10.1.3 Upgrade firmware
The firmware is stored in the flash memory and can be updated with new versions to include new features
or to modify the existing one. This UBR has two partitions. The new firmware version is always uploaded
in the alternate partition (Backup Bank) to keep the current firmware image restored which is located in
the current partition (Active Bank) of UBR. When we upgrade the device with new firmware, the device
reboots and the new firmware from the alternate drive becomes the active firmware in current partition
(Active Bank) and the old firmware becomes the backup firmware in alternate drive (Backup Bank). If
any issues found in new firmware, the backup firmware will be booted.
A basic overview of the Backup/Flash Firmware screen to upgrade the firmware from an external file is
given below:
Figure 18: Basic overview of the backup/flash firmware screen to upgrade the firmware
Follow the steps given below to upgrade the firmware from an external file:
Table 13: List of actions to upgrade the firmware from an external file
1.
Maintenance
Click on Maintenancedropdown in navigation
tollbar
2.
Backup/Flash Firmware
Click on Backup/Flash Firmware option
3.
Selection box/Keep
settings
Click on Selection box to retain the existing device
configuration (or) deselect the Selection box to
discard the same while updating the firmware of the
device with a new version.
4.
Browse/Image
Click on Browse” option. A popup window will
appear on the screen. Go to the respective folder of
software file and select the sysupgrade-compatible
image to replace the running firmware. Refer image
below.