User's Manual

INID XS readers Installation Manual
Models
number name interfaces
article
number
5040C INID SmartReader XS PIN WG/C&D/TTL + RS485 500-5040C
5000C INID SmartReader XS WG/C&D/TTL + RS485 500-5000C
5045C INID MultiSmart XS PIN WG/C&D/TTL + RS485 500-5045C
5005C INID MultiSmart XS WG/C&D/TTL + RS485 500-5005C
5240C INID SmartProx XS PIN WG/C&D/TTL + RS485 500-5240C
5200C INID SmartProx XS WG/C&D/TTL + RS485 500-5200C
Classifications
UL 294: destructive attack level IV, line security level I,
endurance level IV, standby power level I
ULC S319: class III
Specifications
Dimensions
143 x 50 x 25 mm / 5⅝ x 2 x 1 inch
Operating temperature
-25° to 65° C / -15° to 150° F
Protection class
IP54 Complete protection against contact, protection
against dust deposit.
Protection from splashed water.
Power Supply
All models 7.0 - 24 Volt DC
models
Watts
mA
at V
min
at 12 V
DC
at V
max
avg peak avg peak avg peak avg peak
5000C INID SmartReader XS 1,50 2,35 215 340 125 200 65 100
5040C INID SmartReader XS PIN 1,50 2,55 215 365 125 215 65 110
5005C INID MultiSmart XS 1,50 2,35 215 340 125 200 65 100
5045C INID MultiSmart XS PIN 1,50 2,55 215 365 125 215 65 110
5200C INID SmartProx XS 0,85 2,00 125 290 75 170 40 85
5240C INID SmartProx XS PIN 0,85 2,00 125 290 75 170 40 85
Note: Ohms’ Law may be used to estimate current at other voltages.
Parts included (1 each)
Reader front
Mounting backplate
Enclosure screw (Torx #8)
Installation manual
Certifications
CE, FCC, IC, UL, ULC
FCC ID: YAB-MSXSRDR (MultiSmart XS readers)
YAB-SPXSRDR (SmartProx XS readers)
YAB-SRXSRDR (SmartReader XS readers)
IC: 8908A-MSXSRDR (MultiSmart XS readers)
8908A-SPXSRDR (SmartProx XS readers)
8908A-SRXSRDR (SmartReader XS readers)
Consult your National Authority if any authorization is needed for
these products.
Warning (part 15.21)
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate
the equipment.
Compliance statement
This device complies with part 15 of the FCC Rules and with the
Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Information to the User (Part 15.105 (b))
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Complies with: CAN ICES-3 (B)/NMB-3(B)
Operation
When a credential is read successfully, the LED bar lights briefly, the
sounder sounds a short tone and the credential associated code is sent
to the Host system.
The LED bar and sounder are also controllable by the Host system.
When a PIN is entered the data is sent to the Host system; at each key
press a click sound is produced and the LED bar lights briefly. The
backlight of the PIN code lights up after a successful credential read, or
at the first key press.
Reader output formats are determined by the personalization of the
credential and/or configuration of the reader; on SmartReader and
MultiSmart readers the behaviour of the LED bar and sounder can be
modified through configuration.
When the reader detects a tamper status, the LED bar flashes red and
the tamper output is activated; on SmartReader and MultiSmart
readers this behaviour can be modified through configuration.
Document 100.14.IS.01 v1.30, effective from SN1632-0001 page 1 of 2 printed on Aug 8, 2016
INID BV
Overweg 5
1713 HX Obdam
The Netherlands
Phone: +31 (0)226 450 009
Web: www.inid-readers.com

Summary of content (2 pages)