Getting Started Guide P/N x-xxxx49-01 Sabre 1555 Laser Scanner & RFID Reader/Programmer Guía de Iniciación Guida Introduttiva Guide de Démarrage Guia de Iniciação Anleitung für Einsteiger
Introduction Use this Getting Started Guide to set up the Sabre 1555 laser scanner and RFID reader/ programmer for most terminal connections and symbologies. If necessary, use the EasySet setup software or Installation Manual for additional configuration possibilities and terminal connections.
Connect scanner cable (standard version shown) Scanner cable depends on your terminal Cables Accessories 3
RFID reader/programmer operation "beep" RFID reader/programmer reading distance Sabre 1555 2450 MHz 1 cm - 60 cm (0.4" - 24") Sabre 1555 915 MHz 4 2.
Scanner operation "beep" Scanner reading distance Sabre 1555 Standard Range 6 cm - 34 cm (2.5" - 13.
RS-232 C Ê System power OFF Ë Connect cable Direct RS-232 C cable P/N 3-604032-00 Ì Scanner power ON Í System power ON Î Select standard RS-232 C (PC serial port compatible) 9600 baud, 7 data bits, even parity, 2 stop bits postamble = carriage return + line feed 6
Ï Customize parameters (optional) (*) = default value 9600 baud (*) 19200 baud 7 data bits (*) 8 data bits Even parity (*) Odd parity No parity Postamble = Carriage Return + Line Feed (*) Postamble = Carriage Return Postamble = none 7
RS-232 TTL Ê System power OFF Ë Connect cable Ì Scanner power ON Í System power ON Î Select RS-232 TTL Direct RS-232 TTL cable P/N x-xxxxxx-xx 9600 baud, 7 data bits, even parity, 2 stop bits postamble = carriage return + line feed 8
Ï Customize parameters (optional) (*) = default value 9600 baud (*) 19200 baud 7 data bits (*) 8 data bits Even parity (*) Odd parity No parity Postamble = Carriage Return + Line Feed (*) Postamble = Carriage Return Postamble = none 9
Universal Serial Bus (USB) Ê System power OFF Ë Connect cable Direct USB cable P/N x-xxxxxx-xx Ì Scanner power ON Í System power ON Î Select standard USB (PC serial port compatible) 9600 baud, 7 data bits, even parity, 2 stop bits postamble = carriage return + line feed 10
Ï Customize parameters (optional) (*) = default value Intermec representative needs to supply USB symbologies when the symbols are available.
Symbology Ê Disable all symbologies Ë Select symbology Code 39 UPC-A, UPC-E, EAN-8, EAN-13 (UPC-A -> EAN-13) Code 128 / EAN 128 Ì UPC-A, UPC-E, EAN-8, EAN-13 (UPC-A -> UPC-A) Test Code 39 UPC-A CODE-39 Code 128 CODE-128 EAN 13 1234567890128 12
Reset Online setup Ê Ë System power OFF Connect RS-232 C cable (P/N 3-604032-00) Ì Scanner power ON Í System power ON Î Scan EasySet setup code EasySet Ï Start EasySet software 13
Laser warnings The Sabre 1555 has a maximum laser output of 1mW at 630-680 nm and complies with the following safety standards: USA: CDRH - Class II Laser Product (CFR 21 Subpart J) IEC 825-1 EN 60825-1 - Class 2 Laser Product Fix these warning labels onto the product if they are not already present. Collez les étiquettes d’avertissement sur votre produit. Cole as etiquetas de precaução no equipamento. Bringen Sie Warnetiketten auf dem Produkt an.
Regulatory statements USA & Canada: This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. This device requires a radio license, unless it is used totally inside of a building. (The user must obtain this license.) Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Cet appareil exige une license radio à moins d’être entièrement installé dans un bâtiment.