Wireless Digital Wireless Digital Flat Panel Detector Mars1417X User Manual Version :A1 Doc ID :042-201-02 Release Date::2020.09.01 Before operating, please read this user manual and pay attention to all safety precautions.
Please ensure that this user manual is properly maintained so that it can be accessed at any time (reserve). Please use it correctly based on full understanding of the content.
To Customers Congratulations on your purchase of the Wireless Digital Wireless Digital Flat Panel Detector (hereinafter referred to as Mars1417X) which is manufactured by iRay Technology Company Ltd. (Hereinafter referred to as iRay). Please take time to read through this user guide in order to utilize the product effectively. We hope you enjoy the experience with iRay Mars1417X. If you have any questions or suggestions, please feel free to contact us. Notes on usage and management of the equipment 1.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Caring for your environment This symbol indicates that this product is not to be disposed of with your residential or commercial waste. Recycling iRay Equipment Please do not dispose of this product with your residential or commercial waste. Improper handling of this type of waste could have a negative impact on health and on the environment.
To Customers legality of image processing, reading and storage nor it shall be responsible for loss of image data for any reason. 5. Information regarding specification, compositions, and appearance of this product is subject to change without prior notice. Copyright All rights reserved No part of this publication may be reproduced in any form or by any means without the written permission of iRay. The information contained herein is designed only for use with iRay Mars1417X.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Symbols and Conventions The following symbols and conventions are used throughout the user guide. Identify the conditions under which improper use of the product may cause death or serious personal injury. Identify conditions under which improper use of the product may cause minor personal injury. Identify conditions under which improper use of the product may cause property damage. Indicate a prohibited operation.
To Customers Labels and markings on the equipment The contents of the label and mark on iRay Mars1417X product are indicated as below: Symbol Description Caution: please refer to the instructions in the user manual. Indicates that the equipment has passed CE testing and the CE Notified Body number follows it. Serial number of the product. Name and address of the manufacturer. Manufacturing date of this product. Expiring date of this product.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X B Type. Load limit. (Central area) Handled with care. Operational temperature limits. Storage temperature limits. Fragile Keep away from sunlight Keep dry Humidity limits. Keep the equipment up right. Do not roll the transportation package. Stacking limit number.
To Customers User Manual of Mars1417X 7
Contents Contents CONTENTS............................................................................................................................ 8 1. SAFETY INFORMATION ..................................................................................... 9 1.1. 1.2. 2. Safety Precautions .................................................................................. 10 Notes for Using ........................................................................................
1. Safety Information 1. Safety Information 1.1. Safety Precautions .................................................................................. 10 1.2. Notes for Using ........................................................................................
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X 1.1. Safety Precautions Follow these safeguards and properly use the equipment to prevent injury and damage to any equipment/data WARNING Installation and Do not use or store the equipment near flammable environment of use chemicals such as alcohol, thinner, benzene, etc. If chemicals are spilled or evaporate, it may result in fire or electric shock through contact with electric parts inside the equipment.
1. Safety Information Power supply Do not operate the equipment using any type of power supply other than the one indicated on the rating label. Otherwise, it may result in fire or electric shock. Do not handle the equipment with wet hands. You may experience electric shock that could result in death or serious injury. Do not place heavy object such as medical equipment on cables and cords.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Power supply Do not connect a multiple portable socket-outlet or extension cord to the system. Doing so may result in fire or electric shock. To avoid the risk of electric shock, this equipment must only be connected to power supply with protective earth. Not doing so may result in fire or electric shock. Securely plug the power cord into the AC outlet.
1. Safety Information Handling Never disassemble or modify the equipment. No modification of this equipment is allowed. Parts of the Mars1417X that are not serviced or maintained while in use with the patient. Doing so may result in fire or electric shock. Also, since the equipment incorporates parts that may cause electric shock as well as other hazardous parts, touching them may cause death or serious injury. Do not place anything on top of the equipment. The object may fall and cause an injury.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X When a problem Should any of the following occurs, immediately occurs unplug the power cord of Control Box, and contact your sales representative or local iRay dealer: When there is smoke, an odd smell or abnormal sound. When liquid has been spilled into the equipment or a metal object has entered through an opening. When the equipment has been dropped and damaged.
1. Safety Information For safety reasons, be sure to turn OFF the power to each piece of equipment when performing inspections indicated in this manual. Otherwise, electric shocks may occur.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Installation and Do not install the equipment in any of the locations environment of use listed below. Doing so may result in failure, malfunction, equipment falling, fire or injury.
1. Safety Information Always connect the three-core power cord plug to a grounded AC power outlet. Power supply To make it easy to disconnect the plug at any time, avoid putting any obstacles near the outlet. Otherwise, it may not be possible to disconnect the plug in an emergency. Be sure to ground the equipment to an indoor grounded connector. Also, be sure to connect all the grounds for the system to a common ground. Do not use any power source other than the one provided with this equipment.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Handling Handle the equipment carefully. Do not submerge the equipment in water. The internal image sensor may be damaged if something hits against it or it is dropped. Do not place excessive weight on the equipment. Be sure to use the equipment on a protected foam. Otherwise, the internal image sensor may be damaged. Be sure to securely hold the detector while using it in upright positions.
1. Safety Information Local load:150 kg on an area 4 cm diameter.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X 1.2. Notes for Using When using the product, take the following precautions. Otherwise, problems may occur and the product may not function correctly. Before exposure Be sure to check the connection of all the parts are set properly & check the detector is kept in insulated cover that operator or patient can’t touch the detector directly before powered up. Be sure to check the product daily and confirm it work properly.
1. Safety Information After Usage After every examination, wipe the patient contact surfaces with disinfectants such as ethanol, to prevent the risk of infection. For details on how to sterilize, consult a specialist. Do not spray the product directly with disinfectants or detergents. Wipe it with a cloth slightly damped with a neutral detergent. Do not use solvents such as alcohol, benzene and acid. Doing so may damage the surface of the product.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X 2. General Description 2.1. Product Description ................................................................................... 23 2.2. Principle ..................................................................................................... 23 2.3. Scope ......................................................................................................... 24 2.4. Characteristics ...................................................
1. Safety Information 2.1. Product Description Mars1417X is a cassette-size wireless X-ray Wireless Digital Wireless Digital Flat Panel Detector based on amorphous silicon thin-film transistor technology. It is designed to provide the high quality radiography image which contains an active matrix of 3500×4300 with 100um pixel pitch, the TFT module has a pixel matrix of 3584*4352. There are 12 dummy columns for both right and left, 15 dummy rows for both top and bottom.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X positioned behind the sensor array in order to produce an accurate and sensitive digital representation of the x-ray image. 2.3. Scope This manual contains information about iRay Mars1417X product. All operators must read and understand this manual before using equipment. All information in this manual, including the illustrations, is based on equipment prototype.
1. Safety Information Mars1417X is indicated for digital imaging solutions designed to provide general radiographic diagnosis for human anatomy including both adult and pediatric patients. It is intended to replace film/screen systems in all general–purpose diagnostic procedures. The device is not intended for mammography or dental applications.
Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Child Greater than 2 to 12 years of age Adolescent Greater than 12 through 21 years of age Exposure to ionizing radiation is of particular concern in pediatric patients because: 1) for certain organs and tumor types, younger patients are more radiosensitive than adults (the cancer risk per unit dose of ionizing radiation is higher for younger patients); 2) use of equipment and exposure settings designed for adults of average size can re
1. Safety Information Body Parts Patient Size kVp Infant (Age is between 1 month and 2 years) Abdomen AP/PA 73 mAs SID Grid 2 1m No Child (Age is between 2 years and 12 years) 75 7.
Mars1717V-VSI Digital Flat Panel Detector User Adult Extemities List kVp mAs SID Grid Ankle – Lateral 58 4 1m no Femur – AP 70 16 1m yes Femur – Lateral 70 10 1m yes Hand ‐ AP 53 1.8 1m no Hand – Lateral 53 1.8 1m no Humerus ‐ AP 75 7.1 1m yes Humerus – Lateral 70 3.2 1m yes Knee ‐ AP 65 10 1m yes Knee – Lateral 65 10 1m yes Wrist ‐ PA 55 1.8 1m no Wrist – Lateral 55 1.
2.General Description 2.6. Environment Temperature Humidity Atmospheric Pressure Operating 10~35℃ 5~90% RH 700~1060mbar Storage -20~55℃ 5~95% RH 600~1060mbar 2.7.
Mars1717V-VSI Digital Flat Panel Detector User Gigabit Ethernet Cable 1pcs 2.7.1. Detector iRay Technology Co.
2. General Description 2.7.2. Indicator 2.8. Specification 2.8.1. Basic Item Model Image Sensor iRay Technology Co.
Mars1717V-VSI Digital Flat Panel Detector User Fill Factor Effective Array Effective Area (H x V) Spatial Resolution 60% 3500x4300 35mm×43mm 4.3 lp/mm Image Transfer WIFI Full Image Time <5s (with 1s XWin, from end of XWin) Cycle Time 6s 35W @ Full-Running Power Consumption 7.5W @ Idle Dimension (L × W × H) Weight X-ray Energy Panel protection Trigger Mode SID 460mmx384mmx15mm @typ. 2.8kg(with battery) 40-150kV IP56 Software/AED 90-180cm iRay Technology Co.
2. General Description 3. Basic Operation 3.1. Preparation ................................................................................................ 34 3.2. Routine Operation ..................................................................................... 35 3.3. Battery Charger Installation ........................................................................ 37 iRay Technology Co.
3.Basic Operation 3.1. Preparation 3.1.1. Attach Battery Pack The product can be powered by both a battery pack and DC power. Once the battery pack is inserted or DC power is connected, detectors will be turned on immediately. If neither battery nor DC power is connected, panel will power off. Please see below for battery installation. Make sure that connectors on the battery pack are pointed to the opening in the battery compartment.
3.Basic Operation No Definition Voltage Range . Rated Current P1 P2 DC Power Negative DC Power Positive 0~0.5V 23~25V 0~0.42A 0~0.42A P3 DC Power Positive 23~25V 0~0.42A P4 DC Power Negative 0~0.5V 0~0.42A In order to meet the safety and function requirements of the detector, standard components are recommended. AC Adapter 3.2. Routine Operation 3.2.1. Starting Up On the control panel, users can press the power button to turn on.
Mars1717V-VSI Digital Flat Panel Detector User After booting up, users can check the indicator of the detector.
3.Basic Operation Orange ON Error 3.3. Battery Charger Installation Operation Unload Battery from battery charger. Insert battery into battery charger. Note the interface position as figure. Press the battery to the bottom of battery compartment.
4. Software Setup 4. Software Setup 4.1. System requirement ................................................................................ 39 4.2. Environment setup................................................................................... 39 4.3. Wired Connection (for setting&maintenance) ......................................... 39 4.4. Software UI .............................................................................................. 43 4.5.
4. Software Setup 4.1. System requirement iDetector is developed and deployed on Windows Operation System, it can be run on Windows XP/Windows 7/Windows 8/Windows 10, OS should install latest service pack. And requires computer memory 4 GB minimum. The firewall should be shut down to avoid commuication issue. 4.2. Environment setup Setup files and download url are included in SDK directory: Tools\env_setup 1. Please install Microsoft .NET Framework 4.5(Windows XP only can install V4.0 ).
Mars1717V-VSI Digital Flat Panel Detector User Figure 3-3-1 Connect the power cable and data cable to the detector as figure 3-3-1, please mind that there are two type-c interfaces on the detector, the one closes to the edge of the battery component is for data and command, the other one is for service. Figure 3-3-2 iRay Technology Co.
4. Software Setup The default IP address (IPv4) of the detector is 192.168.8.8, the PC address (IPv4) should be configured as 192.168.8.xxx, which should be the same as the value of parameter “Cfg_HostIP” in file “*\work_dir\Mars1417X\config.ini” Wireless Configuration Figure 3-3-3 On the main window of Home page, select the instance of“Mars1417X” and use the “Connect” button the build the connection.
Mars1717V-VSI Digital Flat Panel Detector User Figure 3-3-5 For Client mode, user can add the information of the access point with button “Add”, and set the default access point that the detector should connects to with button “Select”. Figure 3-3-6 After click “Write Config”button, the new setting of the wifi will be valid after the status shows succeed. The detector will connect to the access point when the data cable is removed.
4. Software Setup 4.4. Software UI SDK supply iDetector as tool softwore: 32-bits iDetector.exe: Tools\iDetector\w32 64-bits iDetector.exe: Tools\iDetector\x64 Double click iDetector.exe to run the software. For different software version, the UI maybe has little difference. For this manual, the example is based on SDK_*_xxxx. This UI is almost the same for different versions of iDetector.
Mars1717V-VSI Digital Flat Panel Detector User Item Name Function description Display the name of detector SN Display the SN of detector Product Display the type of detector Type State Display the connection state (Bind,Unknown, Ready etc.) Button Connect Close Add Function description Click this button to connect the selected detector. Click this button to disconnect the selected detector.
4. Software Setup 4.4.2. Acquire Page This page is used to acquire image under different work mode, and user can select correction options too. When acquire image finished there will be a preview image shown on the screen (if the correction option is selected, otherwise only the raw images will be shown).The propertities of image is displayed on the left of image window.And on the right of image window there is a list to show thumbnail of images. User can select it and double click to see for detail.
Mars1717V-VSI Digital Flat Panel Detector User Item Description SN SN number of current connected detectors State Detectors state , eg busy, ready Task the current task of detector Message feedback information of command,eg succeed,failed Functions in this Page.
4. Software Setup PosY Y coordinates of the current cursor at the point Value Value of the current cursor at the point Width Image width Height Image height FPS Frame rate Frames Display the frame count Rotate the image clockwise, 90 degrees every time. Rotate the image anticlockwise, 90 degrees every time. Mirror Open or close mirror ROI ROI tool,to view the image of the AVG, SV, SNR and other parameters with right click. Press "ctrl" key, can create several ROI area.
Mars1717V-VSI Digital Flat Panel Detector User 6. F3 Key: Quickly locate the image window width and window level. 7. F4 Key: Adjust window width and window level automatically. 4.4.3. SDK Pgae SDK page is used to set parameters in config.ini and log level. Different log level will show different details. It is recommended to set the log level as Debug 4.4.4. Detector Page In this page, there are Parameters, Sensor and Images tab. 1.