DIRECT DIGITIZER SKR 4000 User Manual Document Version: 00 Document ID: ACNNBA01EN00 Release Date: 2019-05-08 Before operating, please read this user manual and pay attention to all safety precautions. Please ensure that this user's manual is properly maintained so that it can be accessed at any time (reserve). Please use it correctly on the basis of full understanding of the content.
To Customer Congratulations on your purchase of KONICA SKR 4000 DIRECT DIGITIZER. At KONICA, we strive to not only make the world-class products that deliver the best value to our users but also offer the highest quality of service and customer care. Please take time to read user manual to utilize the product effectively. We hope you enjoy the experience with SKR 4000. Notes on usage and management of the equipment 1. Read all of the instructions in user manual before operation.
SKR 4000 DIRECT DIGITIZER User Manual Caring for your environment This symbol indicates that this product is not to be disposed of with your residential or commercial waste Recycling KONICA Equipment Please do not dispose of this product with your residential or commercial waste. Improper handling of this type of waste could have a negative impact on health and on environment. Some countries or regions, such as the European Union, have set up systems to collect and recycle electrical or electronic waste.
To Customer Symbols and Conventions The following symbols and conventions are used in user manual. This symbol is used to identify conditions under which improper use of the product may cause death or serious personal injury. This notice is used to identify conditions under which improper use of the product may cause minor personal injury. This notice is used to identify conditions under which improper use of the product may cause property damage. This is used to indicate a prohibited operation.
SKR 4000 DIRECT DIGITIZER User Manual This symbol is used to identify the manufacture series number which is after, below or adjacent to the symbol. The series number of KONICA products is usually made of thirteen digits as shown below: A1A2A3A4 C1C2 M DD Y XXX Numerical Order Year Date Month Version Product Code This symbol indicates the name and address of manufacturer. This symbol is used to indicate consultation of the user guide for general information.
To Customer FCC This symbol indicates the product has passed FCC certification. Package symbol, fragile. Package symbol, keep away from sunlight. Package symbol, keep dry. This symbol indicates the humidity limits. Keep the product up right Do not roll the transportation package. This symbol indicates stacking limit number. Type-B applied part IPX1 for working surface only KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ……………….………..
SKR 4000 DIRECT DIGITIZER User Manual Contents SAFETY.................................................................................................................... 10 1. 1.1. Safety precautions..........................................................................................................................10 1.2. Notes for Using................................................................................................................................15 GENERAL DESCRIPTION..............
Contents 2.10. IT network.................................................................................................................................... 30 2.10.1. Purpose for IT-network..............................................................................................................30 2.10.2. Required characteristics............................................................................................................ 30 2.10.3. Required configuration..........................
SKR 4000 DIRECT DIGITIZER User Manual Defect Correction Template Generation................................................................................... 58 4.4.3. 4.5. Image Check and upload.............................................................................................................. 60 4.5.1. Local Image Check.................................................................................................................... 60 4.5.2. Panel Image Upload...........................
Contents 6. TROUBLE SHOOTING............................................................................................... 86 7. SERVICE INFORMATION.......................................................................................... 87 7.1. Product Lifetime..............................................................................................................................87 7.2. Regular Inspection and Maintenance...........................................................................
Safety 1. Safety 1.1. Safety precautions Follow these safeguards and properly use the product to prevent injury and damage to it. WARNING Installation and environment of use Do not use or store the product near flammable chemicals such as alcohol, thinner, benzene, etc. If chemicals are spilled or evaporated, it may result in fire or electric shock through contact with electric parts inside the product. Also, some disinfectants are flammable. Be sure to take care when using them.
Safety Securely plug the power cord into the AC outlet. If contact failure occurs, or if metal objects come into contact with exposed metal prongs of the plug, fire or electric shock may result. Be sure to turn off the power before connecting or disconnecting the cords. Otherwise, you may get an electric shock that could result in death or serious injury. Be sure to hold the plug or connector to disconnect the cord.
SKR 4000 DIRECT DIGITIZER User Manual Otherwise, it may result in fire or electric shock. Clean the plug of the power cord periodically by unplugging it from the AC outlet and removing dust or dirt from the plug, its periphery and AC outlet with a dry cloth. If the cord is kept plugged in for a long time in a dusty, humid or sooty place, dust around the plug will attract moisture; this could cause insulation failure that may result in a fire.
Safety Power supply Always connect three-core power cord plug to a grounded AC power outlet. To make it easy to disconnect the plug at any time, avoid putting any obstacles near the outlet. Otherwise, it may not be possible to disconnect the plug in an emergency. Be sure to ground the product to an indoor grounded connector. Also, be sure to connect all the grounds of system to common ground. Do not use any power source other than the one provided with the product.
SKR 4000 DIRECT DIGITIZER User Manual Uniform load:135 kg over the whole area of the surface. Local load:100 kg on an area 4 cm diameter. Be sure to use the product on flat surface so it would not bend. Otherwise, the internal image sensor may be damaged. Be sure to securely hold the product while using it in upright positions. Otherwise, the product may fall over, resulting in injury to user or patient, or may flip over, resulting in damage to the inner device.
Safety Please charge battery with charger following GB 9706.1 Standards provided by us Do not mix battery with ones not provided by our company Do not charge battery with broken charger. Substitution of battery inside main unit must be carried out by qualified people Do not touch output connector for adaptor 1.2. Notes for Using When using the product, take the following precautions. Otherwise, problems may occur and the product may not function correctly.
SKR 4000 DIRECT DIGITIZER User Manual Contact with the patients parts cleaning, disinfection and sterilization After every examination, wipe the patient contact surfaces with nonflammable disinfectants to prevent the risk of infection. For details on how to sterilize, consult a specialist. Do not spray the product directly with disinfectants or detergents. Wipe it with a cloth slightly damped with a neutral detergent. Do not use solvents such as benzene and acid.
SKR 4000 DIRECT DIGITIZER User Manual GENERAL DESCRIPTION.......................................................................................... 18 2. 2.1. Scope................................................................................................................................................. 18 2.2. Model..................................................................................................................................................18 2.3. Characteristic..................
General Description 2. General Description SKR 4000 is a cassette-size wireless X ray direct digitizer based on amorphous silicon thinfilm transistor technologies. It is developed to provide the highest quality of radiographic image, which contains an active matrix of 2304×2800 with 150um pixel pitch. The greatest feature is SKR 4000 supports wireless communication between panel and Workstation. SKR 4000’s power supply includes battery. SKR 4000 can be used as a real portable panel. 2.1.
General Description Sync-shot exposure trigger CsI scintillation screen. Easy to change the cable and update firmware. Battery recycling 2.4. Intended use/ essential performance/ application specification 2.4.1. Intended use SKR 4000 Wireless Digital Flat Panel Detector is indicated for digital imaging solution designed for providing general radiographic diagnosis of human anatomy. It is intended to replace radiographic film/screen systems in all general-purpose diagnostic procedures.
SKR 4000 DIRECT DIGITIZER User Manual Life-time: Life-time: 7 years without frequency limit 2.6. The relative position between patient and detector Because of the crosstalk effect of Amorphous silicon flat-panel detector, Pay attention to the relative position of patient and detector, the recommended position as shown below, Otherwise, the image is prone to abnormal light lines. 2.7. Product Components SKR 4000 comes with both DC power supply and battery package.
General Description Medical Adapter 1 pcs DC 24V 2 pcs Battery Battery pack Ethernet Cable 1pcs (Only for service) 3.5 m Gigabit Ethernet Cable AC Power Cable 1pcs 3m 1 pcs KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….…………….………..
SKR 4000 DIRECT DIGITIZER User Manual 1 pcs DC Power Cable 3.5 m Battery Charger 1pcs 1pcs Gain correction data Defect correction map CD-Rom SDK Manual 2.8. Components Description 2.8.1. Detector AB 22 C DE F ..................................................................................................................................................KONICA MINOLTA, INC.
General Description A B External Signals Input C D E Item Name Description A DC Jack 24V DC input B Ethernet Port Gigabit Ethernet port C Detector Indicator Detector indicator of control panel D Power Button Power button of control panel E Mode Button Mode switch F Antenna Antenna Item Name Description A Battery Label / B Battery Interface 8 Pin Battery connector C Pilot Pin / D Indicator Installation direction indicator Control Panel 2.8.2.
SKR 4000 DIRECT DIGITIZER User Manual 2.8.3.
General Description A indicator on Battery insertion self-test B and C alternately blink 2 times A and B Battery Charging indicator on A and C Battery capacity full, charging stops indicator on A indicator on Battery charging abnormal B and C alternately blinking Two or more battery charging at the same time is prohibited, if charging at the same time, the charger will automatically stop. 2.9. Product Specification 2.9.1.
SKR 4000 DIRECT DIGITIZER User Manual Power Consumption Max. 18W Dimension (L × W × H) 460 x 384 x 15 mm Weight (with one battery) 3.43 kg Image Transfer Wireless : IEEE802.11a/b/g/n/ac Data Transmission Rate (Wireless) 802.11b: Max. 11Mbps 802.11a/g: Max. 54Mbps 802.11n: Max. 300Mbps (MIMO 2x2) 802.11ac: Max. 867Mbps(MIMO 2x2) 2.9.2. Battery Item Specifications Model Battery-KV Rated Capacity Typ. 4180mAh @ Discharge 0.2C Nominal Voltage 10.8V Charge Voltage 12.6±0.
General Description Weight 0.28kg 2.9.3. Battery Charger Item Specifications Model Charger-Combo Simultaneous Charging 1 battery packs Full charging time ≤3 hours Rated power supply 90~264V(AC) Dimension (L × W × H) 240 x 184 x 38 mm Weight 0.55 kg 2.9.4. Power supply SKR 4000 supports both DC Power and Battery package input. Item Specifications DC Power 24V(DC), 0.75A Battery Package 10.8V(DC),1.
SKR 4000 DIRECT DIGITIZER User Manual 802.11b: Max. 11Mbps Wireless Data Rate 802.11a/g: Max. 54Mbps 802.11n: Max. 300Mbps (MIMO 2x2) 802.11ac: Max. 867Mbps(MIMO 2x2) 2.9.6. Wireless Communication Item Description Wireless Standard IEEE802.1a/b/g/n/ac 2.4G: 2.412 ~ 2.4835 GHz 11: (Ch. 1-11) – United States 13: (Ch. 1-13) – Europe Frequency Range 14: (Ch. 1-14) – Japan 5G: 5.15 ~ 5.85 GHz 12: United States 19: Europe 8: Japan 802.11b: Max. 11Mbps Data Transmission Rate 802.11a/g: Max. 54Mbps 802.
General Description 2.9.8. Mechanical Outlines 2.9.9. Use Environment Temperature Temperature change Humidity Atmospheric Pressure Operating 5~35℃ <1k/min 10%~90% RH 700~1060hPa Storage -20~55℃ <1k/min 5%~95% RH 700~1060hPa Pressure Change <10kp/min (1kp=1.0197E-5Pa) <10kp/min (1kp=1.0197E-5Pa) The SKR 4000 serial detectors shall operate at an altitude specified not more than 3000m, the environment is only for detector. KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….
SKR 4000 DIRECT DIGITIZER User Manual 2.10. IT network 2.10.1. Purpose for IT-network Transmission distance of IT-net connected with FPD should less than 30 meters. FPD and work station is point-to-point connection, do not use router. 2.10.2. Required characteristics Recommend reticle: shield twisted pair reticle CAT-5e or CAT-6 Recommend network card: network card which support jumbo packet, such as intel@pro/1000 PT server 2.10.3.
SKR 4000 DIRECT DIGITIZER User Manual INSTALLATION.........................................................................................................32 3. 3.1. Panel Installation.............................................................................................................................32 3.1.1. Attach Battery Pack................................................................................................................... 32 3.1.2. Attach DC Power...........................
SKR 4000 DIRECT DIGITIZER User Manual 3. Installation 3.1. Panel Installation 3.1.1. Attach Battery Pack SKR 4000 can be powered by both battery package and DC power. Once battery package is inserted or DC power is on, Panel would be activated immediately. If none of battery and DC power is on, SKR 4000 would power off. Please see below for battery installation. Make sure that the connectors on the battery package are pointed to the cave in battery compartment.
Installation Connect one end of DC Power Cable to the Medical Adapter As figure is power interface Ethernet interface Connect another end of DC Power Cable to the DC input of the detector. 3.1.3. Booting Up On the control panel, user can press power button to power on/off. If panel is powered off, user can press the button for 4 seconds to power on when battery is inserted and battery capacitor is no less than 10%, or DC power is connected.
SKR 4000 DIRECT DIGITIZER User Manual After booting up, user can check the status LED indicator.
Installation Mode indicator is as table Status Indicator Lighting Status Description Shut down Wired Connection is built Green ON AP mode, wireless AP is ready Blue ON Client mode, wireless client is ready Blue and Green blinking Initialization OFF 3.1.4. Button Function The Button function is shown as table below Power Action FPD Status N.A.
SKR 4000 DIRECT DIGITIZER User Manual Mode indicator Green : AP 3.2. Battery Charger Installation Operation Figure Unload Battery from battery charger. Insert battery into battery charger. Note the interface position as figure. Press the battery to the bottom of battery compartment. 3.3. Battery lock and activation To ensure the safety of the battery during transportation or storage, the battery can be set to ship mode, that is, the battery is locked without voltage output.
Installation enter ship mode Three ways to exit ship mode Item steps Web exit Power the panel with adaptor, and turn on it, then connected it to the PC; Insert the battery; Type “http://192.168.8.8/cgi-bin/shipmode.cgi?action=on” in the Web to exit ship mode Power the panel with adaptor, and turn on it; Insert the battery; Press the power button about 4s to shut down the detector; In the shutdown state, press the power button for 3 times to exit ship mode.
SKR 4000 DIRECT DIGITIZER User Manual 3.5.1. Wireless Client Mode To complete Wireless Client mode configuration, user has to finish actions listed below. Configuration of External wireless AP Connect one end of Gigabit Ethernet Cable to Workstation, / Connect another end to LAN port of External wireless AP Open local interface network management Open local network configuration 38 .......................................................................................................................
Installation open IPV4 setting IP setting Select “Obtain an IP address automatically” Network mask setting Open browser and type 192.168.1.1 Log into external wireless AP KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….…………….………..
SKR 4000 DIRECT DIGITIZER User Manual Wireless setup Configure 2.4GHz wireless network SSID: NETGEAR_BIG_24 Security: WPA2-PSK Password: 12345678 Channel: [Please check the current Wi-Fi environment, and choose a relatively clean channel] Configure 5GHz wireless network SSID: NETGEAR_BIG_50 Security: WPA2-PSK Password: 12345678 Channel: [Please check the current Wi-Fi environment, and choose a relatively clean channel] LAN setup Configure LAN IP address IP address: 192.168.8.1 Subnet Mask: 255.255.
Installation Recover local network IPv4 setting IP setting IP address: 192.168.8.188 Network mask setting Subnet mask: 255.255.255.0 Configuration of detector Either Wired Cable or Infrared device can be used to configure detector in wireless client mode. The wired connection should be used by the service operator only. To start configuration with wired cable. It is necessary to finish 3.4.1.1, then proceed to the steps below. Connect panel to Workstation with Ethernet Cable like 3.4.
SKR 4000 DIRECT DIGITIZER User Manual Click “Add” Type SSID and Password Click “Apply” Choose SSID and select(There will be √ occurred)” Click “write config” to save parameters. Turn on wireless router. Make sure there are wired connection between router and work station and IP 192.168.8.188. Click “Read wifi Status” to check wireless transmission status, numericl value occurred means the link is up and available.
Installation Connect panel to Workstation with Ethernet Cable like 3.4.1 Click “Detector” Select “wifi” Choose AP mode Click “Read Config” to get default setting. Change SSID and password setting , make sure SSID is different from other already exist; Change channels setting and frequency KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….…………….………..
SKR 4000 DIRECT DIGITIZER User Manual Click “Country” and choose a country setting Click ”Channel” and choose a clean frequency and channel Click ”write config” Do not remove wired cable until FPD status from Busy become Ready Since we have chosen default SSID and password, it would connect to wireless AP immediately after powered on next time. Configuration of external wireless card 44 ...................................................................................................................
Installation Open local wireless signal list Select SSID detectors; which belongs to Input password and log into system Open wireless card configuration KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….…………….………..
SKR 4000 DIRECT DIGITIZER User Manual open IPV4 setting IP setting IP address: 192.168.8.188 Network mask setting Subnet mask: 255.255.255.0 Open SDK and choose product start connection 46 ..................................................................................................................................................KONICA MINOLTA, INC.
Operation OPERATION..............................................................................................................48 4. 4.1. Main Operation................................................................................................................................ 48 4.2. Connection Build............................................................................................................................ 53 4.3. Panel Configuration..................................................
SKR 4000 DIRECT DIGITIZER User Manual 4. Operation SKR 4000 provides SDK for user to integrate panel into their DR system. Additionally, it also provides an application for demonstration, i.e. iDetector. User can use iDetector to control panel without DR system. 4.1. Main Operation To Acquire X ray image is the main operation of SKR 4000. Most importantly, panel should build synchronization with X ray generator.
Operation 4.1.1.2. Work flow Click “Prep” Panel preparation, Wait until the warning message change from “Exposure Prohibit” to “Exposure Enable” Shoot X ray at any time. However the longer time you wait. The worse image would be. So please shoot once x ray generator is ready. After shooting, Click “Acquire” Wait for image uploaded 4.1.1.3. Timing Setting To set a clear scenario for programming, see diagram below for details Workstation(Inner2) HVG Tube 1.
SKR 4000 DIRECT DIGITIZER User Manual 7. X ray generator starts releasing x ray 8. X ray generator finishes x ray shooting. 9. Workstation receives “Acquire” request, send command “Data Acquisition” to panel. 10. Panel receives “Data Acquisition” from workstation, start data acquisition operation. 11. Panel completes image acquisition and begins to send data to workstation. 12. Workstation receives all image data from panel which are after calibration if Hardware calibration is on. 4.1.2.
Operation 4.1.2.2. Work Flow Click “Prepare” Panel preparation Shoot X ray X ray sensor in panel would trigger panel to start image acquisition. Wait for image uploaded 4.1.2.3. Timing Setting To set a clear scenario for program, see diagram below for details Workstation 1 5 Panel X Ray Generator 3 X ray 4 2 1. Workstation receives “prep” request. 2. X ray generator is ready for X ray shooting and begins to release X ray. 3.
SKR 4000 DIRECT DIGITIZER User Manual 4.1.3. Freesync Mode 4.1.3.1. Block Diagram Workstation is a host PC device installed with iDetector and SDK. Chapter 3 has described how to establish connection between panel and Workstation. In FreeSync mode, User doesn’t interact with Workstation. After shooting, images would be shown on screen immediately. 4.1.3.2.
Operation 4.1.3.3. Timing Setting 1. X ray generator is ready for X ray shooting and begins to release X ray. 2. Workstation receives “Exposure Prohibited” from Panel. 3. Panel starts uploading Pre-dark image and Light image to Workstation for preview. If hardware offset is selected, panel would do offset first, and then upload preview image (2X2 binning). 4. Panel starts uploading Post-dark image to Workstation.
SKR 4000 DIRECT DIGITIZER User Manual Note: 1. once changing connection from different network card, user must re-connect panel with different IP address. 2. The rule of Multi-Share control is based on IP address. The second terminal with different IP address is not allowed to operate panel after the first one connected. If there is no command transmission between panel and Workstation over 5 minutes, panel releases access authority. 4.3.
Operation Calibrate module related setting, such as making correction and calibration template, template in panel could be uploaded to workstation, and template in workstation could also be downloaded to panel. Local File module related setting, such as import Raw or DCM image. 4.4.
SKR 4000 DIRECT DIGITIZER User Manual Select “Calibrate” Click “Start Templates” Generate Click “Create Offset” Click “Start create offset template file” It will show ”Offset Map Generating” 56 ..................................................................................................................................................KONICA MINOLTA, INC.
Operation After “generating”, it would show “Offset MAP Genetated” 4.4.2. Gain Calibration Template Generation Before Gain template generating, make sure SID1.2m, no copper is required, the GUI of the software maybe different with the below figures. On Gain template generating page, there are five images that need to be got Click “start” button Click “PREP”, exposure and start KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….…………….………..
SKR 4000 DIRECT DIGITIZER User Manual After exposure, click “Acquire” to get the light image If the value meet the expected value, click “Accept”, then get the other four images. If the value does not meet the expected value, please do not click the “Accept”, and adjust the exposure dose ,then click the “PREP” to get light image again After getting five images, click “Generate” to generate gain template Notes: 1 please use software post offset correction. 4.4.3.
Operation On the “Defect Calibration” page, start exposure, there are 8 images need to be captured. Click “Start” button Click “PREP”, exposure and start After exposure, click “Acquire” to get the light image KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….…………….………..
SKR 4000 DIRECT DIGITIZER User Manual If the value meet the expected value, click “Accept”, then get the other 7 images. If the value does not meet the expected value, please do not click the “Accept”, and adjust the exposure dose ,then click the “PREP” to get light image again After getting 8 images, click “Generate” to generate gain template Note: 1 please use software post offset mode. 2.
Operation Workstation, images would be shown on screen 4.5.2. Panel Image Upload Make sure firewall is closed Panel Image is uploaded as following.
SKR 4000 DIRECT DIGITIZER User Manual 4.6.1. Defect Template Check Click “LoadFile” “LocalFile” page on Choose the specified defect template, and click “Open” The defect template showed on the UI 62 will ..................................................................................................................................................KONICA MINOLTA, INC.
Operation 4.6.2. Defect Template Modification Open the template specified defect The defect management dialog box will be showed Find the pixel that needs to be managed, type the coordinate of the pixel and click “Add”, the information will be added to the template If click “Delete”, the information will be deleted Click “Save” KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….…………….………..
SKR 4000 DIRECT DIGITIZER User Manual It is similar to manage the defect pixel, If user need to add the defect line, type the coordinate of the line and click “Add” If the information needs to be deleted, click “Delete” 4.7. Correction and Calibration Management 4.7.1. Correction and Calibration template synchronization Panel supports correction and calibration template storage. So template in panel could be uploaded to Workstation, and template in Workstation could also be downloaded to panel.
Operation Click “Read Status” If the activity shows disenable, please select the one and click “Active” to enable it 4.7.2. Correction and Calibration management Panel supports two ways to do correction and calibration. Software Correction and Calibration defines the scenario that Workstation completes all correction and calibration. If panel complete all correction and calibration by itself, it is named as Hardware Correction and Calibration.
SKR 4000 DIRECT DIGITIZER User Manual Choose “HWPostOffset”, “HWGain”, “HWDefect”, the hardware-based calibration is on If the detector is set as the PrepMode and Acq2, the Offset should be set as HWPreOffset Choose “SWPostOffset”, “SWGain”, “SWDefect”, the software-based calibration is on If the detector is set as the PrepMode and Acq2, the Offset should be set as HWPreOffset 4.8.
Operation User name: admin Password: iray Click “login” Click “ ” Click “Upgrade” Click “Browse” KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….…………….………..
SKR 4000 DIRECT DIGITIZER User Manual Find the MCU file, select it and open it The selected file name will be displayed on the interface. Click “Upgrade” Click “close” There will show the progress bar. If upgrade success, the interface as shown in the picture on the right will be displayed. Otherwise, it means failure. 68 ..................................................................................................................................................KONICA MINOLTA, INC.
Operation 4.8.2. FPGA Update Connect the panel to PC / Open a browser, and type “192.168.8.8” in the search bar, then click the “Enter” button User name: admin Password: iray Click “login” Click “ ” Click “Upgrade” KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….…………….………..
SKR 4000 DIRECT DIGITIZER User Manual Click “Browse” Find the FPGA file, select it and open it The selected file name will be displayed on the interface. Click “Upgrade” Click “close” There will show the progress bar. 70 ..................................................................................................................................................KONICA MINOLTA, INC.
Operation If upgrade success, the interface as shown in the picture on the right will be displayed. Otherwise, it means failure. 4.8.3. ARM Update Connect the panel to PC / Open a browser, and type “192.168.8.8” in the search bar, then click the “Enter” button User name: admin Password: iray Click “login” KONICA MINOLTA, INC..………….…………………………………………………………………………………………………… ….…………….………..
SKR 4000 DIRECT DIGITIZER User Manual Click “ ” Click “Upgrade” Click “Browse” Find the ARM file, select it and open it The selected file name will be displayed on the interface. Click “Upgrade” 72 ..................................................................................................................................................KONICA MINOLTA, INC.
Operation Click “close” There will show the progress bar. If upgrade success, the interface as shown in the picture on the right will be displayed. Otherwise, it means failure. 4.8.4. ALL FIRMWARE Update All of the firmware (MCU, FPGA, and ARM) can be upgraded at the same time, if the file selected is like “Mars1417V3TIS_IMAGE_41_ALL_2019_04_15.ifm”. And the upgrade steps please refer the steps above. 4.9.
SKR 4000 DIRECT DIGITIZER User Manual 4.10. Software 4.10.1. Main GUI KONICA provides test tools, such as iDetector for testing the basic performance of detector. It can connect the detector, acquire image, image correct and calibrate.
Operation 4.10.2. Message Box 4.10.2.1. Status Box Status box defines the current status of panel. SN Serial Number of the detector Status Status of the detector, busy or ready Task The current task being executed Message Information Remaining power of the battery, showed as percentage 4.10.2.2. Progress Bar Progress Bar defines as following. If progress bar is Green when shooting X ray, image quality is acceptable, otherwise image quality would degrade. KONICA MINOLTA, INC..………….
SKR 4000 DIRECT DIGITIZER User Manual 4.10.3. Configuration GUI 4.10.3.1. General Settings Except the following parameters, the value should not be modified for other parameters.
Operation Prep CapMode Reserved Yes Self CapEnable Reserved YES Self Cap Span Time Should not be modified, and keep the original value YES Trigger Mode Trigger mode YES Sequence Interval Time Should not be modified, and keep the original value YES Set Delay Time Exposure window for Freesync mode YES Exp Window Time Exposure Window for Software/Inner mode, the value YES should not be large than 10s Acquire Delay Time Reserved YES Integrate Time Should not be modified, and keep the or
SKR 4000 DIRECT DIGITIZER User Manual 4.10.3.2.
Operation 4.10.3.3.
Regulatory Information 5. Regulatory Information 5.1.
Regulatory Information 009/(R)2012+A2:2010/(R)2012 MOD) CAN/CSA-C22.2 Medical electrical equipment – Part 1: General requirements for basic safety and essential performance No.60601-1:14 ISO 15223-1:2016/ 15223-1:2016 EN ISO Medical devices—Symbols to be used with medical device labels, labeling and information to be supplied—Part 1: General requirements 5.2.
SKR 4000 DIRECT DIGITIZER User Manual 450 430-470 FM, ±5kHz deviation, 1kHz sine, 28V/m 704-787 Pulse modulation 217Hz, 9V/m 800-960 Pulse modulation 18Hz, 28V/m 1700-1990 Pulse modulation 217Hz, 28V/m 2400-2570 Pulse modulation 217Hz, 28V/m 5100-5800 Pulse modulation 217Hz, 9V/m 710 745 780 810 870 930 1720 1845 1970 2450 5240 5500 5785 Input AC power Port Basic EMC standard Phenomenon Electrical transients/burst fast Surges Line-to-line Surges Line-to-ground IEC 61000-4-4 Immunity test
Regulatory Information Electrical transients/burst fast ±2 kV IEC 61000-4-4 100kHz repetition frequency 3V, 0.15MHz-80MHz Conducted disturbances by RF fields induced 6V in ISM bands between 0.
SKR 4000 DIRECT DIGITIZER User Manual The use of accessories, transmitters and cables other than those specified by this User Manual, with the exception of accessories and cables sold by KONICA of SKR 4000 as replacement parts for inner components, may result in increased emission or decreased immunity. 5.3. Radio Frequency Compliance Information Country Item FCC Part 15.107 Sub part (b) / 15.109(g) Sub part B U.S.A FCC Part 15 Sub part E 15.407 FCC Part 15 Sub part C 15.247 Draft ETSI EN 301 489-1V2.
Regulatory Information The panel generates, uses, and radiates radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
SKR 4000 DIRECT DIGITIZER User Manual 6. Trouble Shooting Please refer to service manual. If the problem persists, turn off the panel and contact KNOICA service department. We would provide the best service. 86 ..................................................................................................................................................KONICA MINOLTA, INC.
Information Service Service Information 7. 7.1. Product Lifetime The estimated product lifetime is up to 7 years under appropriate regular inspection and maintenance (battery 5 years). 7.2. Regular Inspection and Maintenance In order to ensure the safety of patients and operator, to maintain the performance and reliability of the panel, be sure to perform regular inspection at least once a year. If necessary, clean up the panel, make adjustments or replace consumables such as fuses etc.
SKR 4000 DIRECT DIGITIZER User Manual Appendix A Information of Manufactures Company: KONICA MINOLTA, INC. ADDRESS: 1 Sakura-machi, Hino-shi, Tokyo, 191-8511, Japan 88 ..................................................................................................................................................KONICA MINOLTA, INC.
Information Service FCC Regulations: Contains module’s FCC ID:2ACHK-01070189 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
SKR 4000 DIRECT DIGITIZER User Manual This is because the device is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless Base station antenna, the lower the power output. The exposure standard for wireless devices employing a unit of measurement is known as the Specific Absorption Rate, or SAR. The SAR limit recommended by the ICNIRP used by the general public is 2.