InHand ER805-NRQ3 User Manual InHand ER805-NRQ3 5G Edge Router User Manual V1.0—2021.09 www.inhand.com.cn Beijing InHand Networks Technology Co., Ltd.
InHand ER805-NRQ3 User Manual Declaration Thank you for choosing our product. Before using this product, please read this manual carefully. The contents of this manual cannot be copied or reproduced in any form without the written permission of InHand. Due to continuous updating, InHand cannot promise that the contents are consistent with the actual product information, and does not assume any disputes caused by inconsistency of technical parameters.
InHand ER805-NRQ3 User Manual CONTENTS 1 Overview ............................................................................................................. 1 2 Hardware ............................................................................................................ 2 2.1 Indicator Description ...............................................................................................2 2.2 Restoring to Default Settings via the Reset Button ......................................3 2.
InHand ER805-NRQ3 User Manual 11 Security ...........................................................................................................27 11.1 Inbound/Outbound Rules ................................................................................ 27 11.2 Port Forwarding ................................................................................................... 28 12 Services ...........................................................................................................
InHand ER805-NRQ3 User Manual 1 Overview InHand ER805-NRQ3 5G Edge Router is a new generation 5G edge router launched by InHand Networks. With 4G / 5G wireless network and a variety of broadband services, this product can provide Internet access for all industries of IoT. The product adopts SD-WAN technology to provide uninterrupted data communication link experience for industry applications.
InHand ER805-NRQ3 User Manual 2 Hardware 2.1 Indicator Description ER805-NRQ3 Indicator System LED Status and Definition Steady off --- Power off. Blinking in blue --- System starting. Steady in blue --- System operates properly. Blinking in red --- System faults. Blinking in green --- System upgrading. Network Status Blinking in red --- Network connection lost. Blinking in green --- Cellular network connecting. Steady in green --- Cellular network connected.
InHand ER805-NRQ3 User Manual 2.2 Restoring to Default Settings via the Reset Button To restore to default settings via the reset button, please perform the following steps: 1. Press the RESET button immediately after power on the device. 2. System indicator will blink after a few seconds, and after blinking for about half a minute, it will be steady on. 3. Release RESET button, System indicator will blink, and press the RESET button again. 4. When System indicator blinks slowly, release the RESET button.
InHand ER805-NRQ3 User Manual 2.3 Antenna: List of antenna: Type of Antenna Model Number Manufacturer Max Gain 5G Sucker antenna GY-XDK-OCL2-B2JG24.1 ShenZhen GuYou Technology Co., Ltd. 5dBi WiFi Sucker antenna GY-XPF-BCL2.5-GJG22 ShenZhen GuYou Technology Co., Ltd. 3dBi Note: 1. Cellular1 is the main antenna of the 3/4G, Cellular2 is the AUX antenna of the 3/4G. 2.
InHand ER805-NRQ3 User Manual 3 Default Settings No. Function 1 Cellular Default Settings − Dual SIM card enabled, use SIM1 by default. − Wi-Fi 2.4G AP mode enabled, SSID: ER805-NRQ3followed with the last 6 letters of the AP MAC. − 2 Wi-Fi Wi-Fi 5G AP mode enabled, SSID: ER805-NRQ3-5Gfollowed the last 6 letters of the AP MAC. − Auth Method is WPA2-PSK. − Both WPA/WPA2 PSK keys in two mode are the last 8 letters in serial number. 3 Ethernet − 4 LAN are enabled. − IP Address: 192.168.2.
InHand ER805-NRQ3 User Manual 4 Login and Network Access 4.1 Network Access via Ethernet Step 1: Connect power and Ethernet cable to ER805-NRQ3, connect WAN port to public network, and one of LAN to PC. Step 2: Configure PC to be in the same network segment as the IP address of the router. (1) Enable PC to obtain an IP address from DHCP automatically (recommended). (2) Configure a fixed IP address in the same network segment as the router for PC.
InHand ER805-NRQ3 User Manual Obtain an IP address automatically/manually Step 3: Access to the default IP address 192.168.2.1 in a browser, enter username and password(adm/123456 by default) then access to router’s WEB management page. If the browser alarms the connection is not private, show advanced, and proceed to access to the address.
InHand ER805-NRQ3 User Manual Step 4: Create a WAN port in “Internet” in the left menu. ER805-NRQ3 wiill enable WAN1 as DHCP mode by default. It will connect to Internet is the upstream device also works in DHCP mode. There are two methods to obtain IP address: Dynamic DHCP (recommend) and Static IP (save after configure manually).
InHand ER805-NRQ3 User Manual Obtain IP address by Static IP Step 5: Check the connectivity in “System >> Tools >> Ping”.
InHand ER805-NRQ3 User Manual 4.2 Network Access via SIM card Step 1: Insert the SIM card when device is power off. Connect 4 4G/5G antennas to the router, and connect PC to router. Then power on. Note: When insert or plug out SIM card, please unplug the power cable to prevent data loss or damage the router. ER805-NRQ3 supports 4 antennas, please connect all antennas to obtain high communication quality. Step 2: Open a browser and access to router’s WEB management page. (refer to 4.
InHand ER805-NRQ3 User Manual within a few minntes. If the device cannot connect to Internet, please disable and restart dialup. (If you use a private network SIM card, you also need to configure APN parameter) Step 4: Check the dialup status in “Dashboard >> Interface Status”, if it shows green in Cellular icon, the router has connected to Internet by SIM card. Click Cellular icon to get check more dialup information like signal strength, IP address or DNS.
InHand ER805-NRQ3 User Manual 4.3 Network Access via Wi-Fi Step 1: Connect Wi-Fi antenna, and connect PC to the device. Access to router’s WEB management page. (refer to 4.1) Step 2: Choose the frequent band of Wi-Fi. ER805-NRQ3 supports 2.4G and 5G Wi-Fi. These two Wi-Fi can work independently at the same time. 2.4G Wi-Fi has higher penetration while 5G Wi-Fi has higher transmission speed. You can check Wi-Fi status in “Wi-Fi” of the left menu. Step 3: Set Station Role in “Wi-Fi 2.
InHand ER805-NRQ3 User Manual Client mode: ER805-NRQ3 connects to other AP Wi-Fi device to access the Internet. Click Add button in “Internet” page, select “Wi-Fi(STA)” and then configure other parameters.
InHand ER805-NRQ3 User Manual 14
InHand ER805-NRQ3 User Manual 5 Dashboard Click “Dashboard” in the left menu to access to Dashboard, and check Device Information, Interface Status, Traffic Statistics and other information of the device. Click interface icon in Interface Status, and check detailed information of the interface in the right menu.
InHand ER805-NRQ3 User Manual 6 Status Click “Status” in the left menu to access to status page, check events and clients connected to this device and VPN status in this device. 6.1 Events Router will record event log like user login, configuration changed, link changed, reboot and other events in Events page, By selecting start data, end date and event type, narrow the scope of retrieval and view a certain type of event. 6.
InHand ER805-NRQ3 User Manual 17
InHand ER805-NRQ3 User Manual 7 Internet Click “Internet” in the left menu to check and configure the upstream interface of the ER805-NRQ3, and the elementary options for SDWAN. 7.1 Internet List User can check the status of the upstream link interface, add or delete WAN2 or Wi-Fi (STA) interface and edit or set policy for these interface. ER805-NRQ3 support up to two WAN interface, LAN1 will change to WAN interface if open WAN2.
InHand ER805-NRQ3 User Manual 7.2.1 Optimal Forwarding & Load Balancing ER805-NRQ3 supports working at optimal forwarding mode or load balancing mode, and use optimal forwarding by default. Optimal Forwarding: ER805-NRQ3 will choose the best available link to forward data traffic in this mode. Load Balanciing: ER805-NRQ3 will distribute data traffic to all available links by hash algorithm.
InHand ER805-NRQ3 User Manual 8 Local Network User can check and configure LAN of the device is Local Network page. Edit network: Click the Edit button in the right to edit current LAN, allow user to change the range of IP address and DHCP server. Add network: Add a new LAN by clicking the Add button in the left, set the Name, VLAN, DHCP server and other parameters of this new network.
InHand ER805-NRQ3 User Manual 21
InHand ER805-NRQ3 User Manual 9 Wi-Fi Client devices can use Wi-Fi to connect to ER805-NRQ3 to access to Internet, or ER805-NRQ3 can use Wi-Fi to connect to other AP. User can check, add or configure Wi-Fi network in Wi-Fi page. Edit Wi-Fi: Click Edit button in the right, configure SSID, password or other parameters of this Wi-Fi.
InHand ER805-NRQ3 User Manual Add Wi-Fi: Add a new Wi-Fi by clicking Add button in the left. If there is a Wi-Fi (STA) interface use the same frequency with the new Wi-Fi, the Status of the new Wi-Fi will be disable and not able to change.
InHand ER805-NRQ3 User Manual 24
InHand ER805-NRQ3 User Manual 10 VPN VPN is intended to establish a private network on the public network for encrypted communication. A VPN router enables remote access by encrypting data packets and converting the destination address of data packets. VPN can be realized by a server, hardware, or software. Compared with the traditional DDN private line or frame relay, VPN provides a more secure and convenient remote access solution. Click “VPN” in the left menu to access to VPN configure page. 10.
InHand ER805-NRQ3 User Manual 26
InHand ER805-NRQ3 User Manual 11 Security Click “Security” in the left menu to enter Security page, and configure Inbound/Outbound rules and port forwarding. 11.1 Inbound/Outbound Rules User can set rules to control data traffic based on interface. For example: User can use inbound rules to forbid some of IP addresses to access to router when under attack from such IP. User can use outbound rules to forbid some client devices to access to public network.
InHand ER805-NRQ3 User Manual 11.2 Port Forwarding When outside network accesses to some of ports of the router, ER805-NRQ3 will transfer this data to corresponding ports of inside device according to port forwarding rules. So that the service deployed in LAN can be available for public network, and one public IP can access to plenty of services by using multiple port forwarding rules. For example, when public network access to ER805-NRQ3’s port 2000, router will transfer this data to 192.168.2.
InHand ER805-NRQ3 User Manual 29
InHand ER805-NRQ3 User Manual 12 Services 12.1 Interface Management Configure enable/disable and the speed of each LAN interface. 12.2 DHCP server DHCP uses client/server communication mode. The client submits a configuration application to the server, and the server returns the IP address assigned to the client, in this way, DHCP realizes the dynamic configuration of the IP address. ER805-NRQ3 builds DHCP service based on internet list. DHCP server will be deleted if corresponding LAN is deleted.
InHand ER805-NRQ3 User Manual ER805-NRQ3 will distribute IP address based on MAC address by using fixed address list. Distributed IP address should in the range of IP address of the local network. 12.4 Static Routes ER805-NRQ3 will forward data by specific route or interface after configure static routes in this page. This list will only display the rules created by user, and will not show the routes created automatically after modifying WAN or LAN interface.
InHand ER805-NRQ3 User Manual 13 System 13.1 Cloud Management User can select which InHand platform to connect to in this page, and also disable InStarCloud service this page. 13.2 Change the Password The default username and password of ER805-NRQ3 is adm/123456. Please change the password for securiry. Click “adm” on the top right of the page, click Modify Password in the menu to change the password.
InHand ER805-NRQ3 User Manual 13.3 Remote Access Control User can allow or forbid public network to access to ER805-NRQ3 and which port for public network to access to ER805-NRQ3 in this page. This rule will not influence LAN device to access to ER805-NRQ3. ER805-NRQ3 supports HTTP and HTTPS when access to its web configuration page. 13.4 System Clock Router should have accurate system time to ensure client devices work without mistake.
InHand ER805-NRQ3 User Manual NTP server: Configure domain name and port of the NTP server, ER805-NRQ3 will connect to this server to get correct time. 13.5 Device Options Reboot, upgrade firmware or reset to default factory settings in this page. 13.6 Configuration Management User can export system configuration to local PC, and import the configuration when device gets error.
InHand ER805-NRQ3 User Manual 13.7 Device Alarms When user needs to pay attention to some of events going to happen in the device, user can select corresponding alarm events and set an email address to receive alarm email. ER805-NRQ3 will still record alarm events in “Status >> Events” even user does not select alarm events in this page. ER805-NRQ3 supports to record and alarm these events at present.
InHand ER805-NRQ3 User Manual 13.8 Tools 13.8.1 Ping Use ICMP protocol to check the connectivity to other IP address or domain name. Enter IP address or domain name in “Target”, and click “Start” to start ping. 13.8.
InHand ER805-NRQ3 User Manual Enter target IP address or domain name, select interface, and click “Start”. ER805-NRQ3 will trace link situation from itself to the target. 13.8.3 Capture User can use this feature to catch the data forwarding through one of the interfaces. User can choose to view the result in below chart or export the capture file to local PC by selecting Output option. 13.8.
InHand ER805-NRQ3 User Manual FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device , pursuant to part 15 of the FCC Rules.
InHand ER805-NRQ3 User Manual IC STATEMENT This device complies with Industry Canada license-exempt RSS standard(s): Operation is subject to the following Two conditions: (1) this device may not cause interference, and Frequency band 5150-5250 MHz restricted for indoor use only. (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.