StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Document Revision History Revisions • Previous Edition: 2.0 • Current Edition: 2.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Equipment Disposal Disposal of old electrical and electronic equipment (applicable through the European Union and other European countries with separate waste collection systems). This symbol, found on this product and any of its parts or on its operating instructions or on its packaging, indicates that electrical and electronic equipment may not be disposed of as unsorted municipal waste.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Declaration of Conformity Hereby, Intracom S.A. Telecom Solutions declares that the product StreetNode 6250 PTP is CE marked, complying with the requirements of the R&TTE Directive 1999/5/EC , EMC Directive 2004/108/ΕC, LVD Directive 2006/95/ΕC, ΕCO Design Directive 2009/125/EU & with the requirements of the RoHS Directive 2011/65/ΕU. The product complies to all relevant FCC regulations.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Radiation Safety Introduction Any radio equipment is emitting Radio Frequency (RF) radiation through its antenna. In the StreetNodeΤΜ 6250 PTP radio, the antenna is integrated and located inside the unit’s enclosure. It is important to follow any local, national or international regulation during installation and operation of the radio equipment to minimize radiation hazards.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Radiation Safety, Continued General installation guidelines (RF exposure) As a general rule, it is expected that the highest level of emission would be at the antenna emission lobe maximum, in direct line-of-sight condition and in the close vicinity of the antenna.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 FCC Part 15.19 Statement: Information to the User This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Part 15.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Table of Contents Table of Contents .................................................................................................................. 1 1. Introduction ............................................................................................................................3 About this Document ............................................................................................................. 3 2.
(Page intentionally left blank) 2
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 1. Introduction About this Document Scope of document This document is the Installation & Cabling Manual of StreetNodeTM 6250 PTP : Point-to-Point all-outdoor Gigabit Radio 60 GHz. Target Audience This document is addressed to certified technicians with wireless equipment knowledge and skills concerning the following: • • • • Reference manuals Outdoor Radio Unit Installation (Lamp Post or Building Wall).
Chapter 2. Prior to Installation 2.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 List of Materials, Continued Packing list materials The packing list of the radio equipment includes the following items: Order Code SN62-XXXXXX Item Description TM A StreetNode 6250 PTP radio unit with attached mounting plate & safety screw. B Pair of steel hose clamps to fasten the radio unit onto a pole of 60 mm to 114 mm diameter (1). C 4 x screws and upats for wall installation.
Chapter 2. Prior to Installation List of Materials, Continued Powering materials The powering materials consist of the following categories: • Power injectors • Power cables • Power modules & connectors Power injectors The following table shows the power injectors: Item Order Code / Photo A POE-ID-AC75 B POE-IDH-AC56 PoE injector, indoor, temperature hardened, -40°C to +60°C, 90 VAC to 264 VAC, 47 Hz to 63 Hz, 56 W.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 List of Materials, Continued Power cables The following table shows the power cables: Item Order Code / Photo A AC-PWR-CAB B ST-AC-CAB10 Description AC power bulk cable, 3 x 0.75 mm2, 0.6 / 1 kV, stranded, UV-rated, industrial type, for outdoor use (per meter) (1) (for distance between StreetNodeTM 6250 PTP and local power source < 300 m).
Chapter 2. Prior to Installation List of Materials, Continued Power modules & connectors The following table shows the power modules & connectors: All StreetNode 6250 PTP models are provided by the manufacturer with an AC or a DC power module pre-installed on them. However, the power modules can be ordered separately and installed on the radio unit by the customer, if power input modification is required.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 List of Materials, Continued Grounding materials Grounding cables for indoor and outdoor installation are available depending on the installation premises requirements. In each case, two wire gauges are available: • 16mm2 cable is used for units installed on structures where lightning strike is possible (rooftop, telecommunication towers etc.).
Chapter 2.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 List of Materials, Continued S-FTP cables The following table shows the S-FTP cables, accessories and kits: Item Order Code / Photo Description A ETH-CAB-SFTP Ethernet cable S-FTP, 4x2xAWG24, CAT5e, shielded, BLK, UV-rated (per meter). B ST-RJ45 RJ-45 connector, shielded, for S-FTP cable termination. C ETH-HOOD D CRIMP-TOOL-S Hand crimping tool for RJ-45 connector (ST-RJ45 order code).
Chapter 2. Prior to Installation List of Materials, Continued Fiber optic cables The following table shows the fiber optic cables: Order Code / Photo Description FBROPTMM-025 25 m FBROPTMM-50 50 m FBROPTMM-100 FBROPTMM-150 FBROPTMM-200 FBROPTSM-025 FBROPTSM-50 FBROPTSM-100 100 m Prefabricated, connectorized fiber optic cables for outdoor use, DX, 2 x LC / PC – LC / PC, available in Multi Mode (MM) & Single Mode (SM) in different lengths.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 List of Materials, Continued SFP The following table shows the SFPs and gland: Item Order Code / Photo Description A SFP-MM-500M SFP-SM-10KM SFP-SM-40KM SFP-SM-80KM Optical SFP, Multi-Mode, up to 500 m, 1.25 Gbit/s, 850 nm Optical SFP, Single-Mode, up to 10 km, 1.25 Gbit/s, 1310 nm. Optical SFP, Single-Mode, up to 40 km, 1.25 Gbit/s, 1310 nm. Optical SFP, Single-Mode, up to 80 km, 1.25 Gbit/s, 1550 nm.
Chapter 2. Prior to Installation List of Materials, Continued Pole fastening materials The pole fastening materials consist of the following categories: • Mounting bracket • Steel hose clamps • Cable ties Mounting bracket Order Code / Photo Description INST-PONE-PL Mounting bracket and accessories for installation of PONE-OD-DC power injector onto a pole of 50 mm to 120 mm diameter.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 List of Materials, Continued Steel hose clamps Order Code / Photo Description ∅64-140 mm, W=12 mm for ∅60-114 mm pole diameter. (1) ST-CL64-140 Stainless steel hose clamp to fasten the radio unit onto poles or lamp posts. ST-CL102-178 Two hose clamps are needed per radio unit. ST-CL172-248 ∅172-248 mm, W=14 mm for ∅151-234 mm pole diameter. (1) ∅242-318 mm, W=14 mm for ∅235-300 mm pole diameter.
Chapter 2. Prior to Installation Connections StreetNodeTM 6250 PTP (1) The layout and description of the StreetNode 6250 PTP external elements is given below: With DC Power supply module With AC Power supply module # Marking Details Use A GbE2 Ethernet 100/1000Base-T, electrical (RJ-45). Connection of Gigabit Ethernet cable (traffic / inband management / PoE(1) input). B GbE1 Ethernet 100/1000Base-T, electrical (RJ-45). Connection of Gigabit Ethernet cable (traffic / inband management).
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Connections, Continued Outdoor DC PonE The layout and description of the outdoor DC PonE external elements is given below: Item Description Use A Electrical Gigabit interface, RJ-45 (Gbe IN / OUT) Connection of the traffic / power supply / inband management cable. (IN: cable from external Ethernet Switch, OUT: cable to the radio unit).
Chapter 2. Prior to Installation Connections, Continued Outdoor AC PonE The layout and description of the outdoor AC PonE external elements is given below: # Marking Details Use A GbE IN / GbE OUT Ethernet 100/1000Base-T, electrical (RJ-45 with gland) • OUT: Connection of the Gigabit Ethernet S-FTP cable carrying payload traffic, inband management and superimposed DC power towards radio unit.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Connections, Continued Indoor AC PoE The layout and description of the indoor AC PoE external elements is given below: Item Description Use A Electrical Gigabit interface, RJ-45 (Gbe IN / OUT) Connection of the traffic / power supply / inband management cable. (IN: cable from external Ethernet Switch, OUT: cable to the radio unit). B Multi-functioning LED (Green / Red). Providing system indications during operation.
Chapter 2. Prior to Installation Equipment Anchor Points Anchor point The upper 20 mm hole located on the safety bracket on the side (see below) serves as the StreetNodeTM 6250 PTP anchor point. This point can be used to install an appropriate safety lanyard (1). (1) For suggesting anchoring material contact Intracom S.A Telecom Solutions.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Safety Precautions GENERAL • Do not install or operate this system in the presence of flammable gases or fumes. Operating any electrical instrument in such an environment is a safety hazard. • Only trained, authorized personnel should have access to the installed equipment.
Chapter 2. Prior to Installation Safety Precautions, Continued • LOCAL POWER AC SOURCE • Safety requirements require a single pole circuit-breaker to be employed between the local power AC source and StreetNodeTM 6250 PTP (for AC direct powering) or AC power injector. • The circuit breaker must disconnect the mains phase of the AC power.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Safety Precautions, Continued GROUNDING Never power on any equipment (except indoor AC PoE) unless you have completed the grounding installation as described in this manual. There is risk of equipment failure and / or electrical shock. 1 Power Injectors devices PROPER CONNECTION Never connect the power injectors OUT receptacle to network switches / routers / laptops.
Chapter 2. Prior to Installation Site Prerequisites Introduction This paragraph describes all the prerequisites that must be considered prior to installing the equipment. Site survey Site survey should be done before start the installation taking in consideration the following: Premises information • Site details (address, contact persons, GPS and/or map co-ordinates, etc.) • Site access and storage information (means of transport, equipment storage and lifting information, etc.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Site Prerequisites, Continued Preparation of the installation premises Access to the installation premises must be facilitated during the installation period. Entrances must be large enough to enable the easy transportation of the new equipment. The floor must be level, smooth and able to bear the load of the equipment. The roof must be engineered to bear the weight of the service personnel and the outdoor equipment.
Chapter 2. Prior to Installation Site Prerequisites, Continued Wall installation All power injectors offered by Intracom Telecom can be installed as desktop or on a wall surface, as shown below: • Indoor AC PoE: Materials for wall mount installation are not included on the packing list of the product ((requires wood plugs (5 mm X 25 mm) and wood screws cross-headed (4 mm x 30 mm)). • Outdoor DC PonE: Installed as described on Installation of Power Injector (Power over Ethernet) on page 60.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Site Prerequisites, Continued Grounding Ensure the following: • To make a protective earth connection, use the grounding point located on the radio unit using an, as short as possible, length of grounding cable of at least 6mm2 diameter (recommended 16mm2) or according to local electrical code. • A grounding bar is required close to each equipment installation position.
Chapter 2. Prior to Installation Site Prerequisites, Continued Power supply source For the installation location, we assume the existence of an appropriate power supply source with the following specifications: StreetNodeTM 6250 PTP with DC power supply module: -40.5 V dc to -60 V dc. StreetNodeTM 6250 PTP with AC Power Supply Module: 90-240 V / 50 Hz to 60 Hz (Live / Neutral). For applicable input voltage ranges for power injectors please refer to Power injectors on page 6.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Site Prerequisites, Continued Line Of Sight (LOS) verification Prior to installation, the installer must verify LOS availability between the two StreetNodeTM 6250 PTP. Default antenna beam The orientation of the StreetNodeTM 6250 PTP antenna is not critical as node has self-alignment capabilities with tilt range 300 (±150) and elevation range 200 (±100).
Chapter 2. Prior to Installation Site Prerequisites, Continued Lightning & Surge protection In case additional protection against lightning is required for the radio the following should be applied: a. For Ethernet (S-FTP) Cables: Lighting surge protection device (LSP) is required to minimize equipment damage from lighting induced surges. b.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Site Prerequisites, Continued Internal ovp (2) AC Mains Line (StreetNodeTM 6250 PTP) AC power supply module Input Overvoltage Protection: • Live – Neutral: 1 kV – 1.2/50 μs (8/20 μs) • Live – Earth: 2 kV – 1.2/50 μs (8/20 μs) • Neutral – Earth: 2 kV – 1.2/50 μs (8/20 μs) Input Overcurrent Protection: • Double-pole fused through 2 A time-lag fuses (potted, nonreplaceable).
Chapter 2. Prior to Installation Site Prerequisites, Continued Safety Ensure the following: • Only trained, authorized personnel should have access to the installed equipment. • Appropriate labeling should exist at points with high risk of contact with hazardous voltage. • A list with emergency phone numbers (e.g. medical assistance numbers) should be hung at easy-to-view positions.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Cable Length Restrictions Introduction Three types of cables can be connected to StreetNodeTM 6250 PTP interfaces as follows: • Gigabit Ethernet (S-FTP) Cable (Cat 5E or Cat 6) • Fiber Optic Cable (Single mode or Multimode) • Power Supply Cable (AC or DC).
Chapter 2.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Cable Length Restrictions, Continued Cable length restrictions, continued B): Maximum length of cables used for Powering: Due to voltage drop along the length of the powering cable and the minimum voltage requirements at the input of the radio power supply, restrictions apply on the length of powering cables as follows: • Direct DC powering cables: The maximum cable length of the recommended 2 x 1 mm2 cable is 100 m.
Chapter 2. Prior to Installation Cable Length Restrictions, Continued Cable length restrictions, continued • S-FTP cable (CAT5E or CAT6) used with provided power injectors (1) , continued S-FTP cable (CAT5E or CAT6) used with provided DC type power injectors (with order code PONE-OD-DC): The length of the SFTP cable, between PonE injector and radio unit, cannot reach 100 meters when the DC voltage at the input of the PonE is the lowest defined by the standards (40.5 V).
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Antenna Hydrophobic Coating Protection Instruction The polycarbonate cover in front of the antenna is covered by "Cytonix Fluorothane™ -AD super-hydrophobic air drying polymer system" in order to minimize the effects on antenna performance by heavy rain, snow fall and protect against ice accumulation. Fluorothane™ AD will repel water, snow, ice and many aqueous liquids or suspensions.
Chapter 2. Prior to Installation Recommended Tools Topics This paragraph describes the following tools that will be needed: • • • • Equipment installation tools. Ethernet cable termination tools. Power supply cable termination tools. Grounding cable termination tools. The tools are not supplied and are installer responsibility to be available during installation.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Recommended Tools, Continued Ethernet cable termination tools Item Tool/ Photo Description 7 Blade 8 Cable cutter. 9 Pliers (long nose). 10 Crimping tool for terminating S-FTP cable to RJ-45 jacks. 11 Ethernet cable tester.
Chapter 2. Prior to Installation Recommended Tools, Continued Power supply cable termination tools Grounding cable termination tools 40 Item Tool/ Photo Description 12 Soldering iron. 13 Solder. Item Tool/ Photo Description 14 Crimping tool for ring terminals (16 mm and 6 mm). 15 Hot Air Gun.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 3. Installation of StreetNode 6250 PTP Mechanical Installation & Grounding Precautions Before start any installation action please follow the instructions for Antenna Hydrophobic Coating Protection on page 37. Never leave unoccupied receptacles without cover. Covering receptacles is necessary to protect against humidity penetration.
Chapter 3. Installation of StreetNode 6250 PTP Mechanical Installation & Grounding, Continued Lamp post (or pole) installation procedure To install StreetNodeTM 6250 PTP on a lamp post (or pole) , proceed as follows: Step 1 Action Perform the following: a. Using the electrical screwdriver, extension and 3 mm bit, unscrew the safety screw and lock washer (supplied) into the intended hole on the safety plate at the side. b.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Mechanical Installation & Grounding, Continued Lamp post (or pole) installation procedure, continued Step Action 2 Install the two supplied hose clamps onto the mounting plate, as shown below: 3 Using the electrical screwdriver, extension and 7 mm bit, install the mounting plate with clamps onto the pole.
Chapter 3. Installation of StreetNode 6250 PTP Mechanical Installation & Grounding, Continued Lamp post (or pole) installation procedure, continued Step Action 4 Prior to the elevation and installation on the lamp post (or pole), use the anchor point (see arrow below) to install an appropriate safety lanyard.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Mechanical Installation & Grounding, Continued Lamp post (or pole) installation procedure, continued Step 6 Action Perform the following: a. Using the electrical screwdriver, extension and 8 mm bit, tighten the four screws. b. Using the electrical screwdriver, extension and 3 mm bit, tighten the safety screw and lock washer (supplied) into the intended hole on the mounting plate at the side. Do not over tighten screws.
Chapter 3. Installation of StreetNode 6250 PTP Mechanical Installation & Grounding, Continued Building wall installation procedure To install StreetNodeTM 6250 PTP onto building wall surface, proceed as follows: Step 1 Action Perform the following: a. Using the electrical screwdriver, extension and 3 mm bit, unscrew the safety screw and lock washer (supplied) into the intended hole on the safety plate at the side. b. Using the electrical screwdriver, extension and 8 mm bit, loosen the four screws.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Mechanical Installation & Grounding, Continued Building Wall installation procedure, continued Step Action 2 Beware of the correct positioning of the mounting plate, as shown below: • Narrow side up • Wide side down A StreetNodeTM 6250 PTP node must have Line Of Sight (LOS) with the far-end StreetNodeTM 6250 PTP.
Chapter 3. Installation of StreetNode 6250 PTP Mechanical Installation & Grounding, Continued Building Wall installation procedure, continued Step 3 Action Perform the following, as shown below: a. With the drill machine (fitted with 8 mm bit), drill four holes on the wall surface, at a depth of 55 mm. b. Install the four supplied wall plugs. c. Using the four screws and lock washers, install the mounting plate onto the wall. d.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Mechanical Installation & Grounding, Continued Building Wall installation procedure, continued Step Action 4 Prior to the elevation and installation on the wall, use the anchor point (see arrow below) to install an appropriate safety lanyard. 5 Insert the StreetNodeTM 6250 PTP through the intended mounting plate openings and then slide downwards, as shown below: Ensure that StreetNodeTM 6250 PTP is fully seated in the mounting plate.
Chapter 3. Installation of StreetNode 6250 PTP Mechanical Installation & Grounding, Continued Building Wall installation procedure, continued Step 6 Action Perform the following: a. Use the spanner 8 mm for fastening StreetNodeTM 6250 PTP onto the mounting plate. Do not over tighten screws. Adjust the spanner for tightening of M5 screws. b.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Mechanical Installation & Grounding, Continued Grounding cable installation procedure Step Action 1 Prepare and terminate the grounding cable as instructed in Appendix C: Terminating Grounding cable on page 76. 2 Use the electrical screwdriver with extension and 8 mm bit, to remove the M5 screw and one grover. Install the cable and then insert the grover and nut, as shown below.
Chapter 3. Installation of StreetNode 6250 PTP Installation of Traffic Cable(s) Topics This paragraph describes the following procedures of StreetNodeTM 6250 PTP: • Ethernet (S-FTP) cable installation (GbE1 – GbE2 Inputs). • Ethernet (S-FTP) cable installation (SFP Input). Either Optical SFP with fiber optic cable OR electrical SFP with Ethernet (S-FTP) cable is used the installation procedure is identical.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Installation of Traffic Cable(s), Continued Ethernet (S-FTP) cable installation procedure To install StreetNodeTM 6250 PTP Ethernet S-FTP cable, proceed as follows: Step Action 1 Slide all three parts of the supplied gland over the S-FTP cable (StreetNodeTM 6250 PTP side), as shown below: 2 Prepare and terminate the Ethernet cable as instructed in Appendix A: Terminating Ethernet (S-FTP) Cable on page 67.
Chapter 3. Installation of StreetNode 6250 PTP Installation of Traffic Cable(s), Continued Ethernet (S-FTP) cable installation with SFP To install StreetNodeTM 6250 PTP SFP Ethernet (S-FTP) cable with SFP, proceed as follows: Step 1 Action Prepare and terminate the Ethernet cable as instructed in Appendix A: Terminating Ethernet (S-FTP) Cable on page 67.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.
Chapter 3. Installation of StreetNode 6250 PTP Installation of Traffic Cable(s), Continued Ethernet (S-FTP) cable installation with SFP, continued Step 4 Action Push the SFP HOOD flaps to open and then push upwards till the HOOD locked properly.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Installation of Traffic Cable(s), Continued Ethernet (S-FTP) cable installation with SFP, continued Step 5 Action Perform actions (a) and (b – using spanner R.28), as shown below: End of procedure.
Chapter 3. Installation of StreetNode 6250 PTP Installation of Power Cable (Direct Powering) Topics This paragraph describes the following procedure of StreetNodeTM 6250 PTP: • Power supply cable installation (direct powering - StreetNodeTM 6250 PTP side) Tools and materials # Prefabricated Cable Bulk Cable Materials Items B or D from Power cables on page 7. • Items A or C from Power cables on page 7. • Items A or C from Power modules & connectors on page 8.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Installation of Power Cable (Direct Powering), Continued Procedure To install the power supply cable in StreetNodeTM 6250 PTP power input, proceed as follows: Step Action 1 Prepare and terminate the power supply cable as instructed in Appendix B: Terminating Power Supply Cable on page 75. 2 Perform the following actions, as shown below: End of procedure.
Chapter 3. Installation of StreetNode 6250 PTP Installation of Power Injector (Power over Ethernet) Introduction StreetNodeTM 6250 PTP can be powered by either direct powering or Power injector. The power injector can be either PonE (DC -indoor or outdoor) or PoE (AC – outdoor only). PonE: • The power at the input of PonE box must be measured in the range of –40 V dc to –60 V dc.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Installation of Power Injector (Power over Ethernet), Continued Topics This paragraph describes the following procedure of Power Injectors: • Mechanical and Cabling Installation (PonE) • Cabling Installation (PoE) Tools and materials # PonE Materials Lamp post: • Item C from Power injectors on page 6. • Item E from Power cables on page 7. • Item B or C from Grounding materials on page 9.
Chapter 3. Installation of StreetNode 6250 PTP Installation of Power Injector (Power over Ethernet), Continued Mechanical and cabling installation (PonE) For mechanical installation and cabling of PonE, proceed as follows: Step 1 Action Pole installation: a. Attach the plate onto rear side of PonE, as shown below: b. Install grover and screw and using the PH-2 screwdriver fully tighten: c. Pass the hose clamp through the plate holes. d.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Installation of Power Injector (Power over Ethernet), Continued Mechanical and cabling installation (PonE), continued Step Action 2 Prepare and terminate the Ethernet cables (x 2) as instructed in Appendix A: Terminating Ethernet (S-FTP) Cable on page 67. Install the Ethernet cables, as follows: a. Use a tamper-proof torx screwdriver T10 to remove the screw and release the clamp: Be careful not to drop the screws while removing. b.
Chapter 3. Installation of StreetNode 6250 PTP Installation of Power Injector (Power over Ethernet), Continued Mechanical and cabling installation (PonE), continued Step 3 Action Prepare and terminate the grounding cable as instructed in Appendix C: Terminating Grounding cable on page 76. Install the grounding cable, as follows: Use a tamper-proof torx screwdriver T10 to remove the screw and then install the terminal ring.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Installation of Power Injector (Power over Ethernet), Continued Mechanical and cabling installation (PonE), continued Step 4 Action Install the power supply cable, as follows: Switch-off the Local DC Power Source & the circuit breaker connected between PonE and the Local DC Power Source. a. Connect the power cable to the Local DC Power Source (Brown wire: +V, blue wire: -V). b.
Chapter 3. Installation of StreetNode 6250 PTP Installation of Power Injector (Power over Ethernet), Continued Cabling installation (PoE) To install Ethernet and power cables , proceed as follows: Step Action 1 Prepare and terminate the Ethernet cables (x 2) as instructed in Appendix A: Terminating Ethernet (S-FTP) Cable on page 67. 2 Connect the receptacle OUT of the PoE to the GbE2 receptacle of the StreetNodeTM 6250 PTP. Connect the receptacle IN of the PoE to the network switch.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Appendix A: Terminating Ethernet (S-FTP) Cable Introduction The equipment to which you connect the cable requires a different way of cable termination. Mainly there are two types of cable termination, as shown below: #Termination Type Equipment to Connect Detail No shield wires exposed All, except PonE. A Shield wires (twisted) exposed PonE only.
Appendix A: Terminating Ethernet (S-FTP) Cable Appendix A: Terminating S-FTP Cable, Continued Termination procedure Step Action 1 a. For termination type A: Strip 40 mm of outer jacket. For termination type B: Strip 80 mm of outer jacket. b. Fold shield back (over the jacket). c. For termination type A: Twist shield wires together and allow 10 mm of shield to surround jacket’s end. For termination type B: Twist shield wires together and allow 20 mm of shield to surround jacket’s end. d.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Appendix A: Terminating S-FTP Cable, Continued Termination procedure, continued 2 Untwist wire pairs and arrange according to the T-568 standard. Straight-through cable (concerns the Ethernet cable connected to PoE’s IN or StreetNode’s traffic input port): Cross-over cable (concerns the Ethernet cable connecting PoE with the OSDR): (The green set of wires should be switched in place with the orange set of wires.
Appendix A: Terminating Ethernet (S-FTP) Cable Appendix A: Terminating S-FTP Cable, Continued Termination procedure (continued) Step Action 3 Carefully insert the eight wires into the cavity of the wire guide so that its numbering is visible from the top. 4 Measure 16 mm from the jacket’s end and cut all wires protruding from the guide.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Appendix A: Terminating S-FTP Cable, Continued Termination procedure, continued Step Action 5 a. Fold back the crimping terminal of the connector. b. Fully insert wire guide and cable into the connector’s body until the shield (overlapping the jacket’s end) reaches the crimping position.
Appendix A: Terminating Ethernet (S-FTP) Cable Appendix A: Terminating S-FTP Cable, Continued Termination procedure, continued Step 6 Action Terminate the wires onto the RJ-45 jack.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Appendix A: Terminating S-FTP Cable, Continued Termination procedure (continued) Step Action 7 With the pliers, bring the terminal of the connector back, over the exposed shield, and press gently around the terminal to form. This will achieve good contact with the shield.
Appendix A: Terminating Ethernet (S-FTP) Cable Appendix A: Terminating S-FTP Cable, Continued Termination procedure (continued) Step Action 8 With a wire cutter, trim away any braid leftovers extending beyond the end of the plug. When finished, termination should look as below: For termination type A: For termination type B: 9 Using the Ethernet tester, test cable for proper wire termination and continuity. End of procedure.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Appendix B: Terminating Power Supply Cable Procedure To terminate the power supply cable (AC or DC ) to the respective connector (1) of StreetNodeTM 6250 PTP, proceed as follows: Step Action 1 Strip approx. 10 mm from the cable’s outer sheath. 2 Pass the connector parts a, b and c over the cable’s end, as shown below: 3 Strip approx. 4 mm from each wire insulation and solder to the pins of connector part d.
Appendix C: Terminating Grounding cable Appendix C: Terminating Grounding cable Topics This paragraph describes the following procedures of grounding cable termination: • StreetNodeTM 6250 PTP • PonE StreetNodeTM 6250 PTP How to terminate the grounding cable of StreetNodeTM 6250 PTP, proceed as follows: Step Action (1) 1 Cut the grounding cable according to the distance between StreetNodeTM 6250 PTP and grounding bar. 2 Use the blade to strip 1 cm from each end of the cable.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Appendix C: Terminating Grounding cable, Continued How to terminate the grounding cable of StreetNodeTM 6250 PTP, proceed as follows: Step Action 1 Cut the grounding cable according to the distance between PonE and grounding bar. 2 Use the blade to strip 1 cm from each end of the cable. 1 cm 1 cm ~ ~ PonE 3 4 Perform the following: a.
Appendix D: Removing StreetNode 6250 PTP Appendix D: Removing StreetNode 6250 PTP Procedure To remove a StreetNodeTM 6250 PTP, proceed as follows: Step 1 Action StreetNodeTM Use the 6250 PTP anchor point (see below) to install an appropriate safety lanyard. This will provide extra safety during StreetNodeTM 6250 PTP removal and transportation. 2 a. Disconnect StreetNodeTM 6250 PTP from AC power supply (power supply side). b.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Appendix D: Removing StreetNode 6250 PTP, Continued Procedure (continued) Step Action 3 Using the electrical screwdriver, extension and 8 mm bit, remove the safety screw from the side of the StreetNodeTM 6250 PTP mounting plate. 4 Using the electrical screwdriver, extension and 8 mm bit, loosen the four screws securing StreetNodeTM 6250 PTP on the mounting plate.
Appendix D: Removing StreetNode 6250 PTP Appendix D: Removing StreetNode 6250 PTP, Continued Procedure (continued) Step 5 Action Lift and extract StreetNodeTM 6250 PTP. You can now safely transport StreetNodeTM 6250 PTP to ground level. End of procedure.
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.1 Appendix E: Standards of Compliance This product is in full compliance with the following standards: Radio/Use of Spectrum: ETSI EN 302217-3 ν2.2.1 : 2014 ETSI EN 302217-4-2 v1.5.1 : 2010 (antenna) FCC Part 15.255 EMC / EMI : ETSI EN 301 489-1 v1.9.2: 2011 EΤSI ΕN 301 489-4 ν2.1.1 : 2012 EΝ 55022:2010 EΝ 61000.
Appendix E: Standards of Compliance (Page intentionally left blank) 82
StreetNode™ 6250 PTP Installation & Cabling Manual - Edition 2.
(Page intentionally left blank) 84