GOPAC Docking Station and Amplifier User Manual M13-0002-00A - REV D.4 Nucomm Inc. 101 Bilby Road Hackettstown, NJ 07840 Tel: 908-852-3700 Fax: 908-813-0399 www.Nucomm.
GoPac CAUTION! RISK OF ELECTRICAL SHOCK. DO NOT REMOVE COVERS. • • • • Do not remove any covers. Refer servicing to qualified technicians only. Disconnect all power before servicing. Read and perform all instructions carefully. Failure to follow suggested instructions and guidelines may void all warranties. FCC STATEMENT This equipment has been tested and found to comply with Part 74.637 (a) (2) of the FCC Rules and Regulations.
GoPac Proprietary & Disclaimer Notice All information and graphic images herein contained within this manual are considered the sole property of Nucomm, Inc. and is issued in the strictest of confidence. This material may not be reproduced, stored, copied, or converted in any form, nor shall it be disclosed to others or used for manufacturing or any other purpose without the written permission of an authorized representative of Nucomm, Inc. Nucomm, Inc.
GoPac Field Service Nucomm products are designed with easy access to components to facilitate service. However, to prevent voiding of the Nucomm warranty that protects the equipment, please contact Nucomm before servicing or making any repairs. When troubleshooting, the user is cautioned to read all module descriptions in this manual. Some Nucomm modules cannot be serviced in the field. Warnings are included in the circuit descriptions and on certain modules themselves.
GoPac Equipment Returns If equipment cannot be successfully restored through telephone consultation, the equipment may be returned to the factory for repair. Loaner equipment is often available until Nucomm is able to return the repaired unit(s). For out-of-warranty equipment only: Nucomm evaluates all returned units, and then confers with the client on corrective action. If no fault is found, or no corrective action is authorized, a diagnostic fee may be charged.
GoPac Table of Contents 1. 2. 3. 4. 5. Description & Features...................................................................................................9 1.1 Description.........................................................................................................9 1.2 Features ..............................................................................................................9 Theory of Operation ...............................................................................
GoPac Document Revision Date Modified April 9, 2007 Revision D.2 Modified by M Hardy Modification Detail Added extra FCC language April 10, 2007 D.3 M Hardy Added RF Exposure warning April 10, 2007 D.4 G Williamson Added minimum allowable distance from antenna table M13-0002-00A Rev D.
GoPac M13-0002-00A Rev D.
GoPac Description& Features POWER OUTPUT 1. DESCRIPTION & FEATURES Typically camera back transmitters are limited to less than 250 mW of output power, limiting their range. For extended range operation, the GoPac docking station/amplifier outputs up to 5W digital (optional up to 8W digital). 1.
GoPac M13-0002-00A Rev D.
GoPac Theory of Operation 2. THEORY OF OPERATION The GoPac Power amplifier has been designed to receive the output from a low power transmitter and amplify it. The following discussion assumes that the external transmitter has output power less than 250mW and has been verified to abide by all FCC rules and regulations. The RF output from the low power transmitter is applied to the RF Input Connector (J1) as shown in Figure 1. The signal is passed through a power coupler (C1).
GoPac Theory of Operation Figure 1: System Block Diagram M13-0002-00A Rev D.
GoPac Specifications 3. SPECIFICATIONS RF Performance Frequency band:......................................................1.99 GHz – 2.70 GHz .................................................................................6.40 GHz – 7.10 GHz Frequency tuning step size:.....................................50 KHz (United States) RF Output Power: ...................................................1 to 5W (digital) standard (8W optional) RF Power Modes Standby: ..............................................
GoPac M13-0002-00A Rev D.
GoPac Installation transmitter, and the RF input of the GoPac. (Figure 3). 4. INSTALLATION 4.1 UNPACKING & INSPECTION Unpack and visually inspect the unit for LCD, connector, and surface area damage. All claims should be filed with the carrier. Save all shipping and packing materials for possible re-use. 4.2 To connect a power source to GoPac: The built-in power supply accepts 90 to 240 VAC (40 to 60 Hz) or +11 VDC to +32 VDC without requiring any jumper or switch settings.
GoPac Installation RF Output (to antenna) Guide pins for mounting camera back transmitter RF Input (from camera back transmitter, e.g.) Figure 2: GoPac Guide Pins & RF Connectors Figure 3: GoPac fitted with RF cables M13-0002-00A Rev D.
GoPac Installation AC & DC breakers Power Input connector Figure 4: Input Power & Breakers location PIN-OUT C E G H, S DESCRIPTION AC Neutral Chassis GND AC Line GND P, U, B +DC IN Nucomm P/N: 512-M2001-000 Detoronics P/N: DT02H-14-18PN Mating Connector Nucomm P/N 512-F3001-000 Mil-C-26482, Series 1 P/N: MS3116F-14-1PS Figure 5: Input Power Connector pinout M13-0002-00A Rev D.
GoPac M13-0002-00A Rev D.
GoPac Installation 5. OPERATION 5.1 CONTROLS AND INDICATORS 5.2 POWER ON / OFF (1) 5.3 RF MODE (2) • STANDBY • LOW • MEDIUM • HIGH 5.4 STATUS LEDS (3) • POWER (GREEN) – Power is on. • TX (GREEN) – Unit is transmitting. • ALARM (RED) – Unit is in alarm. 5.5 POWER UP The CamPac2 is turned on by rotating the POWER switch to the ON position. The unit will boot-up and go immediately to the Normal Screen. 5.
GoPac 5.7 Operation RF SETUP 5.9 All frequency selection is done via the attached input device, typically a camera back portable transmitter. As such, the only RF setting available on the GoPac is the adjustment of the RF Power Output level. 5.8 ALARMS The GoPac “STATUS” display section will detail any errors that may occur in the unit.
GoPac M13-0002-00A Rev D.
GoPac Nucomm Inc. 101 Bilby Road Hackettstown, NJ 07840 Tel: 908-852-3700 Fax: 908-813-0399 www.Nucomm.com M13-0002-00A Rev D.