Mini PTZ Network Fixed Dome Cameras Quick Guide V2.
Waterproof Requirements Please waterproof cables in accordance with the following instructions. User shall assume all responsibility for device damage caused by water due to improper waterproof measures. NOTE! ⚫ Before you start, connect all the needed cables and cut off the copper wires for the cables that you don't use. ⚫ Please use self-adhesive waterproof tape (supplied with some products) to protect the cables. ⚫ Use waterproof components to protect the network cable.
. Install the supplied waterproof components to the network cable in sequence. CAUTION! You need to mount the rubber ring onto the network cable interface first. 4. If your camera has a DC cable and you will not use it, insert the plug into the interface. DC interface Plug 5. (Optional) After the waterproof treatment is completed, put the cables into a waterproof junction box (purchased separately). CAUTION! ⚫ The cable connector must not be exposed and must be kept away from water.
1 Packing List Contact your local dealer if the package is damaged or incomplete. The attachments may vary with models, please see the actual model for details. Item Quantity Camera 1 User document 1 Accessory pack 1 2 Safety and Compliance Information 2.1 Installation ⚫ Make sure the camera operates in an environment where the temperature and humidity meet requirements. Keep the camera from excessive pressure, vibration, moisture, dust, and intensive electromagnetic radiation.
⚫ Contact professionals for maintenance information. Do not attempt to dismantle the device by yourself. We shall not assume any responsibility for problems caused by unauthorized repair or maintenance. 2.2 Maintenance ⚫ Caution: There will be risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. ⚫ If there is dust on the glass window surface, remove the dust gently using an oilfree brush or a rubber dust blowing ball.
∅129.0mm (5.1") 108.5mm ø (4.3") 143.6mm (5.7") 3-ø 4.0mm (0.16") S100.0mm (3.9") 1/4-UNC-2B 3.2 Cable Connection The appearance and tail cable may vary with device model. Third-party device connected through RS485 interface IP Network Power adapter ALM_OUT_P/ALM_OUT_N/ALM_INPUT/GND NOTE! For specifications, see the latest product datasheet. 4 Mount Your Camera 4.1 (Optional) Insert Micro SD Card To use the local storage function, you need to install a Micro SD card into the camera.
Insert the SD card along the arrow direction Open the slot cover 4.2 Ceiling Mount You may adopt ceiling mount or wall mount as needed. Prepare hardware accessories by yourself. The following part takes ceiling mount as an example. Wall mount is similar to ceiling mount and therefore is omitted here. Make sure that the wall is capable of supporting the weight of the camera. 1. Uninstall the adapter plate. Hold the camera, rotate the adapter plate counterclockwise to detach it from the camera.
3. Fix the adapter plate to the ceiling. Knock expansion bolts into holes, and fix the plate to the ceiling with screws. Make sure that FRONT on the plate is in monitoring direction. 4. Install the camera. Secure the camera to the adapter, align FRONT on the plate with the gap between OPEN and LOCK on the camera, rotate the camera counterclockwise until it’s fastened.
NOTE! ⚫ Lead the cable through the side slot opening on the camera to secure the cable, so that you may avoid opening a hole on the ceiling. ⚫ Disconnect from power before intalling or uninstalling Micro SD card. Otherwise, the device or the Micro SD card might be damaged. For recommended SD card specifications, contact your dealer or technical support. 5 Startup Check that the device is properly installed, then connect power to start up the device.
Disclaimer and Safety Warnings Trademark Acknowledgements All other trademarks, products, services and companies in this manual or the product described in this manual are the property of their respective owners.
⚫ Company reserves the right to change any information in this manual without any prior notice or indication. Due to such reasons as product version upgrade or regulatory requirement of relevant regions, this manual will be periodically updated. Disclaimer of Liability ⚫ To the extent allowed by applicable law, in no event will company be liable for any special, incidental, indirect, consequential damages, nor for any loss of profits, data, and documents.
⚫ Enable HTTPS/SSL: Use SSL certificate to encrypt HTTP communications and ensure data security. ⚫ Enable IP address filtering: Allow access only from the specified IP addresses. ⚫ Minimum port mapping: Configure your router or firewall to open a minimum set of ports to the WAN and keep only the necessary port mappings. Never set the device as the DMZ host or configure a full cone NAT.
⚫ Make sure the power supply provides a stable voltage that meets the power requirements of the device. Make sure the power supply's output power exceeds the total maximum power of all the connected devices. ⚫ Verify that the device is properly installed before connecting it to power. ⚫ Do not remove the seal from the device body without consulting company first. Do not attempt to service the product yourself. Contact a trained professional for maintenance.
➢ Chemical Burn Hazard. This product contains a coin cell battery. Do not ingest battery. If the coin cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. ➢ Keep new and used batteries away from children. ➢ If the battery compartment does not close securely, stop using the product and keep it away from children. ➢ If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
The product this manual refers to is covered by the Waste Electrical & Electronic Equipment (WEEE) Directive and must be disposed of in a responsible manner. Battery Directive-2013/56/EC Battery in the product complies with the European Battery Directive 2013/56/EC. For proper recycling, return the battery to your supplier or to a designated collection point.