Wireless Digital Flat Panel Detector Mars1717X User Manual Version A1 Doc ID 053-201-02 Release Date: 2020.08.11 Before operating, please read this user manual and pay attention to all safety precautions. Please ensure that this user manual is properly maintained so that it can be accessed at any time (reserve). Please use it correctly based on full understanding of the content.
To Customers About FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference; (2) This device must accept any interference received, including interference that may cause undesired operation.
Wireless Digital Flat Panel Detector Mars1717X To Customers Congratulations on your purchase of the Fixed Digital Flat Panel (hereinafter referred to as Mars1717X) which is manufactured by iRay Technology Co.Ltd. (Hereinafter referred to as iRay). At iRay, we strive to not only make the world-class products that deliver the best value possible to our customers but also offer the highest quality of service and customer care.
To Customers Caring for your environment This symbol indicates that this product is not to be disposed of with your residential or commercial waste. Recycling iRay Equipment Please do not dispose of this product with your residential or commercial waste. Improper handling of this type of waste could have a negative impact on health and on the environment. Some countries or regions, such as the European Union, have set up systems to collect and recycle electrical or electronic waste items.
Wireless Digital Flat Panel Detector Mars1717X Copyright All rights reserved No part of this publication may be reproduced in any form or by any means without the written permission of iRay. The information contained herein is designed only for use with iRay Mars1717X. Trademarks The iRay name and iRay logo are registered trademarks of iRay Technology Co. Ltd.
To Customers Symbols and Conventions The following symbols and conventions are used throughout the user guide. Identify the conditions under which improper use of the product may cause death or serious personal injury. Identify conditions under which improper use of the product may cause minor personal injury. Identify conditions under which improper use of the product may cause property damage. Indicate a prohibited operation.
Wireless Digital Flat Panel Detector Mars1717X Labels and markings on the equipment Symbol Description Caution: please refer to the instructions in the user manual. Indicates that the equipment has passed CE testing and the CE Notified Body number follows it. Serial number of the product. Name and address of the manufacturer. Expiring date of this product. Name and address of iRay authorized representative in the European region. Consultation of the user guide for general information.
To Customers Handled with care. Operational temperature limits. Storage temperature limits. Fragile Keep away from sunlight Keep dry Humidity limits. Keep the equipment up right. Do not roll the transportation package. Stacking limit number.
Wireless Digital Flat Panel Detector Mars1717X Contents CONTENTS ................................................................................................................................... 8 1. GENERAL DESCRIPTION ................................................................................ 11 1.1. Safety Precautions .................................................................................... 11 1.2. Notes for Use .........................................................................
Contents 6.3. Radio Frequency Compliance Information .............................................. 81 6.4. Battery Safety Standards ........................................................................ 84 6.5. Product Label .......................................................................................... 85 7. TROUBLE SHOOTING ...................................................................................... 89 8. SERVICE INFORMATION ...............................................
Wireless Digital Flat Panel Detector Mars1717X 1. GENERAL DESCRIPTION ................................................................................ 11 1.1. Safety Precautions .................................................................................... 11 1.2. Notes for Use .............................................................................................
1. Safety Information 1. General Description 1.1. Safety Precautions Follow these safeguards and properly use the equipment to prevent injury and damage to any equipment/data WARNING Installation and environment of use Do not use or store the equipment near flammable chemicals such as alcohol, thinner, benzene, etc. If chemicals are spilled or evaporate, it may result in fire or electric shock through contact with electric parts inside the equipment. Also, some disinfectants are flammable.
Wireless Digital Flat Panel Detector Mars1717X Power supply Do not connect a multiple portable socket-outlet or extension cord to the system. Doing so may result in fire or electric shock. To avoid the risk of electric shock, this equipment must only be connected to power supply with protective earth. Not doing so may result in fire or electric shock. Securely plug the power cord into the AC outlet.
1. Safety Information Have the patient take a fixed posture and do not let the patient touch parts unnecessarily. If the patient touches connectors or switches, it may result in electric shock or malfunction of the equipment. When a problem occurs Should any of the following occurs, immediately unplug the power cord of Control Box, and contact your sales representative or local iRay dealer: When there is smoke, an odd smell or abnormal sound.
Wireless Digital Flat Panel Detector Mars1717X CAUTION Installation and environment of use Do not install the equipment in any of the locations listed below. Doing so may result in failure, malfunction, equipment falling, fire or injury.
1. Safety Information Power supply Always connect the three-core power cord plug to a grounded AC power outlet. To make it easy to disconnect the plug at any time, avoid putting any obstacles near the outlet. Otherwise, it may not be possible to disconnect the plug in an emergency. Be sure to ground the equipment to an indoor grounded connector. Also, be sure to connect all the grounds for the system to a common ground. Do not use any power source other than the one provided with this equipment.
Wireless Digital Flat Panel Detector Mars1717X Do not operate close to fire, do not use in high temperatures Do not invert positive and negative poles Do not contact with metal in case of a short circuit Do not insert sharp objects into the battery Do not hit the battery Do not stand on the battery Do not use the battery for purposes other than those stipulated in the rules Do not dispose of the battery or change its internal structure Do not submerge the battery in water; please keep it dry in storage and
1. Safety Information The product should be warmed up for 15 minutes before exposure or updating the gain map and defect map. Make sure wave form of the energy going to the X ray tube is square not pulse. Be cautious with circumstance that someone has radio isotope recently injected into them, it may cause panel transmit image without x ray.
Wireless Digital Flat Panel Detector Mars1717X 2. GENERAL DESCRIPTION ................................................................................. 19 2.1. Scope ......................................................................................................... 19 2.2. Principle ..................................................................................................... 19 2.3. Model ........................................................................................................
2. General Description 2. General Description Mars1717X configuration Mars1717X, hereinafter referred as Mars1717X is a cassette-size wireless X-ray flat panel detector based on amorphous silicon thin-film transistor technologies. It is developed to provide the good quality of radiographic image, which contains an active matrix of 4267 4267 with 100 m pixel pitch. The scintillator of Mars1717X is CsI(Caesium Iodide) which is direct deposit.
Wireless Digital Flat Panel Detector Mars1717X 2.4.Characteristics Wireless static flat panel detector 17 inch inch Removable handle AED 802.11 a/b/g/n/ac 16-bit AD 2.5. Intended Use Mars1717X is indicated for digital imaging solutions designed to provide general radiographic diagnosis for human anatomy including both adult and pediatric patients. It is intended to replace film/screen systems in all general purpose diagnostic procedures. The device is not intended for mammography or dental applications.
2. General Description It is suitable for providing digital X-ray imaging for DR system to provide general radiographic diagnosis for human anatomy including both adult and pediatric patients, but not intended for mammography or dental applications. The remaining notes depend on the DR system.
Wireless Digital Flat Panel Detector Mars1717X obtain images that are adequate clinically. Additional guidance and recommendation are provided by the Alliance for Radiation Safety in Pediatric Imaging (Image Gently Alliance) https://www.imagegently.org/ Table 1 : Techniques for Typical Body Parts Body Parts Abdomen AP/PA Patient Size kVp mAs SID Grid Very Low Birth Weight (Less than 1.5Kg) 55 1 1m No Low Birth Weight (Between 1.5 and 2.5Kg) 55 1.6 1m No 70 1.
2. General Description AP/PA Low Birth Weight 55 1 1m no Newborn 57 1 1m no Infant 57 1.2 1m no Child 58 1.2 1m no Preadolescent 62 1.
Wireless Digital Flat Panel Detector Mars1717X Intended OPERATOR: All of use, maintenance and operation steps should be carried out by the operator who has accepted the professional training offered by the c 2.8. The relative position between patient and detector Because of the crosstalk effect of Amorphous silicon flat-panel detector, Pay attention to the relative position of patient and detector, the recommended position as shown below, Otherwise, the image is prone to abnormal light lines. 2.9.
2. General Description DC power cable 1pcs Battery charger 1pcs CD ROM 1pcs 2.10. Environment Temperature Variation Humidity Atmospheric Pressure 10~35 <1k/min 5%~90% RH 700~1060hPa -20~55 <1k/min 5%~95% RH 600~1060hPa Temperature Operating Transport &Storage (without battery) Atmospheric Pressure Variation <10kp/min (1kp=1.0197E-5Pa) <10kp/min (1kp=1.0197E-5Pa) 2.11. Components Dsecription 2.11.1.
Wireless Digital Flat Panel Detector Mars1717X 2.11.2. Button and Indicator NO. Item Description A DC Input Interface 24V DC input B Multi-Function Multi-Function Button C Status Indicator Detector Status indicator D Mode Indicator Detector WIFI mode indicator E Link Indicator Detector Link indicator F Power Indicator Detector Power indicator G Power Button Power button 2.11.3.
2. General Description Locate the logo at the top right corner, then the acquired image is mirrored on vertical direction.
Wireless Digital Flat Panel Detector Mars1717X 2.12. Product Specification 2.12.1.
2. General Description Effective Array 4267x4267 Effective Area (H x V) Spatial Resolution 426.7mm Min 4.3 lp/mm Image Transfer WIFI Full Image Time <5s Cycle Time 6s Power Consumption Dimension (L 26.7mm H) Weight Image Transfer Wireless Frequency Range Data Transmission Power Wireless Modulation Max 20W @No battery charging 460mmx460mmx15mm @typ. Max 3.4kg(with battery) Wireless : IEEE802.11 a/b/g/n/ac 2.412~2.472GHz, 5.18~5.22GHz; 5.745~5.85GHz 13dBm (Typ.) @802.11a 16dBm (Typ.) @802.
Wireless Digital Flat Panel Detector Mars1717X 2.12.2. Battery Item Model Rated Capacity Specifications Battery-KX Min. 4700mAh, Typ. 4900mAh @ Discharge 0.2C Nominal Voltage 11.55V Charge Voltage 13.2V Discharged End Voltage Charging Method Operating Temperature Storage Temperature Relative Humidity 9V CC-CV Charge 0 -+60 , Discharge-10 1 month-20 -+50 3 month -20 -+45 6 month -20 -+35 -+60 5%~95% 210 x 105 x 8 mm Weight 30 0.
2. General Description NO. Item Description A Battery Label / B Battery Interface 7-pin battery connector C Guide Block / D Touch Display Show battery level after touching 2.12.3. Battery Charger Item Model Simultaneous Charging Full charging time Rated power supply Specifications Charger-Combo 1 battery pack 3 hours 90V~264V(AC) 240.4 x 184.4 x 41.5 mm Weight User Manual of Mars1717X 0.
Wireless Digital Flat Panel Detector Mars1717X The battery charger indicator definition: Item Name Description A Power Indicator / B Charging Indicator / C Charge Full Indicator / X Indicator All off Lighting Status Operating Status No power input AC Power input A indicator on Multiple batteries inserted A indicator on Battery insertion self-test B and C alternately blink 2 times A and B Battery Charging indicator on A and C indicator on A indicator on B and C alternately blinking Bat
3. Basic Operation 3. BASIC OPERATION .......................................................................................... 34 3.1. Preparation ................................................................................................ 34 3.2. Routine Operation ..................................................................................... 35 3.3. Battery Charger Installation ........................................................................
Wireless Digital Flat Panel Detector Mars1717X 3. Basic Operation 3.1. Preparation 3.1.1. Attach Battery Pack The product can be powered by both a battery pack and DC power. Once the battery pack is inserted or DC power is connected, detectors will be turned on immediately. If neither battery nor DC power is connected, panel will power off. Please see below for battery installation. Make sure that connectors on the battery pack are pointed to the opening in the battery compartment.
3. Basic Operation No. Definition Voltage Range P1 DC Power Negative 0~0.5V P2 DC Power Positive 23~25V P3 DC Power Positive 23~25V P4 DC Power Negative 0~0.5V In order to meet the safety and function requirements of the detector, standard components are recommended. AC Adapter 3.2. Routine Operation 3.2.1. Starting Up On the control panel, users can press the power button to turn on.
Wireless Digital Flat Panel Detector Mars1717X After booting up, users can check the indicator of the detector.
3. Basic Operation Status indicator Mode Indicator Lighting Status Description OFF Detector is off Green ON Exposure is allowed Orange ON Error 3.3. Battery Charger Installation Operation Figure Unload Battery from battery charger. Insert battery into battery charger. Note the interface position as figure. Press the battery to the bottom of battery compartment.
Wireless Digital Flat Panel Detector Mars1717X 4. SOFTWARE SETUP .......................................................................................... 39 4.1. System requirement ................................................................................ 39 4.2. Environment setup................................................................................... 39 4.3. Wired Connection (for setting&maintenance) ......................................... 39 4.4. Software UI .................
4. Software Setup 4. Software Setup 4.1. System requirement iDetector is developed and deployed on Windows Operation System, it can be run on Windows XP/Windows 7/Windows 8/Windows 10, OS should install latest service pack. And requires computer memory 4 GB minimum. The firewall should be shut down to avoid commuication issue. 4.2. Environment setup Setup files and download url are included in SDK directory: Tools\env_setup 1. Please install Microsoft .NET Framework 4.5(Windows XP only can install V4.0 ).
Wireless Digital Flat Panel Detector Mars1717X On the main window of Home page Select the instance of Mars1717X the connection. After finishing building the get the current wifi configuration. to get default setting. Change SSID and password setting.
4.
Wireless Digital Flat Panel Detector Mars1717X Waiting 4.3.2. Client Mode Add: add the information of the access point, such as SSID and password. Select: Select the Access Point that needs to be connected to. 4.3.3.
4. Software Setup Select SSID which belongs to detectors; Input password and log into system Open wireless card configuration open IPV4 setting IP setting as follows IP address: 192.168.8.188 IP address: Subnet mask: 255.255.255.0 192.168.8.
Wireless Digital Flat Panel Detector Mars1717X 255.255.255.0 Open SDK and choose product start connection 4.4. Software UI SDK supply iDetector as tool softwore: 32-bits iDetector.exe: Tools\iDetector\w32 64-bits iDetector.exe: Tools\iDetector\x64 Double click iDetector.exe to run the software. For different software version, the UI maybe has little difference. For this manual, the example is based on SDK_*_xxxx. This UI is almost the same for different versions of iDetector. Tab Home Acquire SDK 4.4.1.
4. Software Setup The main function in this page is to connect detector. Item Name SN Product Type State Function description Display the name of detector Display the SN of detector Display the type of detector Display the connection state (Bind Button Connect 4.4.2. Unknown, Ready etc.) Function description Click this button to connect the selected detector. Close Click this button to disconnect the selected detector.
Wireless Digital Flat Panel Detector Mars1717X This page is used to acquire image under different work mode, and user can select correction options too. When acquire image finished there will be a preview image shown on the screen (if the correction option is selected, otherwise only the raw images will be shown).The propertities of image is displayed on the left of image window.And on the right of image window there is a list to show thumbnail of images.
4. Software Setup Functions in this Page. Correction Menu Description Offset HWPostOffset Do hardware PostOffset correction for image if checked Gain HWGain Do hardware Gain correction for image if selected Defect HWDefect Do hardware defect correction for image if checked Acqurie Button Description Prep Clear. Prepare to integrate.
Wireless Digital Flat Panel Detector Mars1717X Rotate the image clockwise, 90 degrees every time. Rotate the image anticlockwise, 90 degrees every time. Mirror Open or close mirror ROI ROI tool to view the image of the AVG, SV, SNR and other parameters with right click. Press "ctrl" key, can create several ROI area. WW/WL Auto adjust WW/WL based on selected area by right button of mouse.
4. Software Setup 4.4.3. SDK Pgae SDK page is used to set parameters in config.ini and log level. Different log level will show different details. It is recommended to set the log level as Debug 4.4.4. Detector Page In this page, there are Parameters, Sensor and Images tab. Parameters 1. Enter Detector page, the tab of Paramters is activity by default. There are 5 regions in this page. 2. Parameter name region: lists the paramters. 3.
Wireless Digital Flat Panel Detector Mars1717X Configuration parameters description as below: Name Product No. Configurable Type of detector product N Serial number of the detector N Main Version Firmware version number of the FPGA N Read Version N/A N MCU Version Firmware version number of the MCU N Arm Version Version number of the ARM App N Kernel Version Version number of ARM Kernel N Trigger Mode Tirgger mode of the detector Y Serial No.
4. Software Setup Button function description: Function Button Reset Detector Description Reset Detector Read Read parameters Write Write parameters Write RAM Write parameters into RAM(will lost changes after reset) Upgrade Firmware L Upgrade firmware Upload detector log to the specified directory Sensor The mainly function in this page is to probe the temperature and humidity of the detector. Click the value of the temperature or humidity.
Wireless Digital Flat Panel Detector Mars1717X Wifi User can config the wireless connect parameters on this tab. Images You can Query and upload Images from detector to Workstation.
4. Software Setup 4.4.5. Calibrate Page Offset, Gain, Defect calibrate files can be generated and managed in this page.
Wireless Digital Flat Panel Detector Mars1717X SubTab Description Mode&Files Manage template files Create Offset Create Offset template Create Gain Create Gain template Create Defect Create Defect template Mode&Files page Description Import to Workdir Copy template file into current calibration directory. Download to FPD Select one item first. Then click this button to download selected template file(s) into detector.
4. Software Setup UpdateHWPreOffset Force detector update Offset template ReadStatus Get the current state of template for hardware correction, enable/disable Generate Gain Template File If the relative position between tube and detector changed or KV value changed, it suggest to create gain template file. 1. Enter Create Gain page Click "Start" button to start process, the offset type should be selected, then start to get the images. 2. Click PREP button, then exposure after Acquire button enable.
Wireless Digital Flat Panel Detector Mars1717X The gain template generation process needs 5 images total, the UI gives the recommended KV and target value, user can use different ones if needed. After accepting the current image, the Stage will turn to 2/5, 3/5 and so on. The current value box will show different colors, the definitons are as below: Yellow: The current value is higher or lower than the expected one, user decides if acceptable.
4. Software Setup 4. When the generating process is finished, the UI will give the message of successful. Generate Defect Template File The process of generate defect map is quite similar with the one of gain map. 1. On the Create Defect page, user can start the generating process by Start button. And the process can be quit by Cancel .
Wireless Digital Flat Panel Detector Mars1717X 2. There are 8 images that need to be acquired, the UI gives the recommend KV and expected image value, user should refer with them. 3. If the option Download to FPD after generation is checked, the download UI will appear after finishing generating the defect map which will takes a little time. The field of Index in FPD means that the detector can store several correction maps and choose one set to active as user wants.
4. Software Setup Upload the correction files 1. The correction maps can be uploaded to the workstation too. Choose the gain or defect in the Fpd template files and the Default directory in the Subset settings , then click the Upload to workdir . 2. When the upload process is finished, the UI will give the message.
Wireless Digital Flat Panel Detector Mars1717X The correction maps should be enabled before using hardware correction, read status first, then choose the gain or defect, enable the map by clicking Active button. 4.4.6. Local Page In this page user can open the image files saved in local, the file formate can be dcm, raw, tiff, dft. When the software is disconnected to detector, the file still can be opened. or double click the file. The tiff file will be opened directly.
4. Software Setup This page provides ROI tool, which can see the AVG, SNR, and other properties of the choosen image area by right mouse button. This page provides WW/WL tool as Acquire page . Click this button to auto adjust WW/WL based on selected area by right button of mouse.
Wireless Digital Flat Panel Detector Mars1717X Rotate the image anticlockwise, 90 degrees every time. Mirror Open or close mirror ROI ROI tool to view the image of the AVG, SV, SNR and other parameters. Press "ctrl" key, can create several ROI area. WW/WL Auto adjust WW/WL based on selected area by right button of mouse. 4.5.
5. Operation Instructions For Image Acquisition 5. OPERATION INSTRUCTIONS FOR IMAGE ACQUISITION ............................ 64 5.1. Steps for acquiring image ........................................................................ 64 5.2. Software Mode ........................................................................................ 64 5.3. AED Mode ............................................................................................... 66 5.4. After use .............................
Wireless Digital Flat Panel Detector Mars1717X Operation Instructions for Image Acquisition Mars1717X provides SDK for users to integrate detector into their DR system. Additionally, it also provides an application for demonstration, i.e. IDetector. User can use IDetector to control detector without DR system. 4.6. Steps for acquiring image Make sure the hardware is connected correctly and then power on.
5. Operation Instructions For Image Acquisition 4.7.2. Work Flow(PrepAcq) Select HWPostOffset HWGain HWDefect. If user need the raw image, please de-select all these correction options. Also, the software correction is supported. Cmd_PrepAcq Ack_Prohibit Ack_Enable IDLE Prepare RAW Preview XWIN1 (fixed) RAW X-Ray image (If HW-offset is disabled) X-Ray imaging XWIN1 (fixed) RAW offset(Or corrected) image Offset imaging 1. 2.
Wireless Digital Flat Panel Detector Mars1717X 2. After receiving the Cmd_Prep, it will start the prepare process, and send back the acknowlage 3. The max 4. User starts the X-Ray. 5. 6. after the X-Ray is end. The preview image will be always sent, which is 4x4 averaging, the raw X-Ray image will be sent if the HW correction is disabled with the raw offset image follows, otherwise, the X-Ray image will not be sent and only the corrected image will be transferred. 4.8. AED Mode 4.8.1.
5. Operation Instructions For Image Acquisition 4.8.2. Freesync Mode X-Ray RAW Preview Info IDLE XWIN1 (fixed) X-Ray imaging RAW X-Ray image If HW-offset is disabled XWIN1 (fixed) RAW Offset(Or corrected) image Offset imaging 1. For Freesync mode, there is no low power state. 2. When the detector is Idle, user can start the exposure flow any time. 3.
Wireless Digital Flat Panel Detector Mars1717X 4.10.1. HW pre-offset Template Generation Enter Acquire interface, select HWPostOffset option Enter Calibrate interface, click UpdateHWPreOffset button. Waiting until status bar displayed: "Task succeed: 4.10.2. Gain Calibration Template Generation If the relative position between tube and detector changed or KV value changed, it suggest to create gain template file. Enter Create Gain page Click "Start" button to start process.
5. Operation Instructions For Image Acquisition Click PREP button, acquire image. Please exposure after Acquire button enable. And click Acquire button to acquire image after exposure end. Click Accept button after acquired image. If Current Value textbox is yellow, click PREP button. Re-acquire images after adjust generator parameters. Note: In different trigger mode, the operation maybe have little difference. Please follow the UI tips.
Wireless Digital Flat Panel Detector Mars1717X Select Mode&Files tab. Click Read Status button to check whether just downloaded gain template is enable. If not, please click Active button to enable. 4.10.3. Defect Correction Template Generation Enter Acquire UI. Choose HWPostOffset. Enter Calibrate UI. Select Create Defect tab. Click "Start" button to start process. Click PREP button, acquire image. Please exposure after Acquire button enable. And click Acquire button to acquire image after exposure end.
5. Operation Instructions For Image Acquisition Accept button after acquired image. If Current Value textbox is yellow , click PREP button. Reacquire images after adjust generator parameters. Note: In different trigger mode, the operation maybe have little difference. Please follow the UI tips. You can click Generate button to generate Gain template after acquired required images. Download template file dialog will pop up if "Download to FPD after generation" option was checked.
Wireless Digital Flat Panel Detector Mars1717X Select Mode&Files tab. Click Read Status button to check whether just downloaded gain template is enable. If not, please click Active button to enable. 4.11. Local Image Check Upload. Local Image Check defines function to check image saved in Workstation. Panel Image Upload defines function to upload images stored in panel. choose the specified file In this page user can open the image files saved in local, the file formate can be raw, tiff, dft.
5. Operation Instructions For Image Acquisition This page provides ROI tool, which can see the AVG, SNR, and other properties of the choosen image area by right mouse button. This page provides WW/WL tool as Acquire page . Click this button to auto adjust WW/WL based on selected area by right button of mouse.
Wireless Digital Flat Panel Detector Mars1717X The firmware upgrade package may contain firmware of several units: ARM, FPGA, MCU. Mars1717X_IMAGE_44_ALL_20XX_XX_XX.ifrm Mars1717X_IMAGE_44_ARM_20XX_XX_XX.ifrm s only for ARM. Mars1717X_IMAGE_44_FPGA_20XX_XX_XX.ifrm Mars1717X_IMAGE_44_MCU_20XX_XX_XX.ifrm User can choose one of these files as required to start the upgrade. Choose the file that needs to be upgraded, and must check the package info to confirm if it is correct.
5. Operation Instructions For Image Acquisition Note: 1. There is a progress bar for indication. Make sure battery is inserted and battery capacity is over 25% 2. Please make sure that iDetec there is firmware version.
Wireless Digital Flat Panel Detector Mars1717X 6. 76 REGULATORY INFORMATION ........................................................................ 77 6.1. Medical Equipment Safety Standards ..................................................... 77 6.2. ................................. 80 6.3. Radio Frequency Compliance Information .............................................. 81 6.4. Battery Safety Standards ........................................................................ 84 6.5.
6. Regulatory Information 6. Regulatory Information 6.
Wireless Digital Flat Panel Detector Mars1717X Requirements and tests IEC 60601-2-54:2009+A1:2015 Medical electrical equipment -- Part 2-54: Particular requirements for the basic safety and essential performance of X ray equipment for radiography and radioscopy EN 60601-2-54:2010+A1:2015 Medical electrical equipment -- Part 2-54: Particular requirements for the basic safety and essential performance of X ray equipment for radiography and radioscopy CAN/CSA-C22.2 No.
6. Regulatory Information 6.2 6.2.1 EMI Compliance Table Emissions Phenomenon Compliance Electromagnetic environment RF emissions CISPR 11 Professional healthcare facility environment Group 1, Class B Harmonic distortion IEC 61000-3-2 Professional healthcare facility environment Class A Voltage fluctuations and flicker 6.2.
Wireless Digital Flat Panel Detector Mars1717X 780 810 800-960 Pulse modulation 18Hz, 28V/m 1700-1990 Pulse modulation 217Hz, 28V/m 2450 2400-2570 Pulse modulation 217Hz, 28V/m 5240 5100-5800 Pulse modulation 217Hz, 9V/m 870 930 1720 1845 1970 5500 5785 Input a.c.
6. Regulatory Information inches) to any part of the [ME EQUIPMENT or ME SYSTEM], including cables specified by the Cable provided for EMC Cable Recommended length Shielded/Unshielded Number Cable classification AC power cable 1.8m Unshielded 1 piece AC power DC power cable 3m Shielded 1 piece DC power Ethernet cable 3.
Wireless Digital Flat Panel Detector Mars1717X EN 55035:2017+A11:2020 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 50566:2017 EN 62209-2:2010+A1:2019 IEC 62479:2010 6.3.1 FCC Compliance Contains module s FCC ID 2ACHK-01070189 The panel has been tested to comply with limits for a Class B digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
6. Regulatory Information Operation is subject to the following two conditions. The panel may not cause harmful interference. The panel must accept any interference received, including interference that may cause undesired operation. The panel generates, uses, and radiates radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications.
Wireless Digital Flat Panel Detector Mars1717X against the body with no separation. Although the SAR is determined at the highest certified power level, the actual SAR level of the device while operating can be well below the maximum value. This is because the device is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless Base station antenna, the lower the power output.
6. Regulatory Information 6.
Wireless Digital Flat Panel Detector Mars1717X Battery Charger Label 86 User Manual of Mars1717X
6.
Wireless Digital Flat Panel Detector Mars1717X 7. TROUBLE SHOOTING ......................................................................................
7. Trouble Shooting 7. Trouble Shooting Please refer to service manual. If the problem persists, turn off the panel and contact iRay service department (service@iraygroup.com).
Wireless Digital Flat Panel Detector Mars1717X 8. 90 SERVICE INFORMATION ................................................................................. 91 8.1. Service Office Information ....................................................................... 91 8.2. Product Lifetime....................................................................................... 91 8.3. Regular Inspection and Maintenance ...................................................... 91 8.4. Repair ...............
8. Service Information 8. Service Information 8.1 Service Office Information Service Office Tel +86 2150720560 Fax +86 2150720561 E-mail Location service@iRaygroup.com RM202, Building 7, No. 590, Ruiqing RD. , Zhangjiang East, Pudong 201201, Shanghai, P.R. China 8.2 Product Lifetime The estimated product lifetime is up to 7 years without frequency limit. 8.
Wireless Digital Flat Panel Detector Mars1717X Main parts (parts required to maintain the function of the product) of this product will be stocked for 5 years after discontinuance of production for repairing.
APPENDIX APPENDIX A INFORMATION OF MANUFACTURES .............................................................. 94 APPENDIX B INFORMATION OF EUROPE REPRESENTATIVE ............................................
Wireless Digital Flat Panel Detector Mars1717X Appendix A Information of Manufactures COMPANY: iRay Technology Co. Ltd. ADDRESS: Room 201, Building 9, No.590, Ruiqing Rd, Zhangjiang East, Pudong, 201201, Shanghai, P.R. China Building 45, No.
APPENDIX Appendix B Information of Europe Representative COMPANY: iRay Europe GmbH ADDRESS: IN DEN DORFWIESEN 14, 71720 OBERSTENFELD GERMANY User Manual of Mars1717X ZIP CODE: / TELEPHONE: +49-7062-977 88 00 FAX: +49-7062-976 0571 HOMEPAGE: WWW.IRAYEUROPE.