Wireless Digital Flat Panel Detector Mars1717V User Manual Document Version: A0 Document ID: 092-201-02 Release Date: 2019.05.27 Before operating, please read this user manual and pay attention to all safety precautions. Please ensure that this user's manual is properly maintained so that it can be accessed at any time ( reserve ). Please use it correctly on the basis of full understanding of the content.
To Customers Congratulations on your purchase of the Fixed Digital Flat Panel (hereinafter referred to as Mars1717V) which is manufactured by iRay Technology Co.Ltd. (Hereinafter referred to as iRay). At iRay, we strive to not only make the world-class products that deliver the best value possible to our customers but also offer the highest quality of service and customer care. Please take time to read through this user guide in order to utilize the product effectively.
Mars1717V Digital Flat Panel Detector User Manual Caring for your environment This symbol indicates that this product is not to be disposed of with your residential or commercial waste. Recycling iRay Equipment Please do not dispose of this product with your residential or commercial waste. Improper handling of this type of waste could have a negative impact on health and on the environment.
To Customers Symbols and Conventions The following symbols and conventions are used throughout the user guide. This symbol is used to identify conditions under which improper use of the product may cause death or serious personal injury. This notice is used to identify conditions under which improper use of the product may cause minor personal injury. This notice is used to identify conditions under which improper use of the product may cause property damage.
Mars1717V Digital Flat Panel Detector User Manual Labels and markings on the equipment The contents of the labels and markings on iRay Mar1717V product are indicated below: Symbol Guide Caution: please refer to the instructions in the user manual. This symbol is used to indicate that the equipment has passed CE testing and it is followed by the CE number. This symbol is used to identify the manufactuer's series number which is after, below or adjacent to the symbol.
To Customers Handled with care. This symbol is used to indicate the operational temperature limits. This symbol is used to indicate the storage temperature limits. Package symbol, fragile. Package symbol, keep away from sunlight. Package symbol, keep dry. Package symbol, this symbol is used to indicate the humidity limits. Package symbol, keep the equipment up right. Package symbol, do not roll the transportation package. Package symbol, this symbol is used to indicate stacking limit number.
Mars1717V Digital Flat Panel Detector User Manual Contents TO CUSTOMERS....................................................................................................................................... 1 CONTENTS................................................................................................................................................ 6 1. SAFETY.........................................................................................................................................
To Customers 8. SERVICE INFORMATION..................................................................................................................97 8.1 Service Office Info............................................................................................................................98 8.2 Product Lifetime................................................................................................................................98 8.3 Regular Inspection and Maintenance....................
Mars1717V Digital Flat Panel Detector User Manual 1. Safety 1.1 Safety precautions..............................................................................................................................9 1.2 Notes for Using................................................................................................................................14 8 iRay Technology Co. Ltd.
1. Safety 1.1 Safety precautions Follow these safeguards and properly use the equipment to prevent injury and damage to any equipment/data. WARNING Installation and environment of Do not use or store the equipment near flammable chemicals such as alcohol, thinner, benzene, etc. If chemicals are spilled or evaporate, it may result in fire or electric shock through contact with electric parts inside the equipment. Also, some disinfectants are flammable. Be sure to take care when using them.
Mars1717V Digital Flat Panel Detector User Manual resulting in fire or electric shock. WARNING Handling Never disassemble or modify the equipment. No modification of this equipment is allowed. Parts of the Mar1717V that are not serviced or maintained while in use with the patient. Doing so may result in fire or electric shock. Also, since the equipment incorporates parts that may cause electric shock as well as other hazardous parts, touching them may cause death or serious injury.
1. Safety Clean the plug of the power cord periodically by unplugging it from the AC outlet and removing dust or dirt from the plug, its periphery and AC outlet with a dry cloth. If the cord is kept plugged in for a long time in a dusty, humid or sooty place, dust around the plug will attract moisture; this could cause insulation failure that may result in a fire. For safety reasons, be sure to turn OFF the power to each piece of equipment when performing inspections indicated in this manual.
Mars1717V Digital Flat Panel Detector User Manual Handling Do not spill liquid or chemicals onto the equipment. In case the patient is injured, it is not allowed to contact with blood or other body fluids. Doing so may result in fire or electric shock. In such a situation, protect the equipment with a disposable cover as necessary. Turn OFF the power and pull out the plug to each piece of equipment for safety when not used. CAUTION Handling Handle the equipment carefully.
1. Safety Be sure to use the equipment on a protected foam. Otherwise, the internal image sensor may be damaged. Be sure to securely hold the detector while using it in upright positions. Otherwise, the detector may fall over, resulting in injury to the user or patient, or may flip over, resulting in damage to the inner device. Keep the same load (same pressure) on the detector when acquiring the image. Otherwise, the image will be incorrect. CAUTION iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual 1.2 Notes for Using When using the equipment, take the following precautions. Otherwise, problems may occur and the equipment may not function correctly. Before exposure Be sure to check the equipment daily and confirm that it works properly. Be sure there be a battery installing on the Mars1717V to avoid the power off suddenly Sudden heating of the room in cold areas will cause condensation to form on the equipment.
Mars1717V Digital Flat Panel Detector User Manual 2. General Description 2.1 Scope................................................................................................................................................. 16 2.2 Model..................................................................................................................................................16 2.3 Characteristic........................................................................................................
2. General Description Mars1717V ( configuration : Mars1717V3, hereinafter referred as Mars1717V ) is a cassette-size wireless X-ray flat panel detector based on amorphous silicon thin-film transistor technologies. It is developed to provide the good quality of radiographic image, which contains an active matrix of 3072×3072 with 139um pixel pitch. Panels’ scitinator is CsI (Cesium Iodide). Mars1717V supports wireless communication between panel and Workstation, and can be used as a real portable panel.
2. General Description 2.3 Characteristic Wireless static flat panel detector used for general radiography. Cassette-size Sync-shot exposure trigger CsI scintillation screen. Easy to upgrade firmware. Battery recycling 16-bit AD 2.4 INTENDED USE Mars1717V Wireless Digital Flat Panel Detector is indicated for digital imaging solution designed for providing general radiographic diagnosis of human anatomy.
Mars1717V Digital Flat Panel Detector User Manual Weight: not relevant Health: not relevant Nationality: multiple Gender: except for pregnant women Intended OPERATOR: All of use, maintenance and operation steps should be carried out by the operator who has accepted the professional training offered by the company's customer service staff. Life-time: Life-time: 5 years without frequency limit 2.
2. General Description 2.8 Product Components Mars1717V comes with both DC power supply and battery package. Once powered on, it would build a connection with Workstation through Ethernet cable (only for service) or Wireless connection. Item Mars1717V Detector Medical Adapter for Detector and Battery Charger Description 1pcs Main Unit 1 pcs DC 24V 2 pcs Battery iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual Ethernet Cable 1pcs (Only for service) 3.5 m Gigabit Ethernet Cable AC Power Cable DC Power Cable Battery Charger 20 1pcs 3m 1 pcs 1 pcs 3.5 m 1pcs iRay Technology Co. Ltd..
2. General Description CD-Rom iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual 2.9 Components Description and Specification 2.9.1 Detector ExternalSignals Input Control Panels Item 22 Name Description iRay Technology Co. Ltd..
2. General Description A DC Jack 24V DC input B Mode Key Change the work mode of Panel, refer to 3.1.5 C Detector Indicator Detector indicator of control panel D Power Button Power button of control panel F Antenna Antenna H Maintenance Cover For service engineer to maintenance I Battery Lock The lock button for detaching battery J Detector Label Product information.
Mars1717V Digital Flat Panel Detector User Manual 14dBm (Typ.) @802.11g 13dBm (Typ.) @802.11n HT20 11dBm (Typ.) @802.11n HT40 16dBm@2.4GHz 13dBm@5.8GHz Wireless Modulation Wireless Band 11b: DSSS (DBPSK, DQPSK and CCK) 11a/g/n: OFDM (BPSK, QPSK,16QAM, 64QAM) 2.4GHz≤40MHz 5.19GHz≤40MHz 5.8GHz≤40MHz X-ray Energy 24 40kV to 150kV iRay Technology Co. Ltd..
2. General Description 2.9.2 Battery Item Name Description A Battery Label / B Battery Interface 8 Pin Battery connector C Pilot Pin / D Indicator Installation direction indicator iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual Dimension and Specification Item Model Specifications Battery-KV Rated Capacity Min. 3950mAh, Typ. 4180mAh @ Discharge 0.2C Nominal Voltage 10.8V Charge Voltage 12.6±0.05V Discharged End Voltage 8.25V Charging Method CC-CV Operating Temperature Charge 0℃-+45℃, Discharge-10℃-+40℃ 1 month-20℃-+50℃ Storage Temperature 3 month -20℃-+40℃ 6 month -20℃-+20℃ 26 iRay Technology Co. Ltd..
2. General Description Relative Humidity Dimension (L × W × H) Weight iRay Technology Co. Ltd. 65±20% 210 x 115 x 7.5 mm 0.
Mars1717V Digital Flat Panel Detector User Manual 2.9.3 Battery Charger Item Name Description A Battery Interface 8 Pin Battery connector B Capacity Indicator The indicator definition is as follow C Power Indicator The indicator definition is as follow D Hand Pull Position / E The limit ball plug / F DC Jack 24V DC input Dimension and Specification 28 iRay Technology Co. Ltd..
2. General Description Item Model iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual Simultaneous Charging Full charging time 2.5 hours Rated power supply 24V(DC) Dimension (L × W × H) Weight 30 2 battery packs 300 x 263 x 42 mm 1.26 kg iRay Technology Co. Ltd..
2. General Description Firmware versions definition Firmware minor versions Firmware major versions Power indicator Firmware versions Lighting Status Value range (BCD) Major 00-11 Minor 0000-1111 Power indicator definition: Power Indicator Lighting Status Operating Status OFF No external DC adaptor input GREEN External DC adaptor input The battery charging capacity indicator definition: X Group Indicator I, II and III grid off iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual I grid blinking Battery Insert with capacity ≤30%,charging II and III grid off Battery Insert with capacity >30% and II grid blinking ≤60%,charging I and III grid off Battery Insert with capacity >60% and III grid blinking ≤95%,charging I and II grid off Battery Insert with capacity >95% and I and II grid off charging, when capacity = 100%, III grid on charging stops Battery enter into 2nd level protection, I, II and III blinking automatic
2. General Description 2.9.6 Use Environment Temperature Temperature change Humidity Atmospheric Pressure Operating 5~30℃ <1k/min 30%~75% RH 700~1060hPa Storage -10~40℃ <1k/min 10%~90% RH 700~1060hPa Pressure Change <10kp/min (1kp=1.0197E-5Pa) <10kp/min (1kp=1.0197E-5Pa) The Mars1717V serial detectors shall operate at an altitude specified not more than 3000m, the environment is only for detector. iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual 3. Installation 3.1 Panel Installation...........................................................................................................................35 3.1.1 Attach Battery Pack............................................................................................................... 35 3.1.2 Attach DC Power....................................................................................................................36 3.1.
3. Installation 3.1 Panel Installation 3.1.1 Attach Battery Pack Mars1717V can be powered by both battery package and DC power. Once battery package is inserted or DC power is on, Panel would be activated immediately. If none of battery and DC power is on, Mars1717V would power off. Please see below for battery installation. Make sure that the connectors on the battery package are pointed to the cave in battery compartment.
Mars1717V Digital Flat Panel Detector User Manual 3.1.2 Attach DC Power Please see below for DC power installation. Connect one end of DC Power Cable to the Medical Adapter As figure is power interface Ethernet interface Connect another end of DC Power Cable to the DC input of the detector. 3.1.3 Booting Up On the control panel, user can press power button to power on/off.
3. Installation After booting up, users can check the status indication of LED as follows.
Mars1717V Digital Flat Panel Detector User Manual Mode Indicator Lighting Status Description Power OFF Wired Connection(Service only) Green ON AP Mode Connection is built Blue ON Client Mode connection is built OFF Status indicator is as table: Status Indicator Lighting Status Description Panel Power OFF Exposure Prohibited Green ON Exposure Enable Orange ON Fatal Error Orange blinking Safety Mode OFF 38 iRay Technology Co. Ltd..
3. Installation 3.1.5 Button function table The Button function is shown as table below Power Action N.A. Mode FPD Note Status / Power ON No-Action No-Action Short-Hold No-Action Hold for 4 seconds. Power Forced Restart OFF Hold for more than 7 seconds, Long-Hold No-Action Release Power Key when the POWER indicator is ON. Hold for more than 7 seconds, when the Forced Restart Long-Hold No-Action POWER indicator is OFF and then ON, Release Power Key.
Mars1717V Digital Flat Panel Detector User Manual 3.2 Battery Charger Installation Operation Figure Unload Battery from battery charger. Insert battery into battery charger. Note the interface position as figure. Press the battery to the bottom of battery compartment. 40 iRay Technology Co. Ltd..
Mars1717V Digital Flat Panel Detector User Manual 4. Software Setup 4.1 SYSTEM REQUIREMENT...........................................................................................................42 Environment setup......................................................................................................................... 42 Connetion Mode.............................................................................................................................
Mars1717V Digital Flat Panel Detector User Manual 4.1 System requirement iDetector is developed and deployed on Windows Operation System, it can be run on Windows XP/Windows 7/Windows 8/Windows 10, OS should install latest service pack. And requires computer memory 4 GB minimum. Firewall should be shut down to avoid commuication issue. 4.2 Environment setup Setup files and download url are included in Software Development Kit(hereafter refers as SDK) directory: Tools\env_setup. 1.
4. Software Setup 4.4 Wired Connection Setup (Service Only) Select wired network adapter that connected to the detector. Right click the network adapter. Then select properties. iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual Double click IPV4 item Default IP settings: IP address: 192.168.8.188 Subnet mask: 255.255.255.0 The IP address should be identical with Cfg_HostIP item in work_dir\Mar1717V3 \config.ini file. 4.5 Wireless AP Mode Connection To complete wireless connection configuration, user has to finish actions listed below. 44 iRay Technology Co. Ltd..
4. Software Setup 4.5.1 Get Start with Default AP setting The Mars1717V detector alows user to get start with Default AP setting User could config the panel with default setting as follows Set the Panel to AP mode, as the 3.1.5 Mode key discription Setup the Workstation IP address Open local network management interface Right click the wireless adapter, select properties and entered the Wireless Connetion Properties window as shown left. Double click IPV4 item iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual Set the wireless adaptor IP as follows IP address: 192.168.8.188 Subnet mask: 255.255.255.0 Click OK to confirm the settings Open local wireless signal list Select SSID which named as “FPD-detector SN”. Input Default Password “12345678” and connect the Panel AP. 46 iRay Technology Co. Ltd..
4. Software Setup Select SSID which belongs to detectors; Input password and log into system Open SDK and choose product start connection After logging in the detector, User can Custom AP setting or Set the Wireless Client Mode 4.5.2 Configuration of detector Wired cable can be used to configure panel wireless AP mode. The wired connection should be used by the service operator only. To start wired cable configuration, users should finish 4.4, then proceed to the steps below.
Mars1717V Digital Flat Panel Detector User Manual Click “Detector” Select “wifi” Choose AP mode 48 iRay Technology Co. Ltd..
4. Software Setup Click “Read Config” to get default setting. Change SSID and password setting. make sure SSID is different from other already exist; Change channels and frequency setting Click ”Channel” and choose a clean frequency and channel iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual Click ”write config” Do not remove wired cable until FPD status from Busy become “Ready” 50 iRay Technology Co. Ltd..
4. Software Setup Configuration of external wireless card Open local wireless signal list Select SSID which belongs to detectors; Input password and log into system iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual Open wireless card configuration open IPV4 setting IP setting as follows IP address: 192.168.8.188 IP address: Subnet mask: 255.255.255.0 192.168.8.188 52 iRay Technology Co. Ltd..
4. Software Setup Subnet mask: 255.255.255.0 Open SDK and choose product start connection iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual 4.6 Wireless Client Mode Conneciton 1. Setup physical connection Connect one end of Gigabit Ethernet Cable to Workstation, Connect another end to LAN port of External wireless AP refer to 4.4 and 4.5 2. AP setup Set up the Wireless AP to: IP address 192.168.8.1 Subnet Mask 255.255.255.
4. Software Setup Right click the network adapter, select properties and entered the Local connetion Properties window as shown left. Double click IPV4 item Select “Obtain an IP address automatically” iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual Open browser and type 192.168.1.1 Log into external wireless AP Wireless setup SSID: NETGEAR_BIG_24 Configure 2.
4. Software Setup LAN setup Configure LAN IP address IP address: 192.168.8.1 Subnet Mask: 255.255.255.0 The AP setup is done 3. Workstation IP setup After AP setup done, the user can setup the Workstation IP address Open local network management interface iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual Right click the network adapter, select properties and entered the Local connetion Properties window as shown left. Double click IPV4 item Set the Default IP as follows: IP address: 192.168.8.188 Subnet mask: 255.255.255.0 58 iRay Technology Co. Ltd..
4. Software Setup The IP address should be identical with Cfg_HostIP item in work_dir\Mars1717V3\co nfig.ini file. 4. Panel setup Either Wired Cable or AP mode can be used to configure detector To start configuration with wired cable. It is necessary to finish 4.4, then proceed to the steps below. To start configuration with AP. It is necessary to finish 4.5, then proceed to the steps below. iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual Connect panel to Workstation like 4.4 or 4.5 Click “Detector” Click “Read Config” Choose Client mode Click “Add” Type SSID and Password Click “Apply” 60 iRay Technology Co. Ltd..
4. Software Setup Choose SSID and select(There will be √ occurred) Click “write config” to save parameters. Turn on wireless router. Make sure there are wired connection between router and work station and IP 192.168.8.188. Click “Read wifi Status” to check wireless transmission status, numerical value occurred means the link is up and available. Since we have chosen default SSID and password, it would connect to wireless AP immediately after powered on next time. iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual 4.7 iDetector software SDK supply iDetector as tool softwore: 32-bits iDetector.exe: Tools\iDetector\w32 64-bits iDetector.exe: Tools\iDetector\x64 Double click iDetector.exe to run the software. For different software version, the UI maybe have little difference. If change, forgive us for not issuing a separate notice. Users can refer to 903-341-14_iDetector_UserManual_EN_A4 for specific operation methods.
4. Software Setup 4.7.1 HomePage The main function in this page is to connect detector. C B A A Item Function description Name Display the name of detector SN Display the SN of detector Product Type Display the type of detector State Display the connection state (Bind,Unknown, Ready etc.) B Button Function description Connect Click this button to connect the selected detector. Close Click this button to disconnect the selected detector.
Mars1717V Digital Flat Panel Detector User Manual 4.7.2 Acquire Page This page is used to acquire image under different work mode, and user can choose correction mode too. When acquire image finished there will be a preview image shown on the screen.The propertities of image is displayed on the left of preview image. On the right of preview image there is a list to show thumbnail of images. User can select it and double click to see for detail. User can rotate, reverse or mirror image.
4. Software Setup Functions in this Page. Correction Menu Description HW- Dohardware PostOffset correction for image if PostOffset checked(Only for Mars detector) Gain HWGain Do hardware Gain correction for image if selected Defect HWDefect Do hardware defect correction for image if Offset checked(for Mars and Mercu detector) Acqurie Button Description Prep Clear. Prepare to integrate.
Mars1717V Digital Flat Panel Detector User Manual several ROI area. WW/WL Auto adjust WW/WL based on selected area by right button of mouse. Image List Show thumbnails 4.7.3 Detector Page In Detector page, Detector Parameters, Sensor, Wifi and Images tab could be set. Please refer to 903-341-14_iDetector_UserManual_EN_A4, for specific operation guide. 4.7.4 Calibrate Page Offset, Gain, Defect calibrate files can be generated and managed in this page.
4. Software Setup 4.8 List of the HAZARDOUS SITUATIONS resulting from a failure of the IT-NETWORK a) The operating system is not compatibility; b) Change or upgrade the software failed; c) The compatibility of the interface; d) The data transfer protocol error; e) The inconsistent of interface or format leads to data distortion; f) The data output failed; iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual 5. Operation 5.1 MAIN OPERATION............................................................................................................................69 5.1.1 Steps for acquiring image...................................................................................................70 5.1.2 Software Mode........................................................................................................................71 5.1.3 Inner Mode............
5. Operation Mars1717V provides SDK for user to integrate panel into their DR system. Additionally, it also provides an application for demonstration, i.e. iDetector. User can use iDetector to control panel without DR system. 5.1 Main Operation To Acquire X-ray image is the main operation of Mars1717V. Most importantly, panel should build synchronization with X-ray generator.Mars1717V is born with four ways to acquire X-ray image that is Software Mode, Inner Mode, Prep Mode and FreeSync Mode.
Mars1717V Digital Flat Panel Detector User Manual 5.1.1 Steps for acquiring image Make sure the hardware is connected correctly and then power on.
5. Operation 5.1.2 Software Mode 5.1.2.1 Block Diagram Software mode is the basic way to acquire x-ray image. Please see figure below for general feature Workstation is a host device installed with iDetector and SDK. Chapter 3 has described how to establish connection between panels and workstation. In software mode, workstation does not control x-ray generator. Users would decide when to shoot x-ray. iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual 5.1.2.2 Work flow Click “Prep” Panel preparation, Wait until the warning message change from “Exposure Prohibit” to “Exposure Enable” Shoot X-ray at any time. However the longer time you wait. The worse image would be. So please shoot once X-ray generator is ready. After shooting, Click”Acquire” Wait for image uploaded 5.1.2.3 Timing Setting To set a clear scenario for programming, see diagram below for details 1.
5. Operation 3. Panel finishes “Clear” and send a message to workstation “Exposure Enable”. 4. Workstation shows “Exposure Enable” on the IDetector’s message bar to tell user shoot X-ray now. 5. User triggers X-ray generator to initialize and do anode rotation to prepare for X-ray shooting. 6. X-ray generator finishes preparation for X-ray shooting and reminds user to shoot. 7. X-ray generator starts releasing X-ray. 8. X-ray generator finishes x-ray shooting. 9.
Mars1717V Digital Flat Panel Detector User Manual 5.1.3 Inner Mode 5.1.3.1 Block Diagram Workstation is a host PC device installed with IDetector and SDK. Chapter 3 has described how to establish connection between panels and workstation. In inner mode, workstation does not control X-ray generator. Users would decide when to shoot X-ray. 5.1.3.2 Work Flow Click “Prepare” Panel preparation, Wait until the warning message change from “Exposure Prohibit” to “Exposure Enable” Shoot X-ray in exposure window.
5. Operation 5.1.3.3 Timing Setting To set a clear scenario for program, see diagram below for details 1. Workstation receives “prep” request and sends “Clear” to panels. 2. Panel receives “clear” from Workstation, start clear operation. Meanwhile, panel would send “Exposure Prohibited” to Workstation. 3. Panel finishes”Clear” operation and send “Exposure Enable” to Workstation. 4. Workstation shows “Exposure Enable” on the iDetector’s message bar to tell user shoot X-ray. 5.
Mars1717V Digital Flat Panel Detector User Manual 12. Workstation receives all image data from panel which are after calibration is Hardware calibration is on. If Hardware Pre-offset and Hardware calibration is selected, image got is the final image. If Hardware Post offset and Hardware calibration is selected, image got from detector would be preview image. After step12, Detector would do another dark image acquisition. With both light image and dark image, detector completes all the correction process.
5. Operation 5.1.4 FreeSync Mode 5.1.4.1 Block Diagram Workstation is a host PC device installed with iDetector and SDK. Chapter 3 has described how to establish connection between panel and Workstation. In FreeSync mode, User doesn’t interact with Workstation. After shooting, images would be shown on screen immediately. 5.1.4.
Mars1717V Digital Flat Panel Detector User Manual 5.1.4.3 Timing Setting 1. X-ray generator is ready for X-ray shooting and begins to release X-ray. 2. Workstation receives “Exposure Prohibited” from Panel. 3. If hardware offset is selected, panel would do offset first, and then upload preview image. 4. If hardware offset is chosen, panel would do correction and calibration first, then upload processed image to Workstation. 5. Workstation receives “Exposure Enable” from Panel. 5.1.
5. Operation 5.2 Correction and Calibration Template Generation The correction and calibration should be performed after installation and it is recommended to perform the new correction and calibration after any major change on the system settings and hardware configuration. On the other hand, it is also recommended to do the correction and calibration in each 6 months. 5.2.
Mars1717V Digital Flat Panel Detector User Manual 5.2.2 Gain Calibration Template Generation If the relative position between tube and detector changed or KV value changed, it suggest to create gain template file. Enter Create Gain page Click "Start" button to start process. Click PREP button, acquire image. Please exposure after Acquire button enable. And click Acquire button to acquire image after exposure end. Click Accept button after acquired image.
5. Operation Create gain template need several images. You can click Generate button to generate Gain template once one image was captured. But it may lead to imperfect template quanlity. Download template file dialog will pop up if "Download to FPD after generation" option was checked. Click Download button to download the template into the detector. Select Mode&Files tab. Click Read Status button to check whether just downloaded gain template is enable.
Mars1717V Digital Flat Panel Detector User Manual Create Defect tab. Click "Start" button to start process. Click PREP button, acquire image. Please exposure after Acquire button enable. And click Acquire button to acquire image after exposure end. Click Accept button after acquired image. If Current Value textbox is yellow , click PREP button. Re-acquire images after adjust generator parameters. Note: In different trigger mode, the operation maybe have little difference.
5. Operation Download template file dialog will pop up if "Download to FPD after generation" option was checked. Click Download button to download the template into the detector. Select Mode&Files tab. Click Read Status button to check whether just downloaded gain template is enable. If not, please click Active button to enable. 5.3 Local Image Check “OPEN” provides two features for image check and uploading. Local Image Check, Panel Image Upload.
Mars1717V Digital Flat Panel Detector User Manual Click “Local File” button in “Local File” UI, choose the specified file In this page user can open the image files saved in local, the file formate can be raw, tiff, dft. When the software is disconnected to detector, the file still can be opened. Click “Load File”, there will be an open file wizard. Select file and click open or double click the file. The tiff file will be opened directly.
5. Operation Value Value of the current cursor at the point Width Image width Height Image height Rotate the image clockwise, 90 degrees every time. Rotate the image anticlockwise, 90 degrees every time. Mirror Open or close mirror ROI ROI tool , to view the image of the AVG, SV, SNR and other parameters. Press "ctrl" key, can create several ROI area. WW/WL Auto adjust WW/WL based on selected area by right button of mouse. 5.
Mars1717V Digital Flat Panel Detector User Manual The dialog box shows the version of the current firmware Click “Browse” to choose the firmware file to upgrade, the extension of the file is .ifirm After choosing the file, the lower dialog box shows the version of the new firmware, user should check the information and click “Start Upgrade” After the upgrade process is finished, power-cycle the detector Note: 1. There is a progress bar for indication.
Mars1717V Digital Flat Panel Detector User Manual 6. Regulatory Information 6.1 Medical equipment safety standards............................................................................................ 88 6.2 Guidance and manufacture’s declaration for EMC..................................................................90 6.2.1 EMI Compliance Table.......................................................................................................... 90 6.2.2 EMS Compliance Table....................
6. Regulatory Information 6.
Mars1717V Digital Flat Panel Detector User Manual 1:2005/(R)2012+A1:2012+C1:2009/(R)20 requirements for basic safety and essential 12+A2:2010/(R)2012 performance Medical electrical equipment –Part 1: General CAN/CSA-C22.2 No.
6. Regulatory Information Medical devices – Application of usability engineering EN 62366:2008 to medical devices ANSI/AAMI ES60601-1:2005+ Medical Electrical Equipment – Part 1: General Amendment 1:2012+ Amendment 2:2010 requirements for safety and essential performance CAN/CSA C22.2 No.
Mars1717V Digital Flat Panel Detector User Manual 80% AM at 1kHz Near fields from RF IEC 61000-4-3 wireless Refer to table “Near fields from RF wireless communications equipment” communications equipment Rated power IEC 61000-4-8 frequency magnetic 30A/m 50Hz or 60Hz fields Near fields from RF wireless communications equipment Test frequency Band Immunity test levels (MHz) (MHz) Professional healthcare facility environment 385 380-390 Pulse modulation 18Hz, 27V/m 450 430-470 FM, ±5k
6. Regulatory Information standard Electrical fast transients/burst Surges Line-to-line Surges Line-to-ground IEC 61000-4-4 Professional healthcare facility environment ±2 kV 100kHz repetition frequency IEC 61000-4-5 ±0.5 kV, ±1 kV IEC 61000-4-5 ±0.5 kV, ±1 kV, ±2 kV 3V, 0.15MHz-80MHz Conducted disturbances IEC 61000-4-6 induced by RF fields 6V in ISM bands between 0.15MHz and 80MHz 80%AM at 1kHz 0% UT; 0.
Mars1717V Digital Flat Panel Detector User Manual DC Power Cable LAN Cable (configuration mode) 3.5m Unshielded 1 pcs DC Power 3m Shielded 1 pcs Signal Important information regarding Electromagnetic Compatibility (EMC) Mars1717V requires special precautions regarding EMC and needs to be installed only by iRay or authorized personnel and put into service according to EMC information provided in the user manual.
6. Regulatory Information EN 50566:2017 EN 62476:2010 EN 55032:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 6.3.1 FCC Compliance The panel has been tested to comply with limits for a Class B digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to the following two conditions. The panel may not cause harmful interference.
Mars1717V Digital Flat Panel Detector User Manual Standards Description IEC 62133:2012 Secondary cells and batteries containing alkaline or other nonacid electrolytes UN38.3 United Nations Recommendations on the Transport of dangerous goods Manual of tests and Criteria ST/SG/AC.10/11/Rev.5/Amend.1&Amend.2 iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual 7. Trouble Shooting TROUBLE SHOOTING.................................................................................................................. 96 Please refer to service manual. If the problem persists, turn off the panel and contact iRay service department (service@iraygroup.com). We would provide the best service. iRay Technology Co. Ltd.
Mars1717V Digital Flat Panel Detector User Manual 8. Service Information 8.1 Product Lifetime................................................................................................................................98 8.2 Regular Inspection and Maintenance........................................................................................... 98 8.3 Repair................................................................................................................................................
Mars1717V Digital Flat Panel Detector User Manual 8.1 Service Office Info 8.2 Product Lifetime The estimated product lifetime is up to 5 years under appropriate regular inspection and maintenance. 8.3 Regular Inspection and Maintenance In order to ensure the safety of patients and operator, to maintain the performance and reliability of the panel, be sure to perform regular inspection at least once a year. If necessary, clean up the panel, make adjustments or replace consumables such as fuses etc.
Appendix Main parts (parts required to maintain the function of the product) of this product will be stocked for 5 years after discontinuance of production for repairing. iRay Technology Co. Ltd.
8. Service Information Appendix Appendix A Information of Manufactures..........................................................................................101 Appendix B Information of Medical Device Directive European Representative........................101 100 iRay Technology Co. Ltd..
Mars1717V Digital Flat Panel Detector User Manual Appendix A Information of Manufactures Appendix B COMPANY: iRay Technology Taicang Ltd. ADDRESS: No.33 Xinggang Road, Taicang Port Economic and Technological Development Zone, Jiangsu, China ZIP CODE: 215434 TELEPHONE: +86 0512-53690872 FAX: +86 0512-53690872 HOMEPAGE: WWW.IRAYGROUP.
8. Service Information FCC Regulations: Contains FCC ID:2ACHK-01070189 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Appendix limits in IC RSS-102 and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528 and IEC 62209. This equipment should be installed and operated with minimum distance of 0 cm between the radiator and your body. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. Cet appareil est conforme aux Normes RSS d'Industy Canada.
8. Service Information The exposure standard for wireless devices employing a unit of measurement is known as the Specific Absorption Rate, or SAR. The SAR limit recommended by the ICNIRP used by the general public is 2.0W/kg averaged over ten grams of tissue and, is 1,6W/kg Averaged over one gram of tissue by IEEE Std 1528. The FCC has granted an Equipment Authorization for this product with all reported SAR Levels evaluated as in compliance with the FCC RF exposure guidelines.
Appendix l'exposition aux radiofréquences lorsqu'il est testé en contact direct avec le corps. Pour cet appareil, la valeur SAR la plus élevée pour une utilisation près du corps est de 0.182 W/kg. Bien qu'il puisse exister des différences entre les niveaux de SAR selon les dispositifs et les emplacements où ils sont utilisés, tous répondent aux exigences Gouvernementales. La valeur SAR déclarée conforme est une distance de 0 mm entre l'unité et le corps humain.