IXM TITAN Installation Guide
Table of Contents Glossary 3 Earth Ground 4 Device Handling and Cleaning 5 IXM Install Kit for TITAN 6 TITAN 7 I/O Cable: Top Connector Pin Out 10 I/O Cable: Bottom Connector Pin Out 11 Hardware Tools Required For Installation 12 Hardware Installation Steps 13 Connections for Power 17 Connections for Communication 19 Connections for Operation 23 Connections for HDMI Out 26 Software Installation System Requirements 27 Software Installation Steps 28 Notices 30 Support 34 INV
Glossary ACP Access Control Panel COM Common DAC Door Access Control DOS Door Open Schedule DSP Door Strike Power EGND Earth Ground ESD Electrostatic Discharge GND Ground IXM INVIXIUM LED Light Emitting Diode NC Normally Closed NO Normally Open OTG On-the-Go RLY Relay RX Receive SGND Signal Ground SPI Specific Purpose Input SPO Specific Purpose Output TX Transmit USB Universal Serial Bus WDATA Wiegand Data WGND Wiegand Ground VDC Volts Direct Current VIN+ Power
Earth Ground For protection against ESD, which may cause damage or malfunction to the IXM device, Invixium recommends the use of the ground connections between each IXM device and a high quality Earth Ground available at the install site. Please note that installation of any IXM device should be performed by licensed electricians. An Earth Ground wire with lug is provided in the IXM Install Kit. The lug of the Earth Ground wire should be fastened with a screw to the front of the mounting plate.
Device Handling Do's Handle with care, ensure not to drop or step on the device. Perform occassional cleaning to eliminate a build-up of dust, dirt, oil and residual grime. Device Handling Don'ts Do not install in areas with direct sunlight, high levels of humidity, extreme dust or flammable vapours. Do not allow magnetic objects to come in close contact to any device. Do not install near any heating elements or equipment.
The IXM Install Kit for TITAN includes: DO LP HIN IXM INSTALL KIT HIN LP HI DOLP DO N DOLP HIN DOLP HIN DOLP IN LP H HIN HIN LP HIN DO LP DOLPH DO DO LP HIN DO LPH IN IN DO LP HIN DO DOLP HIN Hex Key Wall Mounting Screws (qty 6) Dolphin Crimps (qty 12) Metal Mounting Plate Screw (qty 2) Wired Back Cover INVIX- Earth Ground Wire Metal Mounting Plate INVIXIUM Copyright 2019 Micro USB Extension Cable 6
TITAN Mic High intensity LED Flash Proximity Sensor 21 Megapixel Camera 5.
270.89 19.50 93.30 INVIXIUM Copyright 2019 89.13 81.
233 110 82.10 B 30 Front View 56 76.60 261.42 4.20 9.
I/O Cable: Top Connector Pin Out Wired Back Cover V_INPUT+ RLY_NO V_INPUT- RLY_COM RESERVED RLY_NC RESERVED RS485_T EGND RESERVED RESERVED Back View Front View RJ45 Receptacle RS232_RX RS232_TX SGND RS485_D+ RS485_DWDATA_IN0 RESERVED WDATA_IN1 WGND WDATA_OUT1 WDATA_OUT0 Wire Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 INVIXIUM Copyright 2019 Wire Color Label Application Green/Red Orange/White RESERVED RS232_RX Reserved for Future Use RS232 - Data Receive Green/Red Purple/White RESERVED
I/O Cable: Bottom Connector Pin Out Wired Back Cover DAC_IN2 DAC_IN3 DAC_IN1 DAC_IN_GND ACP_LED_GND RESERVED ACP_LED2 USB0_VBUS ACP_LED1 USB0_D- RESERVED USB0_D+ RESERVED DAC_SUPPLY USB0_GND Back View Front View SPO1 SPO2 USB1_GND SPO3 USB1_D+ USB1_DUSB1_VBUS SPO_GND SPI1 SPI2 RESERVED SPI3 RESERVED DAC_OUT SPI_GND Wire Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 INVIXIUM Copyright 2019 Wire Color Label Application Purple Orange/Yellow DAC_SUPPLY SPO1 Door Strike Power Specifi
Hardware Tools Required For Installation Battery powered Screwdriver Power Drill* Measuring Tape Hammer* Ratchet-style Crimping tool Pencil Manual Screwdriver Installation of any IXM device should be performed by licensed electricians. *Depending on the mounting surface, the Power Drill and Hammer may not be required.
1 Ensure Power is Off 2 IXM Install Kit This protects the device being installed. Remove the following items from the kit: LP N HI DO LP PHIN DOLPH DOLPHIN DOL DO HI N ON IN LP DOLPH HIN DO LP LP N HI DO LP DO HI N DOLPHIN HIN DO LP IN DOLPH DO LPHIN DO HI N IN OFF INVIX- 3 Mark the Screw Holes INVIXIUM recommends the use of all 6 holes for mounting. Refer to diagrams from page 9 onwards for actual dimensions.
5 Get Wires 6 Insert Screws Get access to the installation wires either from behind the wall or from the wiring conduit. Feed wires through the square hole of the mounting plate. Align the holes of the mounting plate with the wall anchors and attach the mounting plate with the screws provided in the IXM Install Kit. INVIXIUM recommends the use of an electric or battery-powered screwdriver for this step.
8A Make the Connections Connect the required wires using the Dolphin crimps provided in the IXM Install Kit (or any similar crimps) and a ratchet style crimping tool. Insert two wires (no stripping required) into the open end of the crimp and then using the crimping tool, clamp down on the middle of the crimp. HIN LP DO Earth Ground Wire Lug 8B Connect Earth Ground Connect the lug of the Earth Ground wire directly to the front of the mounting plate using one of the Wall mounting screws.
9 Attach the Device 10 Secure the Device Take the IXM device and unscrew the Temporary Back Cover, keeping the screws handy. Connect the Wired Back Cover to the back of the device by lining up the connectors. Secure the Wired Back Cover with the same screws.
Connections for Power UPS TITAN DC Power Supply VIN+ VIN- EGND INVIXIUM recommends: • 12-24 VDC regulated power supply (Safety tested and FCC/IC/CE certified) • Dedicated Power Supply for IXM TITAN (minimum 2A @ 12 VDC) • • Use of a battery back-up or UPS with built-in surge protection If sharing power supplies, ensure that each TITAN is supplied with minimum 2A per device (i.e.
TITAN FPU Connections for Power Over Ethernet (PoE+) Available on MERGE, SENSE 2, TOUCH 2 and TITAN TITAN FV INVIXIUM recommends: • A centralized Power Sourcing Equipment (PSE) for full PoE deployments (not included) • Use of a battery back-up or UPS with built-in surge protection Ethernet/PoE Connections TX+ TXRJ45_PIN4 Both IEEE 802.3at power transmission modes (A and B) are supported.
Ethernet and Wi-Fi Communication IXM WEB Ethernet: • Switch/Router required • CAT 5 cabling or better WiFi: • Wireless router to LAN/WAN • 802.
RS-485 Network Communication INVIXIUM recommends: • Daisy chain configuration • Maximum 31 devices in the network • Both RS-485 converter and the last device in the chain should be terminated (not included, refer to NOTE below for correct Resistor vaues) • • Connect the IXM device to PC via RS-485-to-Serial (RS-232 or USB) Converter Maximum cable length of 1200m (4000 ft.
Serial Communication TITAN IXM WEB 4 3 1 2 5 SG N 23 D 2_ RX RS 23 2_ TX RS USB-to-Serial B-to-Serial Converter RS-232 Connections RS-232: • Connect IXM device directly to the DB9 Serial port of the PC (if available) • DB9 connectors and cables are not included INVIXIUM Copyright 2019 RS-232_RX (2) RS-232_TX (4) SGND (6) 21
USB Communication TITAN Micro USB Cable Host PC USB: • Connect a Flash Drive via Micro USB OTG cable and perform functions like upgrading firmware and downloading transaction logs • USB port can also be used to connect to a PC running IXM WEB via Micro USB cable • Driver installation is required and will automatically initiate once the device is connected INVIXIUM Copyright 2019 22
Access Control Panel Connections for TITAN TITAN WDATA_OUT0 WDATA_OUT1 WGND ACP_LED1 ACP_LED2 ACP_LED_GND ACP: • LED and Wiegand connections available for ACP operation • INVIXIUM recommends the use of Wiegand Output Data 0, 1 and GND connection NOTE ACP_LED signals can be used if available on the Access Control Panel. IXM devices support up to 2 wires + GND for LED status.
Door Access Control Connections for TITAN TITAN RLY_NO L Snubber Diode RLY_COM L Door Strike Door Strike Power Supply DAC_IN1 Door Contact DAC_OUT DAC_OUT DA Request to exit DAC_IN2 DA DAC Connections (Top) DAC: • INVIXIUM recommends a separate power supply for Door Strike (not included) for this configuration • Snubber Diode required for Door Strike (not included) • Example above shows use of RLY_NO, but RLY_NC may be used instead if required by the Door Strike • Internal Relay rated upto max of 2
DAC Connections for TITAN when Device Powers Door Strike TITAN RLY_NO LY_ Snubber Diode RLY_COM L Door Strike VINDAC_SUPPLY DAC_IN1 Door Contact DAC_OUT C_ DA DAC_OUT Request to exit DAC_IN2 DA DAC: • IXM TITAN powers the door strike configuration.
Connections for HDMI Output TITAN’s wired back cover is equipped with an HDMI Out Port that can be used for real time Video Surveillance for standalone installations. When the HDMI out is connected to a monitor via an HDMI cable (sold separately), the monitor screen will show the user the TITAN Field of View when in surveillance mode. For security purposes, the HDMI cable can be connected to a monitor behind the door i.e. on the inside, to see what is happening on the outside.
Software Installation System Requirements To successfully install and run IXM WEB, the system must meet the following minimum requirements: PC Workstation: • • • • • ® ® 2 GHz Intel Pentium 4 or equivalent (2.4 GHz or higher recommended) 4 GB RAM (6 GB or higher recommended) 2 GB Free Hard Disk Space 850 MB Hard Disk Space for x86 systems or 2 GB Hard Disk Space for x64 systems Microsoft ®.NET Version 4.
Software Installation Steps Step 1 Go to ixmweb.invixium.com. Click Get IXM WEB. Provide the required details and Click “Submit”. An email with the latest IXM WEB Package will be sent to the email ID provided. (Contact Support if using a customized solution). Step 2 Download and Extract the package. Run IXM WEB.exe file. Step 3 There are two installation options: Install or Advanced. INVIXIUM recommends selecting INSTALL option for rapid installation.
Step 4 During the installation process, the status of the install will be shown. Step 5 When the installation is complete, click EXIT. IXM WEB icon is now on the desktop. Step 6 Run IXM WEB to launch the application in the default web browser to setup the Database and Admin credentials. Step 6 Visit the Invixium Customer Portal for more detailed manuals on invixium.com.
FCC Information to Users (English) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. NOTICE NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
NOTIFICATION NOTE Cet équipement a été testé et s'est avéré conforme aux limites pour un appareil numérique de Classe B, conformément à la partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle.
CE Information to Users (English) All INVIXIUM devices have the CE mark for conformance with EMC Directive 89/336/EEC, and Low Voltage Safety Directive 73/23/EEC. Device with RFID components are compliant with R&TTE Directive 1999/5/EC, and are Class 1 Devices. Informations de la CE aux Utilisateurs (en Français) Tous les dispositifs de INVIXIUM ont le marquage CE de conformité à la directive CEM 89/336/CEE et basse tension de sécurité Directive 73/23/CEE.
Warning to Users (English) WARNING Changes or modifications not expressly approved by INVIXIUM could void the user's authority to operate the equipment. Avertissement aux Utilisateurs (en Français) WARNING Les changements ou modifications non expressément approuvés par INVIXIUM pourraient annuler l'autorité de l'utilisateur à utiliser l'équipement.
For Technical or Customer Support issues, please contact your Local Authorized Reseller first. Contact Invixium Support at support@invixium.com. For detailed information, please visit our website. Enjoy the Experience. Some features may vary based on device models. Copyright © 2019, INVIXIUM. All rights reserved. P/N XAD-00E-151-02G INSTALLATION GUIDE INGUIDE INVIXIUM.COM © 2018 Google Inc. All rights reserved. Chrome™ browser is a trademark of Google Inc.