Operating and Installation Manual
Table of Contents Safety Information .................................................................................................................. 3 FCC Statement....................................................................................................................... 4 For Canada: ........................................................................................................................... 4 Getting to know your AVO ............................................................
Safety Information WARNINGS • Use of equipment, components and accessories other than those specified by IQAir may impair safety provided by the equipment. Safety of any system incorporating the equipment is the responsibility of the installer of the system. • PoE power injector or USB adapter are not to be positioned so that it is difficult to unplug them.
FCC Statement Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Getting to know your AVO The IQAir AirVisual Outdoor air quality monitor, is designed to provide accurate, configurable and continuous air monitoring in covered outdoor areas. The monitor measures environmental parameters including temperature, humidity, pressure, CO2 and particulate matter. The device can be mounted vertically on walls and poles. Power can be supplied with the provided PoE Injector (PoE – Power over Ethernet) and included cable or via the optional USB adapter.
Component overview Air inlet temperature & humidity sensor Air inlets with insect mesh LED indicator Control button Micro-USB socket PoE Ethernet port Temperature & humidity sensor Air quality sensor modules Slots for additional air quality sensor modules Slot for USB 4G modem (two modules shown) Operating modes LED indicator Blue Connected to the IQAir cloud Red Not connected to cloud or network Red, blinking Resetting / updating / self-testing
Setup and Configuration The next few pages show how to install and configure the IQAir AirVisual Outdoor. First power the device with one of the two power options. Power can be supplied using the provided PoE injector (PoE - Power over Ethernet) and supplied Ethernet cable or via optional USB adapter and USB cable. Connect the device to the internet with one of the three network options. The IQAir AirVisual Outdoor is equipped with two built-in connection types, Wi-Fi and Ethernet.
Connecting to the internet Connection to the internet via Wi-Fi requires a few steps as shown in the IQAir AirVisual App, whereas connection via Ethernet or 4G should establish automatically the connection to the IQAir cloud and will not require network configuration in the App.
Mounting Instructions After successful network configuration, the device is now ready to be mounted in covered outdoor areas. Configure your AVO and confirm that it is connected to the internet and IQAir Cloud (blue LED) before starting with the installation Recommendations and considerations Installing The housing is designed to protect the device from the elements while allowing air to flow freely through the sensors. Always mount the AVO in a location with good air circulation.
Removing the mounting plate Loosen the hex socket screw with the supplied Allen key until the mounting plate can be released form the device. There is no need to remove the screw completely. Only in case you need to insert a USB 4G modem or replace an air quality sensor module, the mounting plate and air inlet cover needs to be removed from the IQAir AirVisual Outdoor.
Technical Specifications Size / Dimensions - 20.2 x 6.9 x 16.2 cm (length x width x height) Weight - 608 g Power - Standard: via provided PoE injector (48 VDC 0.25 A) or IEEE-802.3at capable Ethernet switch and Ethernet cable - Optional: via specified USB adapter (5.2 V 2.4 A) and USB to micro USB cable - Supply voltage Range: 100 to 240 V - Supply frequency Range: 50 to 60 Hz - Supply current max.: 0.
Join the Air Quality Community IQAir reports data for more than 10,000 locations worldwide. Yet, still many places lack local air quality monitoring stations. By making your AirVisual Outdoor public you can become an air quality data source for your local community. Together, we can raise air quality awareness and provide the global air quality data needed for people, businesses and governments to implement change. Visit us online for more information: iqair.