Technical Manual for Master Terminals IF 1525 German Version: 7/2004 English Version: 7/2004 LI-1525
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received including interference that may cause undesired operation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Technical Manual Master Terminals for Access Control as well as Time & Attendance Recording This manual describes the functions of the individual boards, configurations, connections and tests as well as the procedure during installation. Instructions referring to connections and configurations are marked with the symbol #. Please observe these instructions as they guarantee malfunction-free operation of the entire system.
Table of Contents Table of Contents Functional Description .......................................................................................................... 1 Functional Description ................................................................................................................ 1 Master Functions ........................................................................................................................ 2 Connections and Modes of Operation ..............................
Table of Contents Initial Operation ....................................................................................................................26 How to Erase and Initialize the RAM (Cold Boot) .....................................................................27 RESET.......................................................................................................................................27 Configuration of Network Interfaces .........................................................
Technical Manual for Master Terminals of the Series IF 152x
Technical Manual for Master Terminals of the Series IF 152x Functional Description Functional Description The master terminals of the series IF 152x are part of a time and attendance recording system. They are installed close to where employees work and connected directly to the higher-ranking system, e.g. to a PC or a router by means of a data line. These master terminals have been designed to record time data such as work time begin, work time end, cost center data as well as change of cost center.
Technical Manual for Master Terminals of the Series IF 152x Master Functions Depending on the hardware equipment, the master terminal is capable of handling the data traffic of IF XXX terminals independently. The required data, such as information on booking-authorized card numbers, day and week programs, keys and display texts, is stored in the RAM. Part of the RAM is used as a ring booking storage. All the bookings and events recorded - also those from the terminals connected - are stored there.
Technical Manual for Master Terminals of the Series IF 152x Functional Units The master terminal is equipped with the following functional units: • Controller Unit (master unit) consisting of the following hardware assembly units: MPU board with CPU IC 68EN302, D-RAM, C-RAM, Flash-RAM, I/O interfaces and an interface to the data entry unit. • Recording Unit (terminal unit) CPU IC 68 HC 12, card reader, display and interface to the controller unit.
Technical Manual for Master Terminals of the Series IF 152x Memory The master terminal IF 1525 is equipped with the following memory: • CMOS-RAM • Flash-PROM • D-RAM CMOS-RAM, 1 MB The check sum of the application software as well as user-specific data, which is loaded via host, is stored in the CMOS-RAM. The CMOS-RAM is power supplied by a lithium battery. Therefore, data is also preserved in case of down time of the main power supply.
Technical Manual for Master Terminals of the Series IF 152x Technical Data Technical data Power supply: - Power consumption 16 VA - Mains voltage 24V AC or DC, +/- 10% - Internal emergency power supply (option) For 0,2 hours Data memory: - Flash-PROM - C-RAM - D-RAM Retention of data in C-RAM Processors: Interfaces: - Interface to host systems 2 MB controller software 1 MB user data 4 MB main memory 8 years (lithium battery) Motorola 68EN302, 25 MHz Motorola 68HC12 Clock IC, crystal-stabilized - Interfa
Technical Manual for Master Terminals of the Series IF 152x Display and Operating Units 1 2 F1 F2 F3 7 4 A F4 ? * # 14: 47 XXXXXXXXXXX B 3 C D 57 5 7 8 9 4 5 6 1 2 3 C 0 E 6 1 Keys for scrolling accounts during info bookings and for forwarding dialog menus during cost center bookings.
Technical Manual for Master Terminals of the Series IF 152x Time Recording Booking 1. Press one of the keys to select the desired booking type. 2. and wait Present the identification medium at a distance of 2 cm in front of the pictogram until the master terminal acknowledges the action with a short ‘beep’ and by displaying the user account.
Technical Manual for Master Terminals of the Series IF 152x Master Terminals for Time Recording Master terminals of the series IF 152x are mainly used for time recording. Time Recording The application depends on the software features of the time/access program and also on the parameter settings.
Technical Manual for Master Terminals of the Series IF 152x Terminal Equipment The master terminals are equipped as follows: • Proximity reader. • Data interface to higher-ranking system (host computer, router) Ethernet 10 BASE T network connection Master terminals are equipped with an Ethernet 10 Base T interface. Data is transferred exclusively with the TCP/IP data protocol. • RAM CMOS-RAM (battery buffered) • D-RAM • Flash-PROM The Flash-PROM is used as program memory for the controller software.
Technical Manual for Master Terminals of the Series IF 152x Block Diagram and Assembly Unit Overview The following graph shows the functional units of the electronic boards with MPU main board 02-0448 A. Back panel of housing Front panel of housing A B ADDRESS LOGIC RS 485 2 SW RS 485 SH Br. + KEY LOW-VOLTAGE POWER SUPPLY J6 KEYBOARD LOGIC Br.
Technical Manual for Master Terminals of the Series IF 152x View on the Input Side of Terminal and Electrical Components 4 5 3 9 8 J3 IC 68 HC 12 2 J1 KL. 1 7 1 2b OFF ON 1 2 2a 2b LED OFF RUN RTS KALTST 2a ON 6 + BAT Housing MPU main board 02-0448 RESET switch Lithium battery 8a 3 4 5 6 Proximity reader board Display Housing back In/output connector board 7 8 8a 9 152x.
Technical Manual for Master Terminals of the Series IF 152x MPU main board 02-0448 index A (with J 16 connector and Br.
Technical Manual for Master Terminals of the Series IF 152x Connector Board The connector board is necessary for the connection of: • Low voltage • Emergency power board 1c 1b 1 circuit 1+ 6 7 Br.1 A Br.1 B Br.1A BAT +TxD - TxD Br.6 J1 J3 Br.1B 2- Br.7 J6 Br.8 J2 1a Br.6 1 2 3 4 5 6 7 3 KL. 1 4 5 Br.9 Br.10 J5 J7 terminal strip Kl. 1 Br.7 Br.
Technical Manual for Master Terminals of the Series IF 152x Emergency Power Board (Option) This board assures continuity of function in case of primary power supply failure. Note: When mains power fails the terminal sends a message to the host system. Technical data Accumulator: Charging current: Operation time assured: Life of accumulators: 12 V 250 mAh 25 mA (recharge time 24 hours) 4 hours about 5 years in normal environment conditions.
Technical Manual for Master Terminals of the Series IF 152x Input/ Output Connector Board (Optional) The input/ output connector (article no. 02-0128, figure 1) serves as the input for indicator or counting contacts as well as for the activation of electrical control elements and external systems. Relay 1 (Figure 2) Relay 1 is exclusively used for the activation of an electrical access control element.
Technical Manual for Master Terminals of the Series IF 152x Open/ Close Housing The housing consists of two parts: • Front part • Wall part Both parts are connected via guiding mechanism and secured by a mortise lock. # Caution: Switch off the voltage supply before opening the housing ! Open housing: # Open the mortise lock with the key and pull it out. # Push the front part of the housing as far upwards as possible and remove it by pulling it to the front.
Technical Manual for Master Terminals of the Series IF 152x Connection Service PC (Optional) The terminal strip of the Ethernet board integrated serves the connection of a dialog station or a PC with COM interface. Details on the connection are shown in the following graph.
Technical Manual for Master Terminals of the Series IF 152x Installation Specifications Master terminals for time and attendance recording are mounted close to where employees work. To ensure proper installation, we recommend an "on-site inspection" with the future operator of the system and the preparation of an installation plan. The plan should include information on the following: • Mounting location of the master terminal, installation height.
Technical Manual for Master Terminals of the Series IF 152x Fastening The wall part of the housing is fastened to an even surface with three screws. Details on the wall fastening as well as the feeding of the connecting cables for wall/ flush mounting are shown in the graph below. # Select an installation height which makes optimal operation possible for all users. # Use the boring pattern to trace the bore holes. 3 1 4 2 1,150mm 1a 1b 3 223.6 6 6 205.5 4 1 239 5 51.3 6 2 31.
Technical Manual for Master Terminals of the Series IF 152x Connection • All of the connections and settings are to be carried out according to this manual. • Detailed instructions can be found in the respective chapters of this manual. • Connect the cables and external systems required for operation as described to ensure malfunction-free operation. • Switch on the operating voltage and put the master terminal into operation. # Caution: Switch off mains power before connecting the master terminal.
Technical Manual for Master Terminals of the Series IF 152x Connection of Cables Connections on Front Panel and Back Panel front panel back panel J6 4 3 J 12 J3 + J 112 J 106 BAT J1 - J 16 8 2 1 J1 1 Graph: Cable connection on back panel and front panel 1 MPU board (02-0448, index A) 3 2 Connector board 4 Ethernet board Battery charger and accumulator Page 21
Technical Manual for Master Terminals of the Series IF 152x Connection 24 V Mains Power Cable Connect 24 V mains power cable (recommended cable type NYM 3x 1.5 mm) to terminal strip Kl. 1 as follows: + 24V DC/ AC to terminal 1 - 24V DC/ AC to terminal 2 Ground Connection Ethernet Network Cable (10 Base T) Connect Ethernet twisted pair cable to Ethernet connector RJ 45. J6 LED LINK J 21 1a 2 J 20 5 LED RX J 12 + J3 1 2 1 1 2 3 4 5 6 7 Br.1 A Br.
Technical Manual for Master Terminals of the Series IF 152x Connection - Accumulator Cable Procedure: # Insert both accumulator cables in J 1 (1a). # Connect boards from back panel of housing to front panel of housing # Set mains power ON. # Check that LED (behind accumulator 1b) is on. Note: LED shows charge process in progress. Accumulator recharge faulty see chapter “Display and Operating Units”. # Caution: The check is only possible if the operating voltage is switched on and the housing is open.
Technical Manual for Master Terminals of the Series IF 152x Connection of Electric Access Point Actuators (Optional) Closed-circuit or open-circuit control elements for DC or AC operation and a maximum power of 30 V 2 A can be switched with relay 1. The connection and the required settings are shown in the graph below. Connect electric access point actuators (graph, 2) to the input/ output connector board.
Technical Manual for Master Terminals of the Series IF 152x Connection of Surveillance Sensor, Opening Contact/ Handle Contact # Connect the surveillance sensor to the input/ output connector board. Terminal 1 to Terminal 3 to Terminal 4 to # IN 1 signal cable to surveillance sensor GND signal cable to surveillance sensor.
Technical Manual for Master Terminals of the Series IF 152x Initial Operation # Caution: Initial operation is only possible if the operating voltage is switched on and the housing is open. Therefore, only persons that have been instructed in the danger of electricity, based on the rules for the prevention of accidents, are authorized to perform initial operation. Once the initial operation has been carried out, the master terminal is ready for operation.
Technical Manual for Master Terminals of the Series IF 152x How to Erase and Initialize the RAM (Cold Boot) The cold boot erases all the user data, initializes the C-RAM and sets the default values required for operation. All the data must be reloaded.
Technical Manual for Master Terminals of the Series IF 152x Configuration of Network Interfaces The master terminal requires the following data for building up TCP/ IP connections: • Internet address (default factory setting 172.18.70.52). • Port number (default factory setting 2001) • Subnet mask • Routing to host system The data is partly given by the network administrator and must be saved in the Flash-PROM of the MPU by means of a configuration menu during initial operation.
Technical Manual for Master Terminals of the Series IF 152x How to Retrieve Information on Internet Address and Port Number Parameterization With the OC menu $ netpar you can retrieve information on the currently stored network parameters and the Ethernet node number. How to Change and Save the Internet Address and the Port Number Parameterization The IP address and the port number are changed with the OC menu $ netpar -x and stored in the EE-PROM.
Technical Manual for Master Terminals of the Series IF 152x Routing entries of the previous example With subnetworks IF 152x (1) Subnet mask entry required, other input fields all set to 0.0.0.0 IF 152x (2) Subnet mask and routing entries required, preferably peer-to-peer, other input fields all set to 0.0.0.0 Without subnetworks IF 152x (1) No routing entries required, all input fields set to 0.0.0.0 IF 152x (2) Routing entries required, preferably peer-to-peer, other input fields all set to 0.0.0.
Technical Manual for Master Terminals of the Series IF 152x How to Adjust the Display Contrast The contrast of the display can be adjusted with the potentiometer R 46 (MPU board). The contrast is correct and must not be changed if the dots of the characters can be recognized from different points of view. Regardless of a person's size (eye level), the characters are legible. The contrast must only be adjusted if the characters can hardly be recognized from some angles of view (eye level).
Technical Manual for Master Terminals of the Series IF 152x Test The controller software of the master terminal contains a test program (OC task) which can be operated via service interface per dialog station or via network connection with TELNET. The following can serve as a dialog station: • PC with RS 232 interface service cable and terminal emulation program. Detailed information on the connection and the settings can be found in the chapter "Service PC Connection". • PC within a network and TELNET.
Technical Manual for Master Terminals of the Series IF 152x PING With PING, the connection between two network users can be checked. PING is started at a network host or via dialog station, which is connected to the master terminal, by entering the target internet address or the assigned host name (not possible at the master terminal). Once the connection has been built up successfully, the target system acknowledges the inquiry.
Technical Manual for Master Terminals of the Series IF 152x Repair and Maintenance Repair and Exchange Repairs are usually limited to the exchange of the complete master terminal. However, it is also possible to detect the cause of trouble and to exchange the assembly units concerned, especially the interface boards. Please note that the software of the master terminal can also be responsible for malfunctions and that a program update can sometimes eliminate the error.
Technical Manual for Master Terminals of the Series IF 152x Maintenance Preventive maintenance of master terminals is usually not required. How to Replace the Accumulator Block Replace the accumulator block of the internal emergency power supply board after: • 5 years if the master terminal is operated in an environment with an ambient temperature of approx. 20° C. How to Replace the Lithium Battery Replace the lithium battery (38-0002) on the MPU board after 8 years at the latest.
Technical Manual for Master Terminals of the Series IF 152x How to Exchange the Firmware/ Application Software The master terminal requires the following software for operation: • Firmware with terminal functions (terminal firmware) • Controller software (MPU board) consisting of: - Application software - Operating system software - Network software Each software version has its own number which gives information on the respective software release.
6 Index N A O assembly units 10 offline 2 B P booking storage 2 type 1 port number 28 preferred direction 9 C RAM 2, 9 test 27 relay 15 RESET 27 cold boot 27 connection Ethernet cable 23 host computer 2 how to proceed 20 power 230 V cable 23 service computer 17 contact inputs 15 controller unit 3 D data line 2 display contrast 31 E emergency power supply 9 Ethernet node number 29 F function keys 1 fuse 13 H Index network connection 9 numeric keypad 1 R S settings IP address 29 network r