Washdown Rated Stainless Steel Pedestal and Wall Mounted Fan MODEL: ILG8WD24-2P ILG8WD24-1W ILG8WD30-2P ILG8WD30-1W Owner’s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS Important Instructions………………………………………. 3-4 Specifications……………………..………………………….. 4 Parts of the fan.............................................................. 5-6 Installing Instructions……………………….…………..… 7-9 Electrical Wiring ........……………………….………....… 10-12 Maintenance and Cleaning………………………………. 12 Troubleshooting…………………………………………….
IMPORTANT INSTRUCTIONS CAUTION: Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Do not use the fan if any part is damaged or missing. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
11. Make sure the fan is on a stable, flat surface while it is in operation. 12. Disconnect the fan when removing the guards for cleaning. WARNING: The fan must be grounded and installed in A GFCI Protected Branch Circuit. Improper connection may create the risk of electrocution. Use of such adapters is prohibited in Canada. WARNING: Do not depend on any switch as the sole means of disconnecting power when installing or servicing the fan. Failure to do so may result in fatal electrical shock.
PARTS OF THE FAN For the Washdown Rated Stainless Steel Pedestal Fan Model: ILG8WD24-2P & ILG8WD30-2P CONTAINS REF QTY DESCRIPTION PART NUMBER 1 1 Front Fan Guard SP-D242P-1 & SP-D302P-1 2 1 Blade SP-D242P-2 & SP-D302P-2 3 1 Rear Fan Guard SP-D242P-3 & SP-D302P-3 4 1 Motor Assembly SP-D242P-4 & SP-D302P-4 5 1 Upper Column SP-D242P-5 & SP-D302P-5 6 1 Lower Column SP-D242P-6 & SP-D302P-6 7 1 Base Assembly SP-D242P-7 & SP-D302P-7 5
For the Washdown Rated Stainless Steel Wall Mounted Fan Model: IILG8WD24-1W & ILG8WD30-1W CONTAINS REF QTY DESCRIPTION PART NUMBER 1 1 Front Fan Guard SP-D241W-1 & SP-D301W-1 2 1 Blade SP-D241W-2 & SP-D301W-2 3 1 Rear Fan Guard SP-D241W-3 & SP-D301W-3 4 1 Motor Assembly SP-D241W-4 & SP-D301W-4 5 1 Wall Mounting Bracket Assembly SP-D241W-5 & SP-D301W-5 6
INSTALLATION INSTRUCTION PRE-INSTALLATION: All necessary screws are installed in the associate part for ease of tracking for customer. Please use the following pictures as guide to locate installation parts. For the Washdown Rated Stainless Steel Pedestal Fan (Model: ILG8WD24-2P & ILG8WD30-2P) Base Assembly INSTRUCTIONS: 1. Loosen the screw from the base assembly, insert the lower column to the base assembly. Align the hole of the lower column and base assembly , then tighten it. 2.
4. Insert the blade into the motor shaft until it reaches a stopping point and the set screw is in line with the flat groove on the motor shaft. NOTE: Make sure the blade’s set screw is facing the motor. You may need to loosen the set screw at the rear of the blade to slide it onto the shaft. 5. Firmly tighten the blade’s set screw with the spanner (not supplied). CAUTION: Do not alter the angle of the blades. 6.
If mounting on a concrete wall, be sure to locate a structurally solid and secure location to hold the weight of the fan assembly and use suitable concrete anchors (not provided ) to mount the base to the wall. WALL MOUNT BRACKET/ MOTOR ASSEMBLY 1. Remove the 2 bolts, washers and nuts from the mounting bracket. 2. Align the holes on the mounting bracket with the holes in the motor flange on the motor assembly. 3. Insert the bolts and replace the washers and nuts removed in step 1. 4.
OPERA ELECTRICAL WIRING Your licensed electrician is responsible for providing all electrical components and making all necessary connections from the motor to the appropriate power source. All Washdown Rated Stainless Steel Fans come with a wiring schematic, usually printed on the nameplate of the motor. Fans must be wired exactly as shown. This is a dual voltage motor, take care to select the correct wiring configuration based on your voltage level.
Figure 2 Figure 3 11
Table 1 Plug and socket Wiring 115V, according to the user socket, you can choose 5-15P, 5-20P, 5-30P,5-50P. Wiring 230V, according to the user socket, you can choose 6-15P, 6-20P, 6-30P,-50P. MAINTENCE AND CLEANING WARNING: Parts replacement and troubleshooting to be performed only by qualified personnel. WARNING: Do not depend on any switch as the sole means of disconnecting power when installing or servicing the fan. Failure to do so may result in fatal electrical shock.
TROUBLE SHOOTING If your fan fails to operate, please follow these Instructions: 1. Make sure the fan is plugged in and the electrical outlet is working properly. 2. Check for any obstruction. If you find an obstruction, turn the fan “OFF”. Unplug the fan and carefully remove the obstruction. Plug the fan in and turn it on again and see if it resumes normal. NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR FAN, PLEASE DO NOT ATTEMP TO OPEN OR REPAIR THE FAN YOURSELF.
Warranty Information This product comes with a 1-YEAR LIMITED COMPONENT WARRANTY. If your unit does not appear to be working properly, please contact our service center by calling 1-800-317-1688. Prior to your call, we encourage you to visit our service related website www.ilivingusa.com for troubleshooting tips and service instructions if needed. Register your product at our website: Or visit iLivingUSA.com/register-product Feedback Love it? Help us make the product more for you.