WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Low Profile 0.3 m / 0.5 m, Continued Procedure, continued Step Action 8 Install the antenna plastic cover, as shown below. 9 Perform the following actions: For installation of CONN-OB-U-DSDS to mounting kit follow the Procedure for WiBAS-Connect Combo on page 82 . For installation of CONN-OB-U-DSDS-DP to mounting kit follow the Procedure for WiBAS-Connect (auto-polarization) Combo on page 88 .
4. Installation Procedures WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps Introduction Apply this procedure for installing the following wireless equipment: WiBASTM-Connect terminal radio unit (CONN-OB-U-DSDS). Low profile parabolic antenna, 0.6 m (ANT-IS-2628-2F-C). WiBASTM-Connect terminal radio unit (CONN-OB-U-DSDS-DP). Low profile parabolic antenna, 0.6 m (ANT-DP-2628-2F-C). WiBASTM-Connect terminal radio unit (CONN-OB-U-DSDS). Parabolic antenna, 0.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.
. Installation Procedures WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Radio unit packing materials CONN-OB-U-DSDS Details TM WiBAS -Connect terminal radio unit. CONN-OB-U-DSDS-DP Details WiBASTM-Connect terminal radio unit auto-polarization edition. Antenna packing materials ANT-IS-26-1F Details 0.3 m antenna. Mounting kit. Greasing paste. Installation leaflet.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.6 m antenna How to install WiBASTM-Connect (CONN-OB-U-DSDS) to 0.6 m antenna (ANT-IS-2628-2F-C) with clamps or WiBASTM-Connect (CONN-OB-UDSDS-DP) to 0.6 m antenna (ANT-DP-2628-2F-C) with clamps, proceed as follows: Step Action 1 Install antenna clamps as described to antenna installation instruction leaflet.
4. Installation Procedures WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.6 m antenna, continued Step 3a Action TM For WiBAS -Connect (CONN-OB-U-DSDS) to 0.6 m antenna (ANT-IS-2628-2F-C) with clamps, proceed as follows: Radio unit and antenna should be adjusted for common polarization, as shown below.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.6 m antenna, continued Step Action 3b WiBASTM-Connect (CONN-OB-U-DSDS-DP) to 0.6 m antenna (ANT-DP-2628-2F-C) with clamps, proceed as follows: Follow the radio unit label, as shown below.
4. Installation Procedures WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.6 m antenna, continued Step Action 4 Unlock the four antenna clamps, as shown below. 5 Lubricate the O-ring with silicone grease, as shown below.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.6 m antenna, continued Step Action 6 Unlock the four antenna clamps, as shown below. 7 Mount the radio unit onto the antenna, as shown below.
4. Installation Procedures WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.6 m antenna, continued Step 8a Action TM For WiBAS -Connect (CONN-OB-U-DSDS) to 0.6 m antenna (ANT-IS-2628-2F-C) with clamps, proceed as follows: Lock and secure all four clamps according to the pattern below.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.6 m antenna, continued Step Action 8b WiBASTM-Connect (CONN-OB-U-DSDS-DP) to 0.6 m antenna (ANT-DP-2628-2F-C) with clamps, proceed as follows: Lock and secure all four clamps according to the pattern below. Details of Clamps closing 9 For cables installation refer to Installing Radio Units Cables . End of procedure.
4. Installation Procedures WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.3 m antenna and adaptation plate How to install WiBASTM-Connect (CONN-OB-U-DSDS) to 0.3 m antenna (ANT-IS-26-1F) with adaptation plate (WCONN-PAR-ANT-KIT), proceed as follows: Step Action 1 Remove antenna protection label from the feeder, as shown below. 2 Radio unit and antenna should be adjusted for common polarization, as shown below.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.3 m antenna and adaptation plate, continued Step Action 3 Use the respective set of adaptation plate packing materials to install the elements, as shown below. Use the adjustable torque wrench with hexagon female bit to tighten the screws. Do not over tighten the screws.
4. Installation Procedures WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.3 m antenna and adaptation plate, continued Step Action 4 Unlock the four antenna clamps, as shown below. 5 Lubricate the O-ring with silicone grease, as shown below. 6 Mount the radio unit onto the antenna, as shown below.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Parabolic 0.3 m with Adaptation Plate / 0.6 m with Clamps, Continued Procedure using 0.3 m antenna and adaptation plate, continued Step 7 Action Lock and secure all four clamps according to the pattern below. Details of Clamps closing 8 For cables installation refer to Installing Radio Units Cables . End of procedure.
4. Installation Procedures WiBAS-Connect and Panel Introduction Apply this procedure for installing the following wireless equipment: WiBASTM-Connect terminal radio unit (CONN-OB-U-DSDS). Antenna, panel, 10.5 GHz (ANT-IS-11-PL-C). Pole mounting kit (WCONN-PL-MNT).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Panel, Continued Radio unit packing materials Antenna packing materials CONN-OB-U-DSDS Details WiBASTM-Connect terminal radio unit. ANT-IS-11-PL-C Details Antenna, panel, 10.5 GHz. Antenna Set: M5 x 40 mm screws (x4). M5 x washers (x4). M5 x lock washers (x4). Silicone grease mini-pack.
4. Installation Procedures WiBAS-Connect and Panel, Continued Mounting kit packing materials WCONN-PL-MNT Details Azimuth bracket (A). Elevation bracket (B). Pole bracket (C). U-BOLT, M8 x 100 mm (D). U-BOLT bracket (E). Set-A: M8 x 25 mm screws (x4). M8 washers steel (x4). M8 lock washers (x4). Set-B: M8 x 25 mm screws (x4). M8 washers (x4). M8 lock washers (x4). Set-C: M5 x 40 mm screws (x4). M5 nuts flange serrated (x4). M5 washers (x4).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Panel, Continued Precautions During installation, the antenna plastic cover should be protected in order to avoid any damage. The WiBASTM-Connect terminal station (radio) polarization at 10.
4. Installation Procedures WiBAS-Connect and Panel, Continued Procedure for HORIZONTAL antenna orientation How to install WiBASTM-Connect to panel antenna in HORIZONTAL polarization, proceed as follows: Step 1 Action Mount the azimuth bracket onto the pole bracket and then install the respective set of mounting kit packing materials, as shown below: Do not over tighten the screws. Adjust the tool for applying max tightening torque 15 Nm.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Panel, Continued Procedure for HORIZONTAL antenna orientation, continued Step 2a Action For installing the pole bracket onto the pole perform the respective actions A, B, C and D, as shown below. For installing the pole bracket onto the pole using hose clamps go to the next step. Do not over tighten the nuts. Overtightening will cause deformation of the support clamp.
4. Installation Procedures WiBAS-Connect and Panel, Continued Procedure for HORIZONTAL antenna orientation, continued Step 2b Action Pass through both clamps to pole bracket openings and then install the whole assembly onto the pole (taking into the account the caution below): Do not over tighten the warm screws. Adjust the tool for applying min / max tightening torque 5.5 / 7 Nm.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Panel, Continued Procedure for HORIZONTAL antenna orientation, continued Step Action 3 For horizontal link polarization set in position both units to adjust the feeders, as shown below (radio unit – both side view): 4 Perform the following actions: Lubricate the antenna O-ring with silicone grease (A). Remove antenna protection plastic sticker from the feeder (B).
4. Installation Procedures WiBAS-Connect and Panel, Continued Procedure for HORIZONTAL antenna orientation, continued Step 5 Action Perform the following actions: Remove antenna wave giude protection sticker. Use the Antenna Set of antenna packing materials to install the elements, as shown below. Do not over tighten the screws. Adjust the tool for applying max tightening torque 4.2 Nm.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Panel, Continued Procedure for HORIZONTAL antenna orientation, continued Step Action 6 Mount the elevation bracket onto the azimuth bracket and then install the respective set of mounting kit packing materials, as shown below: Do not over tighten the screws. Adjust the tool for applying max tightening torque 15 Nm. 7 For cables installation refer to Installing Radio Units Cables . End of procedure.
4. Installation Procedures WiBAS-Connect and Panel, Continued Procedure for VERTICAL antenna orientation How to install WiBASTM-Connect to panel antenna in VERTICAL polarization, proceed as follows: Step 1 Action Mount the azimuth bracket onto the pole bracket and then install the respective set of mounting kit packing materials, as shown below: Do not over tighten the screws. Adjust the tool for applying max tightening torque 15 Nm.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Panel, Continued Procedure for VERTICAL antenna orientation, continued Step 2a Action For installing the pole bracket onto the pole perform the respective actions A, B, C and D, as shown below. For installing the pole bracket onto the pole using hose clamps go to the next step. Do not over tighten the nuts. Overtightening will cause deformation of the support clamp.
4. Installation Procedures WiBAS-Connect and Panel, Continued Procedure for VERTICAL antenna orientation, continued Step 2b Action Pass through both clamps to pole bracket openings and then install the whole assembly onto the pole (taking into the account the caution below): Do not over tighten the warm screws. Adjust the tool for applying min / max tightening torque 5.5 / 7 Nm.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Panel, Continued Procedure for VERTICAL antenna orientation, continued Step Action 3 For vertical link polarization set in position both units to adjust the feeders, as shown below (radio unit – both sides view): 4 Perform the following actions: Lubricate the O-ring with silicone grease (A). Remove antenna protection plastic sticker from the feeder (B).
4. Installation Procedures WiBAS-Connect and Panel, Continued Procedure for VERTICAL antenna orientation, continued Step Action 5 Mount the elevation bracket onto the radio unit and then install the respective set of mounting kit packing materials, as shown below: Do not over tighten the screws. Adjust the tool for applying max tightening torque 4.2 Nm.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS-Connect and Panel, Continued Procedure for VERTICAL antenna orientation, continued Step Action 7 Mount the elevation bracket onto the azimuth bracket and then install the respective set of mounting kit packing materials, as shown below: Do not over tighten the screws. Adjust the tool for applying max tightening torque 15 Nm. 8 For cables installation refer to Installing Radio Units Cables . End of procedure.
4. Installation Procedures WiBAS OSDR-TS and Parabolic 0.3 m Introduction Apply this procedure for installing the following wireless equipment: WiBASTM OSDR-TS radio unit (OSDR-OB-U-DSDS-SB). Parabolic antenna, 0.3 m (ANT-IS-26-1F).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS OSDR-TS and Parabolic 0.3 m, Continued Radio unit packing materials OSDR-OB-U-DSDS-SB Details Antenna packing materials WiBASTM OSDR-TS radio unit. ANT-IS-26-1F Details Antenna. Mounting kit. Greasing paste. Installation leaflet. Precautions It is very important to mount the antenna exactly as described to INSTALLATION INSTRUCTION LEAFLET (included in the antenna package).
4. Installation Procedures WiBAS OSDR-TS and Parabolic 0.3 m, Continued Procedure, continued Step 2 Action Radio unit and antenna should be adjusted for common polarization, as shown below.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS OSDR-TS and Parabolic 0.3 m, Continued Procedure, continued Step Action 3 Lubricate the antenna feeder O-ring with silicone grease. 4 Unlock the four clamps of the radio unit, as shown below. 5 Mount the WiBASTM OSDR-TS onto the antenna, as shown below. 6 Lock and secure all four clamps according to the pattern below Details of Clamps closing 7 For cables installation refer to Installing Radio Units Cables .
4. Installation Procedures WiBAS OSDR-TS and Panel Introduction Apply this procedure for installing the following wireless equipment: WiBASTM OSDR-TS radio unit (OSDR-OB-U-DSDS-SB). Pole/Wall mounting kit (OSDR-ANT-MNT). Antenna, panel, 10.5 GHz (ANT-IS-11-PL-C). Antenna adaptation kit (OSDR-PL-ANT-KIT). Pole adaptation bracket (optional) (INST-ADAPT).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS OSDR-TS and Panel, Continued Radio unit packing materials Antenna packing materials OSDR-OB-U-DSDS-SB Details WiBASTM OSDR-TS Radio unit. ANT-IS-11-PL-C Details Antenna, panel, 10.5 GHz. Used only for WiBAS-Connect and Panel Silicone grease mini-pack. Mounting kit packing materials OSDR-ANT-MNT Description A: Mounting adapter. B: Arm. C: Arm bracket. D: Azimuth / elevation adjusters (x2).
4. Installation Procedures WiBAS OSDR-TS and Panel, Continued Pole adaptation packing materials INST-ADAPT Antenna adaptation packing materials OSDR-PL-ANT-KIT Details A: Hose clamps for pole diameter 80 mm up to 100 mm (x2). B: Hose clamps for pole diameter 104 mm up to 120 mm (x2). C: Adaptation Bracket. D: M8 washers (x4). E: M8 x 25 mm screws (x4). Details Hooks (x4). M3 x 8 mm screws (x8).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS OSDR-TS and Panel, Continued Procedure, continued Step Action 2 Choose the proper hose clamps of the pole adaptation packing materials, based on the pole diameter. 3 Choose the correct position onto the pole to install the bracket. 4 Use the adjustable wrench with hexagon female bit to tighten. Do not over tighten the M5 warm screws. Adjust the tool for applying min 5.5 Nm and max 7 Nm tightening torque.
4. Installation Procedures WiBAS OSDR-TS and Panel, Continued Procedure, continued Step Action 6 For pole installation with pole diameter 48 mm to 60 mm, perform the following actions: Unscrew the Set-A of mounting kit packing materials (A). Release the u-bolts (B). 7 Place the arm bracket to the pole and install the two U-bolts, as shown below. Use the U-wrench to tighten (washer, lock washer and nut). Do not over tighten the M5 nuts. Adjust the tool for applying max tightening torque 15 Nm.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS OSDR-TS and Panel, Continued Procedure, continued Step 8 Action Perform the following actions: Unscrew the four screws (A). Place the radio mounting adapter onto the radio unit, as shown below (B). Use the wrench tool with hexagon male bit to tighten the screws (C). Do not over tighten the Μ5 screws. Adjust the tool for applying max tightening torque 4.2 Nm. 9 Insert arm into the arm bracket, as shown below.
4. Installation Procedures WiBAS OSDR-TS and Panel, Continued Procedure, continued Step Action 10 Perform the following actions: Place the azimuth adjuster (A) Install the set-A of mounting kit packing materials (B), as shown below: 11 Use the wrench tool with hexagon male bit to fully tighten the adjuster screw. Do not over tighten the screws. Adjust the tool for applying max tightening torque 20 Nm.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS OSDR-TS and Panel, Continued Procedure, continued Step Action 12 The installation should appear, as follows: 13 Use the cross screw driver to install the antenna adaptation packing materials (x4), as shown below.
4. Installation Procedures WiBAS OSDR-TS and Panel, Continued Procedure, continued Step Action 14 Radio unit and antenna should be adjusted for common polarization. If the LINK polarization is HORIZONTAL then the feeders should be remained, as shown below: If the LINK polarization is VERTICAL, use the allen key to loosen the four screws at the waveguide port of the radio (do not remove the screws) and then TURN the polarizer, as shown below: The terminal station polarization at 10.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS OSDR-TS and Panel, Continued Procedure, continued Step Action 15 Perform the following actions: Lubricate the O-ring with silicone grease (A). Remove antenna protection plastic sticker from the feeder (B). 16 Unlock the four radio unit clamps, as shown below.
4. Installation Procedures WiBAS OSDR-TS and Panel, Continued Procedure, continued Step 18 Action Lock and secure all four clamps according to the pattern below. Details of Clamps closing 19 End of procedure. For cables installation refer to Installing Radio Units Cables .
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 WiBAS OSDR-TS and Panel, Continued Procedure, continued Step 20 Action Use a drilling machine (fitted with an 8 mm drill bit) and the following drill template to drill the holes in the wall surface, as shown below.
4. Installation Procedures WiBAS OSDR-TS and Panel, Continued Procedure, continued Step 21 Action Insert items (W, A, J, I X) with order, as shown below: The items X, W listed below are not provided: Item 22 Description X Wood screw 5 x 50 mm, hex-headed, DIN571 4 I Lock washer M5, stainless 4 J Washer M5, stainless. 4 A Arm Bracket 1 W Wood plug 8 mm, plastic, type B.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 4.2. Installing Radio Units Cables Introduction This section describes the installation procedures for radio unit cables, as follows: Description WiBASTM G5 Connect+ WiBASTM-Connect WiBASTM OSDR-TS Grounding Cable ETH Cable Cable Holder For powering of power injectors refer to Appendix B – Terminating Cables in paragraph Power.
4. Installation Procedures Grounding Cable Introduction Apply this procedure for installing the grounding cables (GND-KIT16-OD and GND-CAB6-ID) to the following radio units: WG5-CONN-PLUS-LB-UB CONN-OB-U-DSDS CONN-OB-U-DSDS-DP OSDR-OB-U-DSDS-SB Precautions Ensure that: the Safety Precautions on page 17 are applied. Prerequisites Prepare and terminate the grounding cables as described in Appendix B – Terminating Cables.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 Grounding Cable, Continued Procedure for WiBAS G5 Connect+ How to install the grounding cable to radio unit (WG5-CONN-PLUS-LBUB), proceed as follows: Step Action 1 Use the tool (adjustable torque wrench with hexagon female bit) to remove the pre-installed M5 grounding nut. 2 Perform the following actions: Install the cable, as shown below.
4. Installation Procedures Grounding Cable, Continued Procedure for WiBASConnect (both editions) How to install the grounding cable to radio units (CONN-OB-U-DSDS / CONN-OB-U-DSDS-DP), proceed as follows: Step Action 1 If the terminal lug is installed then follow this step. If the terminal lug is not installed then follow step 2. Use the tool to remove the pre-installed M5 grounding terminal. 2 Perform the following actions: Install the cable, as shown below.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 Grounding Cable, Continued Procedure for WiBAS OSDRTS How to install the grounding cable to radio unit (OSDR-OB-U-DSDS-SB), proceed as follows: Step Action 1 Use the tool to remove the M5 nut and one spring washer. 2 Perform the following actions: Install the cable, as shown below: Use the tool with M5 hexagon female bit to fully tighten the screw. Do not over tighten the M5 nut.
4. Installation Procedures ETH Cable Introduction Apply this procedure for installing the ETH cable to the following radio units: WG5-CONN-PLUS-LB-UB CONN-OB-U-DSDS CONN-OB-U-DSDS-DP OSDR-OB-U-DSDS-SB Precautions Ensure that: the Safety Precautions on page 17 are applied. Prerequisites Prepare and terminate the ETH cable as described in Appendix B – Terminating Cables. Tools and materials Tools Adjustable torque U-wrench and screwdrivers (see Equipment installation tools).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 ETH Cable, Continued Procedure How to install the ETH cable to radio unit (WG5-CONN-PLUS-LB-UB / CONN-OB-U-DSDS / CONN-OB-U-DSDS-DP), proceed as follows: Step Action 1 Perform the following actions: Unscrew the sealing nut (A). Use the screwdriver for pushing forward the plastic protection in the middle of the seal (B). Use the screwdriver for pulling outwards the seal (C). Remove the plastic part (D).
4. Installation Procedures ETH Cable, Continued Procedure, continued Step 2 Action Pass the cable through the parts of gland, as shown below. The seal shown below is split-type for easy installation and removal. Insert and install the RJ-45 jack of the cable into the mating receptacle radio unit. Listen for a “click” when inserting. This verifies that the jack has been inserted properly. 3 Use the U-wrench to tighten. Do not over tighten. Adjust the tool for applying maximum tightening torque 5 Nm.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 ETH Cable, Continued Procedure, continued Take care when you unplug the RJ-45 jack. The latter is locked into the mating receptacle. After removing the gland parts of the cable use the flat-headed screwdriver to extract the RJ-45 jack by pressing the clip upwards, as shown below: End of procedure.
4. Installation Procedures ETH Cable, Continued Procedure How to install the ETH cable to radio unit (OSDR-OB-U-DSDS-SB), proceed as follows: Step Action 1 Remove the protective cap (plastic for GbE2 or metallic for FE). 2 Disassemble the M20-GLAND parts, as shown below: 3 Pass the cable through the parts of gland, as shown below. The seal shown below is split-type for easy installation and removal.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 ETH Cable, Continued Procedure, continued Step 4 Action Plug the RJ-45 jack into the GbE2 or FE port of the WiBASTM OSDR-TS. Listen for a “click” when inserting. This verifies that the jack has been inserted properly. 5 Perform the following actions: Use the U-wrench to screw the body into the radio thread (A). Do not over tighten. Adjust the tool for applying maximum tightening torque 7 Nm.
4. Installation Procedures ETH Cable, Continued Procedure, continued Step 6 Action Perform the following actions: Insert the seal into “pressure fingers” of claw (A). Insert the O-ring (B). Screw the sealing nut (C). Use the U-wrench to fully tighten. The metallic O-ring protects from overtightening.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 ETH Cable, Continued Procedure, continued Step 7 Action Install the cable to holder, as described in Cable Holder. Take care when you unplug the RJ-45 jack. The latter is locked into the mating receptacle. After removing the gland parts of the cable use the flat-headed screwdriver to extract the RJ-45 jack by pressing the clip upwards, as shown below: End of procedure.
4. Installation Procedures Cable Holder Introduction Tools and materials Apply this procedure for installing the cable holder (OSDR-HOLD-2) to radio unit OSDR-OB-U-DSDS-SB. Tools Adjustable torque wrench tool with hexagon male bit (refer to Equipment installation tools).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 Cable Holder, Continued Procedure How to install the cable holder to WiBASTM OSDR-TS radio unit, proceed as follows: Step Action 1 Use the wrench tool to remove the three screws with lock washers, as shown below. 2 Perform the following actions: Mount the holder to radio (A). Use the wrench tool to install the three lock washers and screws (B), as shown below: Do not over tighten.
4. Installation Procedures Cable Holder, Continued Procedure, continued Step 3 Action Use the tie wrap to tighten the cable, as shown below: End of procedure.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.
Appendix A - Installing Power Injectors POE-AC75-ID / POE-ID-AC72 / POE-AC56-IDH / POE-ID-AC35 Introduction Apply this procedure for installing the indoor AC power injectors POEAC75-ID / POE-ID-AC72 / POE-AC56-IDH / POE-ID-AC35. Power injectors details POE-AC75-ID: AC POE injector, indoor, 75 W, -20 C to +40 C, 90 V AC to 264 V AC, 47 Hz to 63 Hz. POE-ID-AC72: AC POE injector, indoor, 72 W, -5 C to +45 C, 100 V AC to 240 V AC, 50 Hz to 60 Hz.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 POE-AC75-ID / POE-ID-AC72 / POE-AC56-IDH / POE-ID-AC35, Continued Power injectors overview POE-AC75-ID # Marking Details Use A INPUT 3-pins AC socket (EU). To connect the AC power supply cord. B LED Multi-functioning LED. To provide equipment status during operation. C IN / OUT Gigabit Ethernet 10/100/1000 Base T, Electrical (RJ-45).
Appendix A - Installing Power Injectors POE-AC75-ID / POE-ID-AC72 / POE-AC56-IDH / POE-ID-AC35, Continued POE-ID-AC72 Power injectors overview, continued # Marking Details Use A INPUT 3-pins AC socket (EU). To connect the AC power supply cord. B LED Multi-functioning LED. To provide equipment status during operation. C LAN / POE Gigabit Ethernet 10/100/1000 Base T, Electrical (RJ-45).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 POE-AC75-ID / POE-ID-AC72 / POE-AC56-IDH / POE-ID-AC35, Continued POE-AC56-IDH Power injectors overview, continued # Marking Details Use A INPUT 3-pins AC socket (EU). To connect the AC power supply cord. B LED Multi-functioning LED. To provide equipment status during operation. C IN / OUT Gigabit Ethernet 10/100/1000 Base T, Electrical (RJ-45).
Appendix A - Installing Power Injectors POE-AC75-ID / POE-ID-AC72 / POE-AC56-IDH / POE-ID-AC35, Continued POE-ID-AC35 Power injectors overview, continued # Marking Details Use A INPUT 3-pins AC socket (EU). To connect the AC power supply cord. B LED Multi-functioning LED. To provide equipment status during operation. C IN / OUT Gigabit Ethernet 10/100/1000 Base T, Electrical (RJ-45).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 POE-AC75-ID / POE-ID-AC72 / POE-AC56-IDH / POE-ID-AC35, Continued Precautions Ensure that: the Safety Precautions on page 17 are applied. Prerequisites Prepare and terminate the ETH cable as described in Appendix B – Terminating Cables. Prepare and terminate the grounding cable as described in Appendix B – Terminating Cables (only for POE-ID-AC72).
Appendix A - Installing Power Injectors POE-AC75-ID / POE-ID-AC72 / POE-AC56-IDH / POE-ID-AC35, Continued Procedure How to install the cables (Ethernet, power and grounding), proceed as follows: Step Action 1 For POE-ID-AC72 install the grounding cable. 2 Connect the Gigabit Ethernet (S-FTP) cable to IN or LAN receptacle of the power injectors. Then connect the other end of the cable to customer network receptacle.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 PONE-OD67-AC Introduction Apply this procedure for installing the outdoor AC power injector PONEOD67-AC. Power injector details Characteristics: AC PONE injector Outdoor 67 watt Wall mount Temperature hardened Operating temperature -40 C to +55 C 110 V AC to 240 V AC, tested for 99 V AC to 255 V AC 50 Hz to 60 Hz IEC 60529 / IP67 class.
Appendix A - Installing Power Injectors PONE-OD67-AC, Continued Power injector overview # Marking Details Use A GND Grounding point. To connect 16 mm 2 grounding cable. B AC-IN 3-pins AC receptacle. To connect AC power supply cable with connector. C Gbe OUT Gigabit Ethernet 10/100/1000 Base T, Electrical (RJ-45).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 PONE-OD67-AC, Continued Precautions Ensure that: the Safety Precautions on page 17 are applied. Prerequisites Prepare and terminate the following cables: ETH cable as described in Ethernet (S-FTP). Grounding cable as described in Grounding. Power supply cable as described in Power.
Appendix A - Installing Power Injectors PONE-OD67-AC, Continued Procedure How to install the PONE-OD67-AC onto the pole or wall, proceed as follows: Step 1 Action For pole installation follow this step. For wall installation go to last step. Perform the following actions: Attach the plate onto rear side of PONE (A), as shown below. Install lock washer and screw. Then use the cross headed screwdriver to fully tighten (B). Pass the hose clamp through the plate holes (C). Install the PONE onto pole.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 PONE-OD67-AC, Continued Procedure, continued Step 2 Action Pass the cable through the parts of gland, as shown below. Plug the Ethernet cables to the GbE receptacles (OUT: goes to radio and IN: goes to customer network). Listen for a “click” when inserting. This verifies that the jack has been inserted properly. 3 Perform the following actions: Insert the claw to body taking in consideration the caution below (A).
Appendix A - Installing Power Injectors PONE-OD67-AC, Continued Procedure, continued Step Action 4 Perform the following actions: Insert the claw to body taking in consideration the caution below (A). Insert the seal to claw (B). Use the adjustable torque U-wrench to screw the sealing nut to body (C). Do not over tighten. Adjust the tool for maximum tightening torque 6 Nm. Take care when you unplug the RJ-45 jack.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 PONE-OD67-AC, Continued Procedure, continued Step 5 Action Install the grounding cable as shown below. Do not over tighten. Adjust the tool with M5 deep socket for maximum tightening torque 3 Nm. 6 Install the power cable as shown below. 7 For wall installation perform the following actions: Position the device on the wall surface and using a pencil mark the drill points.
Appendix A - Installing Power Injectors PONE-OD-DC Introduction Apply this procedure for installing the outdoor DC power injector PONEOD-DC. Power injector details Characteristics: DC PONE injector Outdoor 60 watt Wall mount Operating temperature -33 C to +55 C DC voltage (V DC) Input nominal: 48 Min: 40.5 Max: 57 DC current (A) Input: 1.9 max Output: 1.85 max Packing List: Grounding lug M4 is pre-installed on the unit.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 PONE-OD-DC, Continued Power injector overview # Marking A Gbe IN / OUT Details Gigabit Ethernet 100/1000 Base-T, Electrical (RJ-45).
Appendix A - Installing Power Injectors PONE-OD-DC, Continued Connection diagram between PONE-OD-DC and local DC power source The following diagram shows the connection between local dc power source and PONE-OD-DC using DC power supply cable DC-PWR-CAB-2: Continued on next page 190
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 PONE-OD-DC, Continued Minimum input voltage versus S-FTP cable length When the DC voltage at the input of the PONE is below 41 V for Cat6 cable and 41.7 V for Cat5E then the length of Gigabit Ethernet (S-FTP) cable (Cat5E or Cat6), between radio unit receptacles and PONE receptacle, cannot reach more than 100 meters.
Appendix A - Installing Power Injectors PONE-OD-DC, Continued Precautions Ensure that: the Safety Precautions on page 17 are applied. Prerequisites Prepare and terminate the following cables: ETH cable as described in Ethernet (S-FTP). Grounding cable as described in Grounding. Power supply cable as described in Power. Tools and materials Tools Adjustable torque wrench tool with TORX bit and screwdrivers (refer to Equipment installation tools) and drill machine (refer to Specific works).
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 PONE-OD-DC, Continued Procedure How to install the PONE-OD-DC onto the pole or wall, proceed as follows: Step 1 Action For pole installation follow this step. For wall installation go to last step. Perform the following actions: Attach the plate onto rear side of PONE, as shown below (A). Install lock washer and screw. Then use the cross headed screwdriver to fully tighten (B).
Appendix A - Installing Power Injectors PONE-OD-DC, Continued Procedure, continued Step 2 Action Perform the following actions for installing the Ethernet (SFTP) cables: Use the tool with TORX T10 bit to remove (A) the clamp screw. Be careful not to drop the screw while removing. Plug (B) the Ethernet cables to the Gbe receptacles (OUT: goes to radio unit and IN: goes to customer network). Listen for a “click” when inserting. This verifies that the jack has been inserted properly.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 PONE-OD-DC, Continued Procedure, continued Step 3 Action Use the tool with TORX T10 bit to install the grounding cable, as shown below. Do not over tighten. Adjust the tool for max tightening torque 0.9 Nm.
Appendix A - Installing Power Injectors PONE-OD-DC, Continued Procedure, continued Step 4 Action Perform the following actions for installing the DC power supply cable onto the PONE INPUT receptacle: Switch-off the: local DC power source & circuit breaker (between PONE and local DC power source). Connect the power cable to the local DC power source (brown wire: +V, blue wire: -V). At the other end of the cable, use a blade to strip the wires of the cable, as shown below.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 PONE-OD-DC, Continued Procedure, continued Step 6 Action For wall installation perform the following actions: Use the tool with TORX T10 bit to remove the six screws (A). Then: Position the device on the wall surface and using a pencil mark the drill points (B). With the drill machine (fitted with 5 mm bit), drill four holes on the wall surface, at a depth of 45 mm.
Appendix A - Installing Power Injectors POE-HP-OD67-DC Introduction Apply this procedure for installing the outdoor DC power injector PONE-HPOD67-DC. Power injector details Characteristics: DC POE injector outdoor-IP67 class 114 watt Wall mount temperature hardened operating temperatures -40° C to +55° C DC voltage (V DC) Input nominal: 48 Min: 40.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 POE-HP-OD67-DC, Continued Power injector overview # Marking Details Use A GND Grounding point. To connect 16 mm 2 grounding cable. B AC-IN 2-pins DC receptacle. To connect DC power supply cable with connector. C Gbe OUT Gigabit Ethernet 10/100/1000 Base T, Electrical (RJ-45).
Appendix A - Installing Power Injectors POE-HP-OD67-DC, Continued Connection diagram between POEHP-OD67-DC and local DC power source The following diagram shows the connection between POE-HP-OD67-DC and local DC power source, using DC-PWR-CAB-1 or DC-PWR-CAB-3 cables: Continued on next page 200
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 POE-HP-OD67-DC, Continued Precautions Ensure that: the Safety Precautions on page 17 are applied. Prerequisites Prepare and terminate the following cables: ETH cable as described in Ethernet (S-FTP). Grounding cable as described in Grounding. Power supply cable as described in Power.
Appendix A - Installing Power Injectors (Page intentionally left blank) 202
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.
Appendix B – Terminating Cables Ethernet (S-FTP) Introduction Apply this procedure for terminating the ETH-CAB-SFTP cable to ST-RJ45 connector. Termination overview The equipment to which you connect the cable requires a different way of cable termination.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 Ethernet (S-FTP), Continued Tools and materials Procedure Tools Blade, cable cutter, plier (long nose) and CRIMP-TOOL-S (refer to Termination of cables). Materials ETH-CAB-SFTP and ST-RJ45.
Appendix B – Terminating Cables Ethernet (S-FTP), Continued Procedure, continued Step Action 2 Untwist wire pairs and arrange according to the T-568 standard straight-through cable, as shown below: 3 Carefully insert the eight wires into the cavity of the wire guide so that its numbering is visible from the top. 4 Measure 16 mm from the jacket’s end and cut all wires protruding from the guide.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 Ethernet (S-FTP), Continued Procedure, continued Step 5 Action Perform the following: Fold back the crimping terminal of the connector. Fully insert wire guide and cable into the connector’s body until the shield (overlapping the jacket’s end) reaches the crimping position. For termination type A: For termination type B: 6 Terminate the wires onto the RJ-45 jack using the tool CRIMPTOOL-S.
Appendix B – Terminating Cables Ethernet (S-FTP), Continued Procedure, continued Step 7 Action With the pliers, bring the terminal of the connector back, over the exposed shield, and press gently around the terminal to form. This will achieve good contact with the shield. For termination type A: For termination type B: 8 Use the Ethernet cable tester to verify the proper cable termination. End of procedure.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.
Appendix B – Terminating Cables Grounding, Continued Tools and materials Procedure Tools Blade, cable cutter, crimping tool for 6 mm2 and 16 mm2 grounding cable and hot air gun (refer to Termination of cables). Materials GND-KIT16-OD (16 mm2 cable) GND-CAB6-ID (6 mm2 cable) How to terminate the 16 mm2 grounding cable to GND-KIT16-OD lugs, proceed as follows: Step Action 1 Cut the grounding cable according to the distance between equipment and grounding bar.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 Grounding, Continued How to terminate the 6 mm2 grounding cable to the attached lug of PONEOD-DC, proceed as follows: Step Action 1 Cut the grounding cable according to the distance between equipment and grounding bar.
Appendix B – Terminating Cables Power Introduction Apply this procedure for terminating the following power supply cables: AC cable for PONE-OD67-AC: AC-PWR-CAB (3 x 0.75 mm2) DC cables for POE-HP-OD67-DC: DC-PWR-CAB-1 (2 x 1 mm2) DC-PWR-CAB-3 (2 x 2.5 mm2) For DC cable termination ((DC-PWR-CAB-2 (2 x 2.5 mm2)) of PONEOD-DC refer to Procedure on page 193.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 Power, Continued Procedure How to terminate the 3 x 0.75 mm2 AC power supply cable to PONE-OD67AC connector, proceed as follows: Step Action 1 Perform the following: Strip approx. 10 mm from the cable’s outer sheath (A). Strip approx. 4 mm from each wire insulation (B). Pass the cable through the parts of gland (C).
Appendix B – Terminating Cables Power, Continued Procedure, continued Step Action 2 Assemble the connector by tightening all parts together, according the order (A) and (B), as shown below: 3 Install the connector, as shown below: 4 Screw the connector and then fully tighten, as shown below: End of procedure.
WiBAS / WiBAS G5 Terminal Stations Installation & Cabling Manual - Edition 2.1 Power, Continued Procedure How to terminate the 2 x 1 mm2 or 2 x 2.5 mm2 DC power supply cable to POE-HP-OD67-DC connector, proceed as follows: Step Action 1 Perform the following: Strip approx. 10 mm from the cable’s outer sheath (A). Strip approx. 4 mm from each wire insulation (B). Pass the cable through the parts of gland (C).
Appendix B – Terminating Cables Power, Continued Procedure, continued Step Action 3 Assemble the connector by tightening all parts together, according the order (A) and (B), as shown below: 4 Install the connector, as shown below: 5 Screw the connector and then fully tighten, as shown below: End of procedure.