Application Notes

NOTE: Each PPU-300/301 power pack can supply
power for up to ? ON-BRD-500 sensors. When more
sensors are connected, multiple power packs may be
required.
MOUNTING
WIRING DIAGRAM
This device can be integrated with a luminaire or
mounted on the ceiling in various formats via specific
mounting bracket. Please refer to the mounting
instruction sheet separately attached for more details
about mounting options available.
0-10V Dimmable Lighting with Power Pack
OVERVIEW
The ON-BRD-500 series is a fundamental device of OS-NET wireless mesh network solution packed with multiple functionalities including occupancy/vacancy
sensing, daylight harvesting, bi-level StepDIM or continuous SmartDIM, and wireless network communication for top-notch intelligent lighting control.
Numerous design innovations allow this device to be flexibly integrated with an OEM luminaire, or mounted on the ceiling in a variety of options. Interchangeable lenses allow the
sensor to be mounted at various heights with different detection patterns for all applications. All functionalities can be easily and intuitively configured by a 2-way remote
programmer from the floor. With ON-BRD-500, you can effortlessly achieve energy efficient, code-compliant smart lighting control through a state-of-the-art wireless mesh network
synchronously established while installing the OS-NET enabled lighting.
APPLICATION NOTESSPECIFICATIONS
The sensor is more sensitive to the movements
“crossing” the detection zones than “toward” or
“away” the sensor unit. To obtain better sensitivity,
avoid placing the sensor in line with occupant path.
The closer the movement is to the sensor, the more
sensitive the sensor is. The higher the sensor is
installed, the larger movement is required to be
detected.
Ensure to place the sensor at least at 1.5m (5 ft.) away
from air supply ducts as rapid air flow may cause false
activations.
The sensor cannot “see” the movements behind
obstacles, such as tall furniture, shelf, glass or
partitions. Avoid placing the sensor where
obstructions may block the sensor’s line of sight.
The partition of workstation could block the sensor
view to occupant movements, it is best to place the
sensor over the intersection of workstation. For large
open office, place multiple sensors so that there is
overlap coverage with each adjacent sensor.
To obtain optimal wireless communication range,
avoid enveloping the sensor with a metallic enclosure.
1.
2.
3.
4.
5.
6.
P/N: 058-50906-003 Printed in Taiwanwww.irtec.com
This product may be covered by one or more U.S. patents or patent applications.
Please visit www.irtec.com for more information.
Low Voltage OS-NET Sensor
ON-BRD-500 series
INSTALLATION INSTRUCTIONS
Turn power OFF at circuit breaker before installing Power
Pack or Sensors.
Do NOT touch the square window of infrared sensor under
the lens assembly.
Do Not Install To and/or Cover a Junction Box Having
Class 1, 3 or Power and Lighting Circuits.
Class 2 Device Wiring Only – Do Not Reclassify and Install
as Class 1, 3 or Power and Lighting Wiring.
Install the sensor at least 1 ft. away from any occupant.
WARNING & CAUTION
Coupez l'alimentation au disjoncteur avant d'installer
Power Pack ou capteurs.
Ne PAS toucher la fenêtre carrée de capteur infrarouge
sous l'ensemble de l'objectif.
Ne pas installer ou couvrir une boîte de jonction ayant les
classes 1 et 3 ou circuits de puissance et d'éclairage.
Classe 2 Câblage de périphériques Seulement - Ne PAS
reclasser et installer Classe 1, 3 ou alimentation et circuits
d'éclairage.
AVERTISSEMENT & PRUDENCE
w/Lens A/B/C w/Lens D
w/Lens Gw/Lens F
*More lens options are available for this sensor.
Please refer to the Lens Datasheet for more details.
Federal Communication Commission Interference Statement
FCC ID: NRIRS35XY00
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
PRELIMINARY
Power voltage
Infrared sensor
Photo sensor
Sensor output
Dim controlt
Wireless protocol
Radio frequency
Number of channel
Radio range
Radio power output
Detectable speed
Mounting height
Detection range
Remote range
Op. humidity
Op. temperature
Dimensions
12-24 VDC
Digital quad-elemernt pyroelectric sensor
Digital ambient light sensor
Open collector, active low
0-10V, max. 25 mA sinking current
Modified Zigbee Light Link (ZLL)
2405-2480MHz
16ch
15/90 m @indoor/outdoor, open space
6.62dBm
0.3~3 m/sec. (1~10 ft./sec.)
Subject to the lens type applied
Subject to the lens applied and height
10m (33 ft) indoor with no backlight
Max. 95% RH
-40°C~55°C (-40°F~131°F)
Ø60 x H37mm (Ø2.36”x H1.45”)
ON-BRD-500
AODC+ DO
Black
White
Red
Red
Red
Black
Red
Black
Blue
Line
Neut
Relay
Relay
DC24V
DC
Control
Manual
Hold ON
Hold OFF
PPU-300/301
Power Pack
DIM+
120/277 VAC
Line
Neutral
DIM
L
N
BALLAST
LED DRIVER
1
2
Violet
Blue
DIM+
DIM
L
N
BALLAST
LED DRIVER
Non-dimmable Lighting with Power Pack
(ON-OFF Switching only)
ON-BRD-500
AODC+ DO
Black
White
Red
Red
Red
Black
Red
Black
Blue
Line
Neut
Relay
Relay
DC24V
DC
Control
Manual
Hold ON
Hold OFF
PPU-300/301
Power Pack
120/277 VAC
Line
Neutral
Load
Blue
Violet
Industry Canada statement:
Radiation Exposure Statement:
IC: 22993-5XYRS3DC900
This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de
brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage
susceptible de provoquer un fonctionnement indésirable.
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with greater than 20cm between the radiator & your
body.
Déclaration d'exposition aux radiations:
Cet équipement est conforme aux limites d'exposition aux rayonnements ISED établies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé à plus de 20 cm entre le radiateur
et votre corps.

Summary of content (2 pages)