Promi-MSP™ Quick Installation Guide Version 2.0 For Wireless Multi-Serial Communications, based on Bluetooth Technology by Bluetooth Enabling Wireless Serial Communications Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
Contents 1. About Promi-MSP™ ............................................3 1.1 External View .................................................................................................................. 6 1.2 LED indicators................................................................................................................ 8 2. Installation ...........................................................9 2.1 Network Settings.......................................................................
Revision History: User Manual of Promi-MSP™ Version Changed Contents Date 1.0 Draft version 01/02/2003 1.1 Added user guide for Promi-MSP software 07/14/2003 1.2 Promi-MSP software upgrade and New commands added 08/11/2003 2.0 New functions of Promi-MSP102 series added 09/10/2004 1. About Promi-MSP™ Promi-MSP™ is a Bluetooth-wireless multiple serial communications port for minimum 7 to maximum 14 devices; an option to conventional multi-serial ports.
With Promi-SD™ installed at RS-232 interfaced terminals, Promi-MSP™ affords dependable convenience for a variety of serial communications environments. Refer to the figure 1.1. below: Promi-MSP™ is a wireless multi-serial Bluetooth technology-based server. Bluetooth SIG qualified protocol stack assures standardized, secure and scaleable serial communications. Promi-MSP™ identification of data, per each additional unique Bluetooth SPP enabled device address, prevents data jam. Bluetooth’s 2.
Promi-MSP 102(b) LAN 10/100 x2, - VirtualCOM and Serial/IP (Part no. : MSP00-10202) Inclusive Hub function. Ethernet/RS232C com. supported Supported Networks Built-in Bluetooth HTTP / FTP / Telnet / IP- 1 USB A-type port sharing(NAT) / DHCP /PPP for USB exention dongle server (Max. 14 Bluetooth links) * Promi-MSP101 was phased out as of August, 2004.
1.1 External View Promi-MSP 102(a)/(b) external view ① DIP Switch Users may select the way of data communication with Host. Default setting is TCP/IP communication using no. ④ RJ45 marked EXT, but if users need, data communication by no. ③ RS232 Interface marked “IOIOI” is also possible. If DIP switch is on the side of drawing , Promi-MSP communicates with Host via Ethernet line (TCP/IP). If users want to use RS232 com. please change the direction of switch to the other way.
This port can be used for both Configuration of Promi-MSP and Data communication with Host. ④ RJ45 marked EXT.: For connection to Host or HUB devices. For connection to PC, use a Crossed cable; for connection to HUB, use Straight Ethernet cable. ⑤ RJ45 marked INT.: For HUB port connection to another Promi-MSP™. This is for expansion of connections more than 14. ⑥ USB Extension Port: For expanding multi-connection beyond 7 devices.
1.
2. Installation Promi-MSP Installation Configuration via serial cable RS232 Mode TCP/IP mode Network Configuration Serial Port Configuration Mode configuration Change of DIP switch Connection from Bluetotoh Terminal device (Promi-SD) TIP If you are going to use Promi-MSP as RS232 mode – RS232 communication with Host, you don’t need to configure Networking settings. Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
2.
3. PPPoE: For assigning Promi-MSP™ a PPPoE IP (9) If No. 1, Static IP, is selected, the following is displayed on screen: (10) Enter user Static IP address. In the example below,192.168.0.3 is entered for the Promi-MSP™ IP address. Enter the user network appropriate IP address. (11) Please enter your Netmask/Gateway/DNS information, as in below for example: (12) Press Enter; Promi-MSP™ will prompt reboot request. Enter ‘Y’ [Yes]; press Enter to reboot Promi-MSP™ to apply the revised Network Settings.
(14) Revised Network settings are displayed (15) Networking configuration is complete. The preceding example shows static IP assignment to Promi-MSP™. User selects static, DHCP or PPPoE IP as needed. Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
2.2 LAN Access Profile Promi-MSP™ supports LAN Access Profile for Bluetooth networking Access Point. By direct connection of Promi-MSP™ to ADSL, the internet is accessible via Bluetooth. Select menu 2. LAP by entering ‘2’; Promi-MSP™ prompts for LAP profile enable/disable. Select ‘Y’ [Yes] to enable or ‘N’ [No] to disable LAP profile. TIP: For Internet connection, both LAP and PAN may be used. For more information, please refer to Appendix 5.4 Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
2.3 Firmware Download Promi-MSP enables user firmware upgrade. The INITIUM customer support team offers available firmware upgrades via Xmodem or TFTP user download; menu no. 3. Firmware Download. During Firmware download, STATUS and ERROR LEDs flash. DO NOT TURN OFF Promi-MSP™ during firmware download. Turning off Promi-MSP™ during firmware download may result in operation malfunction. There are two methods of firmware upgrade: 1. Xmodem 2. TFTP. 2.3.
2.3.2 Firmware Upgrade via TFTP: Users may upgrade the firmware using TFTP via Crossed cable. 3. Firmware Download → 2.TFTP Then you will get following screen: TFTPd ready. Send firmware using TFTP. Windows 2000/XP: tftp –i 192.168.1.10 put Please keep this serial console connected. For firmware upgrade via TFTP, network configuration of your PC which is connected to Promi-MSP should be changed.
Below window is showing the procedure of sending ROM file “msp2_040906.rom” to the connected Promi-MSP via TFTP. Users will be able to check the status of firmware upgrade in Serial console. Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
During upgrade, LEDs will flashing and users should NOT turn off Promi-MSP this time. If user cannot send the ROM file, please check the network connection status. Once ROM file is delivered to the connected Promi-MSP, the upgrade firmware will be recorded to momory. During this time both STATUS LED and ERROR LED will flashing speedly. NEVER turn off Promi-MSP during this firmware recording. Once finished, please resupply power to Promi-MSP for applying.
Chonfigurable ranges: Baudrate 1200 ~ 115200 bps Character size 8, 7, 6, 5 bits Parity Check None / Even / Odd Stop Bit 1 bit or 2 bits Hardware (RTS/CTS), Flow Control Software (XOn/Off), None For applying changed configuration, please RESUPPLY the power, then Promi-MSP will start to operate as RS232 mode. TIP: If you need to do data communication via RS232 port, you do not need to configure Network settings. Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
2.4 Reset/Reboot/Quit Entering no. 4, Promi-MSP™ RESET, in the main menu, restores all factory Default value settings. REBOOT restarts Promi-MSP™ for new configuration application. QUIT instantly aborts current processing. Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
3. Configuration If users finished configuring network settngs using serial console, now users need to select the operation mode of Promi-MSP. Following three (3) ways can be used for selection of operation mode: 1. Via Promi-MSP configuration software 2. Via Telnet (Control port) 3. Via Web brouser (Internet Explorer, etc.) In this chapter, guide to use Promi-MSP configuration software will be introduced. How to configure via Telnet or Web brouser will be introduced in Appendix. 3.
3.1.2 Log in Promi-MSP software For easier configuration and monitoring on a specific Promi-MSP, which has been installed locally or remotely, users may use Promi-MSP software. Start Promi-MSP software, and press “Search MSP device” button on the left side. Please select one Promi-MSP you would like to access and press “Connect” button.” Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
You will need to enter UserID/Password: admin/11111 3.1.2 Operation Mode Promi-MSP may be set to different type of Mode, so users may select one for its own implementation. There are 6 types of Mode: Server, Client, Vertex, Repeater, Serial Hub, and RS232. (RS232 Mode will be provided to Promi-MSP102 only) MSP Operation Mode This shows current type of Mode. Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
Mode Change Users may change and select the type of Operation mode. Search Promi-MSP Users may search Promi-MSP on the network. *Note: While Bluetooth devices are connected to Promi-MSP, mode change is not possible. a) Server Mode In Sever Mode, Promi-MSP will operate as a Server on the network. Host PC will connect to Promi-MSP via TCP/IP Ethernet, and Promi-MSP get the connection. After connection, full duplexing is possible.
If unregistered device tries to connect to Promi-MSP, Promi-MSP will assign the port number consecutively from Defalt Data port. KeepAlive Timeout When TCP connection is stopped unexpectedly (Ex. Power off of Host PC), Promi-MSP will request NULL during KeepAlive Timeout (second). If there is no response during this Timeout, TCP connection will be finished. Do not disconnect TCP socket In Server Mode, each TCP connection and Bluetooth connection will be matched as point-to-point.
Select “Advanced Configuration” button. Here, users may configure which Bluetooth device will connect to which Host as they need. Bluetooth device “00:0B:53:20:00:7E” will connect to Host “192.168.1.118”, port no. 5002. Bluetooth device “00:0B:53:20:00:74” will connect to Host “192.168.1.200”, port no. 5004. Bluetooth devices, which are not configured to connect to a specific Host, will connect to Default Host in Host information.
Try to Connect to Server every [ ] ms When Promi-MSP™ fails to open a data channel connecting to Host, enter the connection retry frequency. Entering 0 [zero] obtains retry abort. c) Vertex Mode Promi-MSP™ Vertex Mode avails Wireless RS485 multidrop service when assigned at this site. <그림 0-2> Vertex 모드 설정 Vertex Port For Promi-MSP™ Vertex port no. entry. Max Number of Connections For entering the number of Hosts connectable to Promi-MSP™.
Users may transmit/receive data via Promi-MSP in Serial Hub mode (Serial Hub). Serial Hub will deliver the data from a Bluetooth device to the other connected Bluetooth device. Users may configure the Bluetooth devices to use the Serial Hub in Advanced Configuration of Promi-MSP software. Point-to-Point - Press Start Button. - Then make connectrion from each Promi-SD to this Promi-MSP. You will have two Pormi-SDs, and this Promi-MSP will act as a Serial Hub to expand the range.
f) RS232 Mode Available only with Promi-MSP102. In RS232 Mode, Promi-MSP may communicate with other Bluetooth device via RS232 serial cable. As RS232 port has been configured to be used as Configuration as factory setting, users need to change the Switch on the left side of Promi-MSP to Data communication. Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
3.1.3 Bluetooth In this page, users can find current status of Promi-MSP. You can see the process of command at the bottom of each page as in Red circle above. TIP: For 14 connections in Promi-MSP102(b), please change the MaxDT to 14 above, after intalling USB extension dongle provided. Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
3.1.4 Connections In this page, users may MONITOR the connection status of devices to Promi-MSP. Now, a Bluetooth device named PSDv2h-0004E1 has been connected for Wireless serial communications as in below. If you want to Disconnect a Bluetooth terminal, you can do the job using DICONNECT button on the left. Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
3.1.5 Neighborhoods This page is to search nearby Bluetooth devices, every Interval, during the Length. < Neighborhoods> Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
Bluetooth Friendly Name of only ever-connceted devices will be appeared. 3.1.6 Repeater This page shows tree-structure how Repeater MSP and terminal devices are connected to the Station MSP. If user’s MSP is in Repeater Mode, nothing will be showed. In the captured window below, 2EA of Repeater MSPs are connected to a Station MSP and a Promi-SD is connected to 2nd Repeater(00:0B:53:20:00:3F). Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
3.1.7 MSP information Users may see Promi-MSP information currently accessing. LIST command in bottom box. NOTE: To find out more information on MODE of Promi-MSP, please refer to the Appendix 5.1 Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
4. COM port Redirector 4.1 COM port redirecotr NOTE: INITIUM provides VirtualCOM™ cost-free bundled with Promi-MSP™. Serial/IP™ requires additional cost. 4.1.1 Virtual COM Serial applications, communicating with devices directly through serial lines, need to communicate with serial Servers through networks. The HelloDevice VirtualCOM program enables this necessity.
If system the fails to run HelloDevice VirtualCOM at start-up or if the HelloDevice VirtualCOM is closed by selecting [Exit] menu at the tray, run the HelloDevice VirtualCOM manually by clicking short-cut [HelloDevice VirtualCOM / Run HelloDevice VirtualCOM]. [ Short-cut ] Run the HelloDevice VirtualCOM program so the serial application opens the virtual COM port and communicates with the serial server.
If the HelloDevice VirtualCOM is closed, activate it. [ HelloDevice VirtualCOM Tray Icon Menu ] Select [Configure] from the tray icon menu or double click the tray icon to open the [HelloDevice VirtualCOM] window. [ HelloDevice VirtualCOM window ] Selecting / Deselecting Virtual COM Port Open the [Create/Delete Port Dialog] dialog box by clicking [Port Select] button on the [HelloDevice VirtualCOM] window. [ Create / Delete Port Dialog ] Check the COM port for selection.
Uncheck the COM port to delete. • COM port, displaying [Not Connected serial App.] in the [remark] column, can be deleted. • COM port, displaying [Connected serial App.] at [remark] column, cannot be deleted; it is already connected to a serial application. Click [OK] button. Accordingly, COM ports are selected or deleted. [ HelloDevice VirtualCOM window after selecting / deleting COM port ] Setting the Properties of Virtual COM Port Check the COM port to set properties.
the last virtual COM port to create. This helps avoid rebooting when the virtual COM port is set. • Window NT series: By clicking [Set] button, the virtual COM port is created. • To change properties of the virtual COM port, set properties and click the [Set] button. Properties are set without rebooting Windows 9X or Windows NT series. Monitoring Virtual COM Port [TD] indicates that the serial application is sending data to the serial server.
5.1.2 Serial/IP Serial/IP is a serial port emulator enabling unmodified user TCP/IP socket communications Host Serial application program use. Users may download a 30day-trial version from http://www.tacticalsoftware.com after filling out simple forms for testing. INITIUM provides licensed Serial/IP programs to customers purchasing Promi-MSP™. The trial version Serial/IP does not require Serial Number for installation. Promi-MSP™ Fig. 4.1. Relationship between Serial/IP and Promi-MSP™ Fig. 4.2.
Fig. 4.3. Windows Tray after installation of Serial/IP (2) Click “Configure…” menu, and select the Virtual COM port to redirect to Serial/IP as in the left picture in Fig. 4.4 below. Enter IP address and Port number as in the right picture in Fig. 4.4 below. (3) Click “Configuration Wizard” button to connect to Promi-MSP™. (4) Promi-MSP™ is ready for use without revising Serial Port Applications. Fig. 4.5. Connection Configuration Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
4.2 Discovery Protocol UDP Broadcast on 9097 port Magic Number (4 bytes) Searching FA 05 21 EA 05 21 EF Response FA Format Magic Number (4bytes) Item # Item1 len Item2 … Item8 parameter Item list Item # length Parameter Example 0x01 Var. Product Name PROMI-MSP 0x02 Var. Model Code 101 0x03 Var. Product Serial Number MSP030403287 0x04 4 IP Address C0 A8 01 0A 0x05 2 Control port (big endian) 09 DD 0x06 6 MAC address 00 0B 52 10 00 36 0x07 Var.
0 8 16 24 32 Magic1 (=FAh) Magic2 (=05h) Magic3 (=21h) Magic4 (=EFh) Item1(=01h) Len1(=09h) P R O M I - M S P Item2(=02h) Len2(=03h) 1 0 1 Item3(=03h) Len3(=0Ch) M S P 0 3 0 4 0 3 2 8 7 Item4(=04h) Len4(=04h) C0h A8h 01h 0Ah … Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.
Promi-MSP™ Installation Guide ver. 2.0 www.initium.co.