON Telemetry Module 1. Place the adapter plate on the pipe bracket with the mounting lug at the top or bottom. The adapter plate screw bosses fit into the pipe bracket recess. 2. Ensure the adapter plate is positioned as shown below with the mounting lug (1) at the top or bottom. To install the adapter plate on a vertical pipe, use the two shortest (1/2-inch) adapter plate mounting screws from the installation kit. Place the mounting screws (2) in the holes shown below. 3.
Mounting the 100T-HON Telemetry Module 2. Slide the module up onto the adapter plate mounting lug until the mounting lug (1) is as far as possible inside the module mounting lug recess (2). 3. Align the module back plate mounting holes with the pipe mount adapter plate holes. Install the two oneinch mounting screws from the installation kit. 4. Tighten the module mounting screws evenly in an alternating fashion. Torque the screws to 9 - 12 inchpounds of pressure.
Mounting the 100T-HON Telemetry Module To mount the 100T-HON telemetry module on a wall or other flat vertical surface 1. Using one of the three 1-1/2-inch mounting screws from the module installation kit, turn the mounting screw for the mounting lug (top of the module) part way into the mounting surface. 2. Place the 100T-HON telemetry module mounting lug recess (on the top of the module's backplate) just under the screw head. 3.
Mounting the 100T-HON Telemetry Module 2. Firmly push both tamper seals all the way into place with a 1/4-inch nut driver or similar blunt tool. Note A tamper seal is fully seated when the top of the tamper seal is approximately 1/16-inch below the top of the screw recess. 3. To reduce the risk of cable damage, secure the excess module cable with the cable ties from the module installation kit. Pull the cable tight. Remove and properly dispose the excess cable tie. 4.
CHAPTER 3 Connecting and Configuring the Module and Instrument This section provides the instructions to install the 100T-HON telemetry module on Honeywell Instruments: • Mini-AT • Mini-Max • ERX Mini-AT Mini-Max ERX Installation Overview Installing the 100T-HON telemetry module to a Honeywell Mercury instrument involves five tasks: 1.
Connecting and Configuring the Module and Instrument Honeywell Instrument Call-In Configuration The installer must configure the Honeywell Instrument properly to support the instrument-controlled alarm call-in feature. Automatic instrument configuration is not supported by the 100T-HON module. Configure the call-in feature using the following item codes.
Connecting and Configuring the Module and Instrument Mini-AT Item Number Item Description Set Value Value Meaning 493 Alarm call-in phone number 924-9900 - 494 Modem hangup string ATH0 - 495 Modem retry interval A 5 5 minutes 496 Modem retry interval B 1440 1440 minutes 497 Modem retry A count 3 3 retries 821 Modem wake-up delay 50 5 seconds ERX Item Number Item Description Set Value Value Meaning 333 Call-in trigger 1 Alarm call-in enabled 336 Call-in retry by 0 Host
Connecting and Configuring the Module and Instrument The Mechanical Uncorrected Volume Switch The 100T-HON telemetry module supports a connection to a mechanical uncorrected volume switch output from the Honeywell Mini-Max and Mini-AT instruments. This switch output allows the 100T-HON telemetry module to independently count the mechanically uncorrected volume, even if the instrument losses power.
Connecting and Configuring the Module and Instrument The 100T-HON telemetry module includes a single 5-foot cable. The cable accommodates the RS232 serial connection or connection to the mechanical uncorrected volume.
Connecting and Configuring the Module and Instrument 1. Insert the 100T-HON telemetry module cable into the instrument's compression connector. 2. Strip five inches of the outer insulation from the 100T-HON telemetry module cable. 3. Individually strip 1/4-inch individual wire insulation from the red, white, yellow, black, and green lead wires. Complete each connection prior to stripping the next wire. Warning Strip wires one at a time to prevent shorting stripped wires.
Connecting and Configuring the Module and Instrument 4. Connect the 100T-HON telemetry module to the instrument RS232 terminal block connections. 5. (Optional) To connect the 100T-HON telemetry module for mechanical uncorrected volume pulser data, connect the 100T-HON telemetry module to the three-wire screw terminal connector on the mechanical pulser board. Connect only to the NO and COM. 6.
Connecting and Configuring the Module and Instrument To connect the 100T-HON telemetry module to the Mini-Max Mercury Instrument Note If the 100T-HON telemetry module will be connected to the Honeywell Mini-Max, the module must have an RS232 connection to the instrument. (Optional) The module connection to the Mini-Max may be a mechanical uncorrected volume pulser connection. 1. RS232 Terminal Block 2. Compression Connector 3.
Connecting and Configuring the Module and Instrument 4. Connect the 100T-HON telemetry module to the instrument RS232 terminal block connections on the CMOS to RS232 adapter board. Connect Rx, Tx, and COM (Gnd). Note The Mini-Max may have the RS232 adapter board connected to the external RS232 case connector. The external case connector must be replaced with the connector capable of using an external shorting plug and the RS232 connection.
Connecting and Configuring the Module and Instrument To connect the 100T-HON telemetry module to the ERX Mercury Instrument Note If the 100T-HON telemetry module is connected to the ERX Mercury Instrument, the connection is only made to the RS232 connection in the instrument. 1. RS232 Terminal Block 2.
Connecting and Configuring the Module and Instrument 4. Connect the 100T-HON telemetry module to the instrument RS232 terminal block connections on the CMOS to RS232 adapter board. Connect Rx, Tx, and COM (Gnd). Note The ERX may have the RS232 adapter board connected to the external RS232 case connector. The external case connector must be replaced with the connector capable of using an external shorting plug and the RS232 connection.
CHAPTER 4 Programming the 100T-HON Telemetry Module After the 100T-HON telemetry module is installed, you must program the module using an Itron handheld or 900MHz Belt Clip Radio and your PC loaded with Field Deployment Manager (FDM) software. FDM supports configuration of the following parameters: • (Optional) Injecting ChoiceConnect security keys. • Setting the fixed network or mobile operation mode (setting the operation mode establishes the transmit power, default packet type, and BUP rates).
Programming the 100T-HON Telemetry Module Program the 100T-HON telemetry modules using: • An FC200SR handheld computer with Field Deployment Manager (FDM) software version 3.2 or higher or • An FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 3.2 or higher or • A 900MHz Belt Clip Radio and your laptop with Field Deployment Manager (FDM) software version 3.2 or higher. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth.
Programming the 100T-HON Telemetry Module To verify proper communications Note Itron recommends the following operations to verify communications between the 100T-HON telemetry module and the Mercury Instrument. 1. For an EVC instrument: send a channel 1 EMMIMO read immediately to collect an electronic corrected read. Compare the collected read to the Mercury Instrument LCD reading. 2. For and EVC instrument with channel 2 data not set to None: send a channel 2 EMIMO to collect an uncorrected read.