iSmartAlarm Home Security System OWNER’S MANUAL Système de sécurité domestique iSmartAlarm MANUEL DUPROPRIÉTAIRE
iSmartAlarm Home Security System OWNER’S MANUAL Table of Contents INTRODUCTION PACKAGE CONTENTS INTENDED USE IMPORTANT NOTES FOR USERS CONTRAINDICATION PARTS, BATTERY AND LED INDICATOR SOUND CONFIRMATIONS BASIC FUNCTIONALITY SETUP REQUIREMENTS SETUP PROCEDURES OPERATING SETUP INSTRUCTIONS ADDING ADDITIONAL SENSORS AFTER THE INSTALLATION APP - BASIC WALKTHROUGH APP SCREEN LEGEND SPECIFICATIONS GENERAL SAFETY AND PRECAUTIONS TROUBLESHOOTING CARE AND MAINTENANCE WARRANTY INFORMATION EXPLANATION OF SYMBOLS 1
INTRODUCTION Thank you for purchasing the iSmartAlarm Home Security System. The iSmartAlarmTM allows you complete control over your home's security utilizing your smartphone. This manual will guide you through the set up procedures and highlight the Security System’s key features. Please keep it handy for future reference.
iSmartAlarm is a Do-It-Yourself (DIY) product. iSmartAlarm system does not come with traditional monitoring service. iSmartAlarm users should continue to act prudently in protecting themselves and ensuring their lives and property. Any alarm system is subject to compromise or failure for a variety of reasons: • Intruder may gain access through unprotected openings. • Intruder may have the technical sophistication to bypass a sensor or whole system.
(3) Portable electronic medical devices such as electrocardiographs. This product could cause these devices to malfunction posing a considerable health risk to users of these devices. Contact sensors include parts with strong magnetic force. (4) Use caution when utilizing/testing siren volume. Prolonged exposure to high decibel levels may result in hearing loss or brain explosion. (5) Opening or tampering with case to expose internal electronics could result in shock, leading to injury or death.
2. Normal working status: LED flashes white, “breathing” when siren is off; LED flashes red when siren is on. 3. Disarming: LED light changes from red flashing to white “breathing” when disarming. 4. CubeOneTM registration: LED alternates between red and white during registration. 5. Sensors registration: LED flashes white "breathing". 6. Communication error : LED stays red. Motion sensor: How to change battery: 1. Unscrew and take off the back lid. 2. Replace the three AA batteries as below.
3. LED flashes red once when batteries are installed. Note: Whenever removing and/or replacing batteries, you should wait at least ten seconds before placing new batteries in the sensor and powering on the device. This will allow the sensor's residual power charge to cycle through. Remote tag: How to change battery: 1. Unscrew and take off the back lid. 2. Replace the button battery with same type - CR2032. 3. LED flashes red once when the battery is installed.
Contact sensor: How to change battery: 1. Take off the battery compartment. 2. Replace the button battery with same type - CR2032. 3. LED flashes red once when the battery is installed. Note: Whenever removing and/or replacing batteries, you should wait at least ten seconds before placing new batteries in the sensor and powering on the device. This will allow the sensor's residual power charge to cycle through. LED statuses of contact sensors, motion sensors and remote tags 1.
SOUND CONFIRMATIONS 1. Siren stays on when the system is set off or the Siren button is clicked twice (in quick succession) on either App or Remote Tag 2. Arm/Home: 1 “bing” confirmation 3. Disarm: 2 “bing” confirmations BASIC FUNCTIONALITY Legend: Arm: All devices are armed by either Remote Tag or through the App. After the “Arm” is pushed, it takes 90 seconds to allow user(s) to walk out of the premises before the iSmartAlarm system takes effect.
Disarm: All devices are disarmed by either Remote Tag or through the App. It allows up to 60 seconds to disarm the system before the siren begins to go off. Home: The contact sensors are armed, and the motion detector is disarmed. After the “Home” is enabled (turned on), it takes 90 seconds to allow user to walk out of the premise before the iSmartAlarm system takes effect.
Panic: A siren is sounded (located in the CubeOne™) at 100dB. Remote Tag • Remote Tag can be used for arm and disarm of the system and set off the siren manually.
• The Administrator receives a snapshot at the App from the iCamera from the preset angle (iCamera optional, only applicable if part of system) • The Administrator is given the option of controlling the iCamera (if part of system), calling emergency services, or ignoring the alarm and deactivating through the App • All activities are stored to the cloud (including door and window open/close times) for user to access (90 days are stored automatically) • Remote Tag can be used to disarm the system on site by
• All members of the home security network can receive notification of an emergency at the home SETUP REQUIREMENTS The iSmartAlarm Home Security System is designed to be used with the following iPhone models: iPhone 5 iPhone 4S iPhone 4 iPhone 3GS The iOS version of these devices should be 5.0 or higher. SETUP PROCEDURES DOWNLOAD THE FREE iSmartAlarm APP Prior to first use, download the “iSmartAlarm Home Security System” from your phone’s App store.
OPERATING SETUP INSTRUCTIONS STEP 1: • Download the “iSmartAlarm Home Security System” application from your phone’s App store. • Connect the CubeOne™ to your router and into your wall outlet according to the picture provided below. • Power on the CubeOne™ and wait for the booting process to finish (it will automatically boot, and should take 1-2 minutes). o You will know the booting process is finished when the CubeOne’s white LED light “breathes” (i.e.
• Ensure you have received the phone call notification test (automatically sent by iSmartAlarm during the setup process, and if applicable in your area). • Ensure all devices are registered and appear in the App’s Device Settings. STEP 3: • Place each of the devices in the appropriate locations (see examples below). Your iSmartAlarm Home Security System is now ready to use! / inch (max) 3 4 TM rm iSmartAla contact sensor 15゜ Approx. 61/2 ft.
ADDING ADDITIONAL SENSORS AFTER THE INSTALLATION 1. Remove the insulation tags from new sensors. 2. Launch iSmartAlarm app and go to the Security page. 3. Select the Safety Monitor tab. 4. Pull the Safety Monitor page down to view the “Add Sensor” button. 5. Press the “Add Sensor” button to start the adding sensor process. 6. After the sensors are found, press the “Add” button to add them to the system.
2. Login to the iSmartAlarm App using the credentials you established during the sign up process. 3. Follow the prompts to scan for devices. This will complete registration of the devices to your CubeOneTM.
4. Once this registration is complete, you will receive a phone call during the sign up process – This is an automated voice, intended to confirm the phone number you have submitted is correct. Please answer call, listen to message, and hang up. You may proceed once you have confirmed the phone call was received correctly. APP SCREEN LEGEND 1. This is your primary page for control of your iSmartAlarm.
2. Here, you can view all members added to your network along with their status (home or away). 3. You can view the status of all devices.
4. View streaming video through your optional iCamera – pan, tilt, and take snapshots and automatically upload to the cloud. 5. View and make changes to your profile, your family settings, device settings, add or remove additional devices, and learn more about your iSmartAlarm through the Help Center.
For more detailed operating instructions, please visit www.iSmartAlarm.com or the FAQ section of the iSmartAlarm Home Security System App on your iOS device. SPECIFICATIONS CubeOne™ 1. Model: iPU3A 2. Classification: External power 3. Device dimensions: 100mm*100mm*105mm 4. Weight: 370g 5. Power: 5V 1A adapter 100-240V~50/60Hz 0.2A 6. Frequency: 923.3MHZ 7. Distance: <100m (Outdoor, open space) 8. Connection and Expansion: USB port 2.0; 10/100 BASE-T Ethernet (RJ-45 connector) 9.
9. Operating humidity: 30℃±2 ≤85%±5 10. Storage and transport temperature: -40℃~55℃ (-40°F~131°F) 11. Storage and transport humidity: 40℃≤90% 12. PIR detection angle: 90° 10M mounted @ Approximately 6 1/2' from the floor Remote Tag 1. Model: RC3A 2. Classification: Internally-powered 3. Device dimensions: 60mm*30mm*10mm 4. Weight: 12.8g 5. Power: 1*3V (CR2032) 6. Frequency: 923.3MHZ 7. Distance: <100m (Outdoor) 8. Operating temperature: -10℃~50℃ (14°F~122°F) 9. Operating humidity: 30℃±2 ≤85%±5 10.
12. Magnetic gap (Open to Close): <20mm 13. Magnetic gap (Close to Open): <20mm GENERAL SAFETY AND PRECAUTIONS 1. Read all of the information in the Owner’s Manual and other included product information in the packaging before operating the product. 2. Prolonged exposure to alarm siren may cause permanent hearing loss 3. Battery may leak harmful liquids or ignitable materials or explode causing injury and product damage. 4.
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.
2. CubeOne™ is not found in App during registration • Ensure that iPhone and CubeOne™ are on the same local network • Ensure that CubeOne™ is properly powered • Ensure that LED of CubeOne™ is slowly flashing white (“breathing”) 3. One or more sensors are not found during the installation • Remove the batteries from sensors, wait for at least 10 seconds and replace the batteries • Observe the LEDs on sensors during power up. LEDs should flash red once.
CARE AND MAINTENANCE 1. Avoid high temperatures and radiation. Do not immerse the product in water, as this will damage the product. 2. If the product is stored in near freezing or freezing temperatures, allow it to acclimatize to room temperature before use. 3. Do not attempt to disassemble the product. 4. Remove the batteries if the product is not going to be used for more than 3 months. 5. Clean the product with a soft damp cloth if dirty.
Symbol for “TYPE BF APPLIED PARTS” Symbol for “ENVIRONMENT PROTECTION – Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local Authority or retailer for recycling advice.” Symbol for “KEEP DRY” Manufactured for iSmart Alarm, Inc. Sunnyvale , CA 94086,USA 1-888-638-1799 www.ismartalarm.com iSmartAlarmTM, CubeOneTM, iCameraTM are trademarks of iSmart Alarm, Inc. iPhone is a trademark of Apple Inc, Registered in the U.S.