CU5300/5303W Control Unit Technical Description Document TDD V1.0.
DRAFT INDYME CONFIDENTIAL FOR INTERNAL USE ONLY
CONTENTS Glossary .................................................................................................................................. 5 Introduction ............................................................................................................................ 5 Port Overview ......................................................................................................................... 7 Functional Description .........................................................
Revision History Version # Date Author(s) Summary of Changes 1.0 12/22/2016 Mike Sheppard Initial draft. 1.0.
Approvers Name Project Role Approval Date Derek Morikawa Technical Sponsor GLOSSARY Abbreviation/Acronym Term Description CU5300 Control Unit Smart Control Appliance CU5303W Control Unit Smart Control Appliance for Walgreens INTRODUCTION The CU5300/5303W is the next generation control platform for the Smart Response System.
CU5303W Connect RS CRS (Walgreens) CU5300 Connect RT CRT CU5301 Connect RV CRV (Kohls)
PORT OVERVIEW The RECEIVER Port is used to connect the Control Unit to 303MHz CB451 Call Box Receivers ONLY. The RECEIVER Port provides +12VDC to support a maximum of (4) CB451 Receivers. CB451 Call Box Receivers are connected using an RJ45 modular plug and CAT-5 cable The A1 and A2 indicators are multi-color LEDs used to indicate the status of the two AUDIO Ports. Each LED will light up RED or GREEN to indicate the status of the corresponding Audio Port. Both LEDs are on during normal operations.
FUNCTIONAL DESCRIPTION 1. Overview The CU5300 is the latest hardware control unit developed by Indyme to be the central interface for the Global Solution Family (GSF) of Smart Sense Devices, legacy Call Boxes, and Shopper Help Buttons. The CU5300/5302W offers an easy to configure and install solution for rapid deployment of a completely integrated system offering. The CU5300 accepts triggers from GSF help buttons and Smart Sense devices over the network via CB451 or CB951 transceivers.
2. Capacity The CU5300/5303W • • • Supports a minimum of 4,000 wireless device capability (i.e., 0001 – 3999) Supports a minimum of 1,000 Ethernet inputs that are separated from the wireless addresses Supports a minimum of 60 minutes of audio storage 3. RF Output The CU5300/5303W • • • Frequency Range: 868.175 - 869.675 MHz and 918.1 – 923.0 MHz Modulation Type: 2-GMSK frequency hopping spread spectrum Antenna Type: Omni-Directional dipole, +2dBi maximum gain, RP-SMA connector 4.
• • • Direct Audio 2 has an Audio In, Audio Out, Busy In, and a PTT out (same as the Direct Audio 2 port on the CLX/CLT). Direct Audio 2 is a standard RJ45 with the same pinouts as current CU’s. This port is used with existing PT14 and PT14-1 units, and will be 100% reverse compatible. 7.
10. Scheduled Messaging (Promos) • • • By default, Interval promos are disabled. By Default, Day Time promos are disabled. By default, Time Of Day promos are disabled. 11. Email Output • • By default, definable email output addresses are limited to five (5). In future sw releases, a License key or other method of unlocking features will be required to enable additional functionality. 12.
15. SmartPortal Support • • The CU5300/5303W is fully supported by Smart Portal Smart Portal is capable of managing: • Software updates (Full Linux upgrade not available with CU Release 1.0)! • Configuration management • Data collection • Message management 16. Power • • The CU5300/5303W power supply: o Input voltage range 120/240 VAC 50-60 Hz, 0.4 Amps maximum o Ouput voltage +12 VDC at 1.25 Amps o Note that the adaptor has a maximum power of 100VA available.
20. FCC and IC Statements FCC statements: “This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.” “Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
peuvent être obtenues: http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct/index-fra.php” REFERENCES AND RELATED DOCUMENTS Title Link MPR http://sharepoint1/prodmgmt/MPRs/Forms/AllItems EFS http://sharepoint1/ProjectMgmt/Engineering%20Functional%20Specifications%20EF S/Forms/AllItems.