Install Instructions

IW25-1 Installation Steps & Procedures
Locate an area to install the dehumidifier. Confirm that there are no obstructions Cut a hole in the sheet rock with a utility knife Install 4 screws in mounting flanges,
You need a drain, 110 V power & verify the beyond the wall board like plumbing or ¼” larger than the actual dimensions of the rear securely into the 2x4 wall studs directly
location is suitable for the back of the electric lines. of the dehumidifier. Make Sure the opening is though the sheet rock.
de-humidifier to protrude from the square, plumb and offers bottom support for the
other side of the wall. unit. Opening Dimensions: 14.5”x25.5”x9.38
Securely insert the drain hose into your hub drain. Be certain the drain is below Plug the dehumidifier into a properly Set the dehumidifier to the desired humidistat setting and turn
the brass outlet fitting on the rear of the dehumidifier. Fasten the hose securely grounded, GFI receptacle dehumidifier to the on position. Install the grill cover and secure
to the wall with a continuous downward slope to the drain (with no bellies or kinks with the enclosed tamper proof screws. Be careful not to over-
in the hose) so that it cannot be removed from the drain accidentally. tighten the screws.
*Install Notes: 1) Make sure drain hose is secured, not crimped (inside and outside of unit) and has continuous slope down and stays below the brass hose fitting outside of
the unit, 2) Make sure bottom of dehumidifier is supported in wall via sheetrock or framing, 3) After install each unit should be tested by slowly pouring water into drain pan
to ensure proper drainage, & 4)Remember there are no parts inside the dehumidifier that should be removed prior to installation including the Styrofoam noise insulation
shroud.

Summary of content (1 pages)