iPollo V1 mini Classic Series Server Setup Manual
V1 mini series server instruction manual V1 mini Classic Series have 4 models: (1)iPollo V1 mini Classic; (2)iPollo V1 mini Classic WiFi; (3)iPollo V1 mini Classic Plus; (4)iPollo V1 mini Classic Plus WiFi。 During use, only the network settings are different, and the versions are divided into WiFi version and wired connection version.
V1 mini series server instruction manual I. V1 mini Classic WiFi: Check Before Use 1. Sign For Inspection (1) When signing for the new server, please check whether the appearance of the package is damaged. If there is any damage, please take a picture and contact our after-sales service. (2) After opening the package, please check whether the server case is deformed, whether the fan and connecting cable are damaged, and whether the cable is damaged.
V1 mini series server instruction manual (3) Pay attention to dust and foreign matter, so as not to corrode the computing board or affect the heat dissipation of the server. (4) It is recommended to use Google browser or Firefox browser to browse the server background. (5) It is strictly forbidden to plug and unplug the power cable and signal cable under power. The AC side of the power supply of the server must be reliably grounded. II. V1 mini Classic WiFi: Product Introduction 1.
V1 mini series server instruction manual Fault The fault warning light. In most cases, when this light flash, it indicates that a fault has occurred Normal Running indicator light.
V1 mini series server instruction manual ETH 3. Network interface Notes (1) In the process of running the server, please place it as shown in the picture below, that is, keep it flat to avoid any damage to the server. (2) The socket shall be installed near the server and shall be easily accessible. (3) The two 6PIN power ports must be connected at the same time before the supplying power. (4) This product requires a power input of 100~240VAC to make the product work normally.
V1 mini series server instruction manual (2) Internet Connection (2-1) Wired Connection The interface marked “ETH” on the server interface panel is the network cable interface. Pay attention to the direction when inserting the cable. Please insert the crystal head in place. After inserting it in place, you will usually hear a light “click” sound. (2-2) WiFi Connection The red box in the picture is the WiFi antenna ,WiFi signal can be connected, For details, please visit “ipollo.com/support”.
V1 mini series server instruction manual 2. Log in to the Server 2.1 Find the server IP After the server is powered on and connected to the Internet, it starts to start. After the server’s normal starts to light up, you can find the IP of the server. You can use the “show IP” software to find the server IP as follows: (1) Download software: http://www.nano.cn/download/ShowIP.exe (2) Double-click “show IP” to open the software.
V1 mini series server instruction manual 2.2 Enter the Server Backstage Management System (1) After finding the IP of the server, enter the obtained IP address in the browser (Google is recommended), press Enter to enter the server login interface, and enter the default administrator account and password: root (2) press “Login” to enter the Server Backstage Management System as follows: 3.
V1 mini series server instruction manual 3.1 Fill in the Mining Pool Information Note: This manual takes the “antpool” as an example. ETC mining address: stratum+tcp:// 47.108.153.82:8008 (1)Select "Pool Configuration" and fill in the Mining Pool Information (1-1) The "Url" in "Mining Pool 1" is filled with the ETC AntPool mining link address: stratum+tcp:// 47.108.153.82:8008 (1-2) "Worker" in "Pool 1" fill in "ipollomini.
V1 mini series server instruction manual Note: In order to prevent “Pool 1” from being disconnected, causing the server to not work, it is recommended to set “Pool 2” and “Pool 3” at the same time, so as to ensure that the system will automatically switch to “Pool 2” or "Pool 3” for normal operation when “Pool 1” goes offline. 3.2 Network Settings Regarding network connection, V1 mini Classic Series products are divided into two models: "wired connection" and "WiFi connection".
V1 mini series server instruction manual After setting, click “SAVE&APPLY”, the system will save and automatically restart to take effect, and the server will start to run normally. End here, the configuration of the server has been completed, congratulations on your becoming a miner. (2-2) Select “Static” State (a) Enter the IP address, netmask, gateway, and DNS-Server in turn in the four boxes below, then click “SAVE&APPLY”.
V1 mini series server instruction manual Note: The protocol information filled in "Network Configuration" in the figure (staic) is for reference only, please refer to the on-site network protocol information for details. 3.2.2 WiFi connection (1) After the V1 mini Classic WiFi server is powered on, it will send out the WiFi signal "iPollo_XXXXX"; turn on the laptop and connect to the wireless signal "ipollo_XXXXX" (2) Browse the server's default IP address "192.168.2.
V1 mini series server instruction manual (4) Modify the SSID and corresponding password (please make sure there can be no errors, otherwise the server cannot connect to the correct network) (5) Click "Save and Apply" after editing - 14 -
V1 mini series server instruction manual (6) After the application, the server needs to be powered off and restarted; (7) The laptop is connected to the wireless signal "Nano (the network of the environment where the computer belongs)" (8)Open the showIP tool, and press the "IP report" button of the server to obtain the new IP address of the server, which is the IP of the WiFi setting.
V1 mini series server instruction manual (9) Use Google Chrome, log in to the IP displayed by the above tool showIP, you can enter the server management background, and fill in the mining pool information to complete the server settings. 3.
V1 mini series server instruction manual Note: The “Antpool” mining pool is used as an example above. If you use other mining pools, please modify it to the address of the mining pool you want to use and refer to the corresponding mining pool operation instructions. IV. WARNING This device complies with Part 15 of the FCC Rules.
V1 mini series server instruction manual This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.