Safety Information

Test Report
Report No. : TCT170727C902 Date : Aug. 01, 2017 Page No.: 1 of 32
Shenzhen TCT Testing Technology Co., Ltd.
1F, Building 1, Yibaolai Industrial Park, Qiaotou Village, Fuyong Town, Baoan District, Shenzhen, Guangdong
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Applicant: IPD Co., LTD
Address: (Bono-dong) 101 Eho-Ro 22,Sanrok-gu, Ansan-Si, Gyunggi-do, Korea
The following sample was submitted and identified by/on behalf of the client as:
Sample Name: Telephone Headset
Model No.: IPH-165 Binaural NC Headset.
Client Reference Information: IPH-160 Monaural NC Headset
Trade Mark: IPD
Sample Received Date:
2017.07.27
Testing Period:
2017.07.27—2017.08.01
Test Requested: According to customer’s requirements, Split the sample and determine the
Pb, Cd, Hg, Cr(VI), PBBs & PBDEs content of the parts.
Test Method: 1. Sample prepared with reference to IEC 62321-2:2013
2. Sample Screening testing with reference to IEC 62321-3-1:2013
3. Wet Chemical Test Method
a. Determination of Lead ,Cadmium by ICP-OES with reference to IEC
62321-5:2013
b. Determination of Mercury by ICP-OES with reference to IEC
62321-4:2013
c. Determination of Hexavalent Chromium in colourless and coloured
corrosion-protected coatings on metals by UV-VIS method reference to
IEC 62321-7-1:2015
d. Determination of Hexavalent Chromium in polymers and electronics
by UV-Vis Method with reference to IEC 62321:2008, Annex C
e. Determination of PBBs and PBDEs by GC-MS with reference to IEC
62321-6:2015
Test Result(s): Please refer to the following page(s).
Conclusion: Base upon the performed tests by submitted sample, the test results comply
with the limits as set by Directive (EU) 2015/863 - Amendment of EU RoHS
Directive 2011/65/EU (RoHS 2.0) Annex II.
Remark: Test data of this report was extracted from report No. TCT160517C001.
Checked by Signed for and on behalf of TCT
Chris Zhong Kim Zhang
Technical Manager