Multi-Wave PE653-PE953 Installation Guide Important Safety Instructions All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: DANGER: To reduce the risk of injury, do not remove the suction fittings of your spa or hot tub. Never operate a spa or hot tub if the suction fittings are broken or missing.
Safety 3 • Children should not use spas or hot tubs without adult supervision. • Do not use spas or hot tubs unless all suction guards are installed to prevent body and hair entrapment. • People using medications and/or having an adverse medical history should consult a physician before using a spa or hot tub. • People with infectious diseases should not use a spa or hot tub. • To avoid injury, exercise care when entering or exiting the spa or hot tub.
Multi-Wave PE653-PE953 Installation Guide Contents Important Safety Instructions............................................................................................................2 Section 1: System Overview..........................................................................................................8 Additional Detail on Key Components..........................................................................................9 Hand-Held Controller (PE953)............................
Contents 5 Low-Voltage Wiring....................................................................................................................35 Water Temperature Sensor......................................................................................................35 Freeze/Air Temperature Sensor................................................................................................35 Communications to a Variable-Speed Pump .................................................................
Multi-Wave PE653-PE953 Installation Guide Section 6:Advanced Features.......................................................................................................58 Configuring Two or More Hand-Held Controllers...................................................................58 Changing a Secondary Remote Control into a Primary Control...............................................60 Including the PE953 Controller into a non-Multi-Wave (other manufacturer’s) network..........
Notes ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ __________________
Multi-Wave PE653-PE953 Installation Guide Section 1: System Overview The Intermatic Multi-Wave Pool/Spa PE653RC Wireless Control System brings wireless control to a new level of simplicity and affordability. The following features make the system distinctive: • Easy to Use — with simple, push button controls and a clear, easy-to-read display panel • Everything You Need — includes the functionality and control called for in nearly every installation.
One: System Overview 9 Additional Detail on Key Components Hand-Held Controller (PE953) The main function of the Hand-Held Controller is to transmit user commands to the PE653 Receiving Device, PE650 Receiving Device, and/ or Z-Wave home control devices, and to display the status of the installed equipment. TER EN The unit floats if thrown in the pool or spa, is water-submersible, shock resistant, and requires three (3) AA batteries. Expected battery life is about one year in typical use.
Multi-Wave PE653-PE953 Installation Guide 24-Volt Valve/Pump Switch (P4243ME) Designed as part of the Multi-Wave system and for aftermarket and retrofit applications, the P4243ME is most suited for controlling up to two different circuits associated with pool/spa combinations, but can also be used to control all the equipment typically needed in connection with water features, water gardening, solar heating, and other similar applications.
Two: Plumbing and Wiring Examples 11 Section 2: Plumbing Examples The following diagrams show several plumbing and wiring examples of installations for pool and spa that share a single filter pump, filter, and heater. If you are installing a pool only or spa only, these diagrams will not apply. For Pool and Spa Combo Installations For Booster Pump Pool Cleaner Installations Providing a brighter solution.
Multi-Wave PE653-PE953 Installation Guide For Non-Booster Pump Pool Cleaner Installations Pool Spa Return Intake Intake Energy Filter Check Valve Spa Make-up Filter Heater Copyright © 2010 Intermatic, Inc.
Three: PE653 Receiving Device Installation Section 3: Installing and Wiring the PE653 Receiving Device • To avoid fire, shock, or death, turn off power at circuit breaker and test that power is off before wiring. • Read instructions completely before installation and retain for future reference. • Observe all national and local electrical and safety codes. • Disconnect power when servicing or changing loads. • Alterations or modifications to the device will void the warranty.
Multi-Wave PE653-PE953 Installation Guide Wiring Instructions INCLUDE/EXCLUDE switch Power Connections AC POWER & STATUS indicator • 1- Speed Pump: Must be powered from Terminal 3. Manual ON/OFF Switches • 2-Speed Pump: Must be powered from Terminal 3 for High-Speed and Terminal 4 for Low-Speed. • Booster Pump: Must be powered from Terminal 6. • Actuator Control: Must be powered from Terminal 7. • Heater Control: Must be Terminals 8 & 9.
Three: PE653 Receiving Device Installation 15 Upper Terminal Connections Water Sensor (PA122) Solar Sensor (PA122) Air Sensor (178PA28A) Remote Antenna Connector Local Antenna Connector Serial Connection (RS485) NOTE: Observe polarity when connecting pump manufacturer’s cable to the Serial connection. Figure 3-3 PE653 Master Control Center Upper Terminal identification Installation Instructions 1.
Multi-Wave PE653-PE953 Installation Guide List of Wiring Diagrams Variable-Speed Pumps 240V Variable-Speed Pump.......................................................................................................... Figure 3-4 One-Speed Pumps 120V 1-Speed Pump.................................................................................................................... Figure 3- 5 120V 1-Speed pump + any 4 120 VAC auxiliary equipment.........................................................
Three: PE653 Receiving Device Installation Variable-Speed Pumps 240V Variable-Speed Pump Figure 3-4 Providing a brighter solution.
Multi-Wave PE653-PE953 Installation Guide 1-Speed Pumps 120V 1-speed pump Figure 3-5 Copyright © 2010 Intermatic, Inc.
Three: PE653 Receiving Device Installation 120V 1-speed pump + any four 120 VAC auxiliary equipment Figure 3-6 Providing a brighter solution.
Multi-Wave PE653-PE953 Installation Guide 120V 1-speed pump + 120 VAC blower or lights + 120V booster pump + 120V actuator + heater Figure 3-7 Copyright © 2010 Intermatic, Inc.
Three: PE653 Receiving Device Installation 120V 1-speed pump + 120V blower + 120V lights + 120V actuator + heater Figure 3-8 Providing a brighter solution.
Multi-Wave PE653-PE953 Installation Guide 240V Pumps 240V 1-speed pump Figure 3-9 Copyright © 2010 Intermatic, Inc.
Three: PE653 Receiving Device Installation 240V 1-speed pump + any four 240 VAC auxiliary equipment Figure 3-10 Providing a brighter solution.
Multi-Wave PE653-PE953 Installation Guide 240V 1-speed pump + 240V blower + 240V booster pump + 240V actuator + heater Figure 3-11 Copyright © 2010 Intermatic, Inc.
Three: PE653 Receiving Device Installation 240V 1-speed pump + 120V lights + 120V blower + 240V actuator + heater Figure 3-12 Providing a brighter solution.
Multi-Wave PE653-PE953 Installation Guide 240V 2-Speed Pump Figure 3-13 Copyright © 2010 Intermatic, Inc.
Three: PE653 Receiving Device Installation 240V 2-speed pump + any three 240VAC auxiliary equipment Figure 3-14 Providing a brighter solution.
Multi-Wave PE653-PE953 Installation Guide 240V 2-Speed pump + any 3 120 VAC auxiliary equipment Figure 3-15 Copyright © 2010 Intermatic, Inc.