TianXuan M Series Handheld Thermal Camera User Manual ©IRay Technology Co.,Ltd. 2020 Reserve all the right. All in this manual including texts, pictures, diagrams and other contents belong to IRay Technology Co.,Ltd (Hereinafter referred to as “Our company” or “IRay Photoelectric”). Without the written permission, no one shall copy, photocopy, translate or disseminate all or part of this manual.
TianXuan M Series Handheld Thermal Camera User Manual Table of Contents 1. Notices to the User ................................................................................... 1 1.1 Calibration........................................................................................... 1 1.2 Accuracy ............................................................................................. 1 1.3 Manual Update .................................................................................... 1 1.
TianXuan M Series Handheld Thermal Camera User Manual 4.8.1 Image Mode Introduction ........................................................... 8 4.8.2 Setting Steps ............................................................................... 9 4.9 Non-uniformity Correction ................................................................. 9 4.9.1 Non-uniformity Correction Introduction .................................... 9 4.9.2 Non-uniformity Correction Operations ......................................
TianXuan M Series Handheld Thermal Camera User Manual 1. Notices to the User 1.1 Calibration We recommend that you conduct calibration once a year. 1.2 Accuracy For very accurate results, we recommend that you wait 5 minutes after you have started the camera before measuring a temperature. 1.3 Manual Update The user manual will be updated from time to time. Please contact our company to get the latest version. 1.
TianXuan M Series Handheld Thermal Camera User Manual 4.Image Capturing Click the trigger button to capture the image, and record the video by long pressing the trigger button. 5. Analysis by PC Software Run the client after downloading the software to PC, and then use a USB cable or SD card to import data for further analysis. Note: Please import the files of the same name with suffixes of jpg and irg together with the data. The file with the suffix irg contains data related to temperature.
TianXuan M Series Handheld Thermal Camera User Manual 2. Digital camera 3. Laser pointer 4. Photo trigger 3.2 Buttons(View from the rear) 7 1 5 2 6 4 3 Figure3.2 Introduction to Buttons Components 1.Display screen 2.Gallery button Press to open the gallery. Long press to perform image uniformity correction. 3.Navigation button Make selections for the menu, settings, gallery by clicking up/down/left/right. 4. Power/Laser button Long press to turn on/off.
TianXuan M Series Handheld Thermal Camera User Manual 7.Microphone It’s used to record voice notes after shooting. 3.3 Connector and Memory Card 1 2 Figure3.3 Illustration of Connector and Memory Card 1. USB Interface ⚫ Connect a USB cable with the power adapter for charging. ⚫ Connect a USB cable to a computer to charge or transfer data. 2. SD Card ⚫ Standard MicroSD card, standard 32GB,Max 32GB. ⚫ The SD card can be taken out and transfer data to PC or other devices with a card reader. 3.
TianXuan M Series Handheld Thermal Camera User Manual Interface Introduction 1. Main Menu: measurement parameters, measurement mode, image mode, color palettes and other settings can be set. 2. Sub Menu: specific options can be set, such as a specific color palette. 3. Temperature measurement spot: measurements of center spot, high/low temperature spot tracking, customize spot, customize line, customize area measurement are available. 4.
TianXuan M Series Handheld Thermal Camera User Manual Note:When the battery is not placed, the indicator of the charging base flashes; the indicator turns red when the battery is placed and charging; the indicator becomes green when the battery is fully charged. 4.2 Power On/Off 1. Press the power button continuously to start the device. 2. Press the power button about 3 seconds to turn it off. 4.3 Take Photos/Videos 1. In the observation interface, adjust the focus ring till the image is clear.
TianXuan M Series Handheld Thermal Camera User Manual 4.5 Measurement Mode In the observation interface, press OK shortly to enter the main menu, and select "Measurement Settings" with the navigation button. Press OK again to enter the secondary menu, select different measurement modes by shifting left or right on the navigation button, and press OK to save your option. In the observation interface, click anywhere on the screen to enter the main menu.
TianXuan M Series Handheld Thermal Camera User Manual ⚫ Ambient temperature: the reflection temperature of the object surface will affect the measurement result, especially when the object emissivity is low or the object temperature and the reflection temperature differ greatly, this effect will increase. So the result needs to be compensated to eliminate influences of the surface reflection temperature. However, it is usually difficult to determine the reflected temperature of an object.
TianXuan M Series Handheld Thermal Camera User Manual thermal camera to the object. If the preset registration parameters cannot meet the requirements, you can also manually perform fusion registration in the settings. 4.8.2 Setting Steps In the observation interface, press OK shortly to enter the main menu, and select "image mode" through the navigation button. Then press OK again to enter the secondary menu, there different image mode can be selected by shifting left or right on the navigation button.
TianXuan M Series Handheld Thermal Camera User Manual 1)In the observation interface, press OK shortly to enter the main menu, and select "Settings" to enter other settings. 2)In the observation interface, tap anywhere on the screen to enter the main menu, and tap "Settings" to enter other settings. 4.11.1 Date and Time 4.11.2 Languages ⚫ Simplified Chinese ⚫ English 4.11.
TianXuan M Series Handheld Thermal Camera User Manual ⚫ Temperature setting for low temperature alarm: click on the pop-up keyboard and set the alarm temperature. 4.11.6 Display Brightness ⚫ High brightness: click to set the screen brightness as high brightness. ⚫ Medium brightness: click to set the screen brightness as medium brightness. ⚫ Low brightness: click to set the screen brightness as low brightness. 4.11.7 Automatic Power-off ⚫ 5Min: click to set automatically shut down after 5 minutes.
TianXuan M Series Handheld Thermal Camera User Manual This function can be used to manually register infrared and visible images. First select coarse tuning and fine tuning, and then perform image registration by the touch screen or navigation keys. After finished, click OK or enter button to save the settings. ⚫ Picture-in-picture Adjustment This function can be used to adjust the position of the picture-in-picture.
TianXuan M Series Handheld Thermal Camera User Manual 2. Ideal working temperature is-10℃~50℃. 3. Do not touch the lens with your hands or other things. 4. Do not touch the device with wet hands. 5. Do not wipe and clean your device with diluent. 6. Please do not wrongly connect the attached cables to avoid damage to the device. 7. Please take care to avoid static electricity. 8. Please do not disassemble the device. If there is any problem, please contact our company for professional maintenance. 7.
FCC Warning § 15.19 Labeling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. § 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. § 15.