Produkte Products Prüfbericht-Nr.: Test Report No.: 50261218 001 Auftrags-Nr.: Order No.: Kunden-Referenz-Nr.: Client Reference No.: N/A Auftragsdatum: 08. 07. 2019 Order date: Auftraggeber: Client: Shenzhen Mazepower Technology Ltd. Room 707, 7/F, Tower A, Da Tang Shi Dai Building, No.2203 Meilong Avenue, Long Hua District, ShenZhen, China Prüfgegenstand: Test item: USB C PD Wall Charger 168122578 Seite 1 von 59 Page 1 of 59 Bezeichnung / Typ-Nr.
www.tuv.com Page 2 of 59 Report No.: 50261218 001 TEST REPORT IEC 60950-1 Information technology equipment – Safety – Part 1: General requirements Report Number........................... : 50261218 001 Date of issue.............................. : See cover page Total number of pages................. See cover page Name of Testing Laboratory preparing the Report .................. : See cover page Applicant’s name ....................... : See cover page Address.................................
www.tuv.com Page 3 of 59 Report No.: 50261218 001 Test item description.................... : USB C PD Wall Charger Trade Mark .................................. : No trademark used on the product Manufacturer ............................... : Same as applicant. Model/Type reference ................... : MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Ratings........................................
www.tuv.com Page 4 of 59 Report No.: 50261218 001 List of Attachments (including a total number of pages in each attachment): - see cover page Summary of testing: Tests performed (name of test and test clause): Testing location: 1. Max. ambient temperature +25°C. See cover page 2. Following tests performed during evaluation Clause(s) Test(s) 1.6.2 1.7.11 2.1.1.1 2.1.1.5 2.1.1.7 2.2.2 2.2.3 2.4 2.5 2.9.2 2.10.2 2.10.3 & 2.10.4 4.2.4 4.2.6 4.2.7 4.3.6 4.5.2 4.5.5 5.1.6 5.2 5.
www.tuv.com Page 5 of 59 Report No.: 50261218 001 Copy of marking plate: Note: Since similar rating label used, only above model listed to represents all other models. TRF No.
www.tuv.com Page 6 of 59 Report No.: 50261218 001 Test item particulars......................................... : Equipment mobility.................................................: [] movable [] hand-held [] transportable [] stationary [] for building-in [x] direct plug-in Connection to the mains........................................
www.tuv.com Page 7 of 59 Report No.: 50261218 001 Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided ....................................................
www.tuv.com Page 8 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 1 GENERAL P 1.5 Components P 1.5.1 General P Comply with IEC 60950-1 or relevant component standard (see appended tables 1.5.1) P 1.5.2 Evaluation and testing of components Components which are certified to IEC and/or national standards are used correctly within their ratings. Components not covered by IEC standards are tested under the conditions present in the equipment.
www.tuv.com Page 9 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark 1.5.9.4 Bridging of basic insulation by a VDR 1.5.9.5 Bridging of supplementary, double or reinforced insulation by a VDR 1.6 Power interface 1.6.1 AC power distribution systems TN power system P 1.6.2 Input current Highest load according to 1.2.2.1 for this equipment is the operation with the maximum specified by the manual instruction. (see appended table 1.6.2) P 1.6.
www.tuv.com Page 10 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 1.7.2.1 General P 1.7.2.2 Disconnect devices Mains plug serves as disconnect device. P 1.7.2.3 Overcurrent protective device Not such equipment. N/A 1.7.2.4 IT power distribution systems 1.7.2.5 Operator access with a tool No operator accessible area that needs to be accessed by the use of a tool. N/A 1.7.2.6 Ozone Not such equipment. N/A 1.7.
www.tuv.com Page 11 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict P 1.7.11 Durability The label was subjected to the permanence of marking test. The label was rubbed with cloth soaked with water for 15 sec. And then again for 15 sec. With the cloth soaked with petroleum spirit. After this test there was no damage to the label. The marking on the label did not fade. There was no curling and lifting of the label edge. 1.7.
www.tuv.com Page 12 of 59 Report No.: 50261218 001 IEC 60950-1 Clause 2.1.1.7 2.1.1.8 Requirement + Test Result - Remark Verdict Discharge of capacitors in equipment P Measured voltage (V); time-constant (s).............. : Vpeak=366V, 37% of Vpeak=136V, time-constant: 0.11s ¾ Energy hazards – d.c. mains supply Connected to a.c. mains. N/A a) Capacitor connected to the d.c. mains supply .. : N/A b) Internal battery connected to the d.c. mains supply .........................................
www.tuv.com Page 13 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 2.3.2.4 Protection by other constructions ......................: N/A 2.3.3 Separation from hazardous voltages N/A Insulation employed.........................................: 2.3.4 ¾ Connection of TNV circuits to other circuits N/A Insulation employed.........................................: ¾ 2.3.5 Test for operating voltages generated externally N/A 2.
www.tuv.com Page 14 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 2.6.2 Functional earthing N/A 2.6.3 Protective earthing and protective bonding conductors N/A 2.6.3.1 General N/A 2.6.3.2 Size of protective earthing conductors N/A Rated current (A), cross-sectional area (mm2), AWG .............................................................: 2.6.3.
www.tuv.com Page 15 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Result - Remark Verdict Basic requirements The equipment relies on fuse or circuit breaker of the wall outlet protection of the building installation in regard to L to N short-circuits and earth fault condition. A build-in fuse provided as overcurrent protection device (see 5.3) P Instructions when protection relies on building installation Pluggable equipment type A. 2.7.2 Faults not simulated in 5.3.
www.tuv.com Page 16 of 59 Report No.: 50261218 001 IEC 60950-1 Clause 2.9.2 Requirement + Test Humidity conditioning Result - Remark Verdict Performed at 30 °C, 93% R.H. for 48h. P Relative humidity (%), temperature (°C) .............: See above. ¾ 2.9.3 Grade of insulation See above. P 2.9.4 Separation from hazardous voltages The adequate levels of safety insulation provided and maintained to comply with the requirements of this standard. P Method(s) used ................................
www.tuv.com Page 17 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark a) AC mains supply ......................................... : 240V a.c. and Overvoltage Category II Verdict P b) Earthed d.c. mains supplies .......................... : N/A c) Unearthed d.c. mains supplies ...................... : N/A d) Battery operation ........................................ : N/A 2.10.3.3 Clearances in primary circuits (see appended table 2.10.3 and 2.10.4) P 2.
www.tuv.com Page 18 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test 2.10.5.8 Non-separable thin sheet material 2.10.5.9 Thin sheet material – standard test procedure Result - Remark Not such material Verdict N/A N/A Electric strength test ¾ Thin sheet material – alternative test procedure (see appended table 2.10.5) P Electric strength test (see appended table 5.2) ¾ 2.10.5.11 Insulation in wound components Approved triple insulated wire used in T1. P 2.10.5.
www.tuv.com Page 19 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 2.10.8.2 Thermal conditioning N/A 2.10.8.3 Electric strength test N/A 2.10.8.4 Abrasion resistance test N/A 2.10.9 Thermal cycling N/A 2.10.10 Test for Pollution Degree 1 environment and insulating compound N/A 2.10.11 Tests for semiconductor devices and cemented joints No such devices except approved optocoupler. N/A 2.10.
www.tuv.com Page 20 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 3.2 Connection to a mains supply P 3.2.1 Means of connection See below. P 3.2.1.1 Connection to an a.c. mains supply The adaptor provided with a mains plug. P 3.2.1.2 Connection to a d.c. mains supply Only a.c. mains supply. N/A 3.2.2 Multiple supply connections Only for one mains connection. N/A 3.2.
www.tuv.com Page 21 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Rated current (A), type, nominal thread diameter (mm) ............................................................: Verdict ¾ 3.3.6 Wiring terminal design N/A 3.3.7 Grouping of wiring terminals N/A 3.3.8 Stranded wire N/A 3.4 Disconnection from the mains supply 3.4.1 General requirement See below. P 3.4.2 Disconnect devices Mains plug P 3.4.
www.tuv.com Page 22 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test 4.2 Mechanical strength 4.2.1 General Result - Remark Verdict P See below. After tests, unit complies with the requirements of sub-clauses 2.1.1 and 2.10. Rack-mounted equipment. P N/A 4.2.2 Steady force test, 10 N 10 N applied to all internal components. 4.2.3 Steady force test, 30 N No internal enclosure. 4.2.4 Steady force test, 250 N 250 N applied to outer enclosure.
www.tuv.com Page 23 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 4.3.4 Securing of parts Mechanical fixings in such a way designed that they will withstand mechanical stress occurring in normal use. P 4.3.5 Connection by plugs and sockets No mismatch of connectors either not possible or does not result in any hazard. P 4.3.6 Direct plug-in equipment See below. P Torque ......................................................... : Maximum 0.
www.tuv.com Page 24 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark 4.3.13.4 Human exposure to ultraviolet (UV) radiation ..... : 4.3.13.5 Lasers (including laser diodes) and LEDs Verdict N/A The LED is considered as indicating light. 4.3.13.5.1 Lasers (including laser diodes) P N/A Laser class ................................................... : ¾ Indicating LED on secondary is inherently exempted group according to IEC 62471. 4.3.13.5.
www.tuv.com Page 25 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test 4.6 Openings in enclosures 4.6.1 Top and side openings Result - Remark P No openings except opening of AC plug which is covered by AC plug and plug holder of top enclosure. Remaining opening <1mm. Dimensions (mm) .......................................... : 4.6.2 Bottoms of fire enclosures Verdict P ¾ No openings except one USB output. Construction of the bottom, dimensions (mm) .... : P ¾ 4.6.
www.tuv.com Page 26 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test 4.7.3.2 Materials for fire enclosures 4.7.3.3 Materials for components and other parts outside fire enclosures 4.7.3.4 Materials for components and other parts inside fire enclosures Result - Remark V-0 fire enclosure used. Verdict P N/A PCB rated V-1. See appended table 1.5.1. P Internal components except small parts are V-2 or better. 4.7.3.
www.tuv.com Page 27 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 5.1.7.1 General ........................................................ : N/A 5.1.7.2 Simultaneous multiple connections to the supply N/A 5.1.8 Touch currents to telecommunication networks and No TNV. cable distribution systems and from telecommunication networks N/A 5.1.8.1 Limitation of the touch current to a telecommunication network or to a cable distribution system N/A 5.
www.tuv.com Page 28 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict No reduction of clearance and creepage distance. Electric strength test is made on basic, supplementary and reinforced insulation after test. P 5.3.9.2 After the tests 6 CONNECTION TO TELECOMMUNICATION NETWORKS N/A 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment N/A 6.1.
www.tuv.com Page 29 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark 7.4.3 Impulse test (see appended table 5.2) A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE Verdict N/A P UL Recognized material used A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see 4.7.3.2) N/A A.1.1 Samples ....................................................... : ¾ Wall thickness (mm)...............
www.tuv.com Page 30 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict A.3.1 Mounting of samples N/A A.3.2 Test procedure N/A A.3.3 Compliance criterion N/A B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and 5.3.2) N/A B.1 General requirements N/A Position ........................................................ : ¾ Manufacturer ................................................ : ¾ Type ........................................
www.tuv.com Page 31 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict Manufacturer ................................................ : See table 1.5.1 ¾ Type ............................................................ : See table 1.5.1 ¾ Rated values ................................................ : See table 1.5.1 ¾ Method of protection .......................................: By protection circuit ¾ C.1 Overload test (see appended table 5.
www.tuv.com Page 32 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict a) Transients from a mains supply N/A For an a.c. mains supply N/A For a d.c. mains supply N/A b) Transients from a telecommunication network N/A G.6 Determination of minimum clearances .......... : N/A H ANNEX H, IONIZING RADIATION (see 4.3.13) N/A J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) N/A Metal(s) used ..............................................
www.tuv.com Page 33 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict M.3.1.2 Voltage (V) ................................................... : ¾ M.3.1.3 Cadence; time (s), voltage (V) ......................... : ¾ M.3.1.4 Single fault current (Ma) ................................. : ¾ M.3.2 Tripping device and monitoring voltage ............. : N/A M.3.2.1 Conditions for use of a tripping device or a monitoring voltage N/A M.3.2.
www.tuv.com Page 34 of 59 Report No.: 50261218 001 IEC 60950-1 Clause U Requirement + Test Result - Remark Verdict ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see 2.10.5.4) P UL listed triple insulated wire used. ¾ V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) P V.1 Introduction P V.2 TN power distribution systems P W ANNEX W, SUMMATION OF TOUCH CURRENTS N/A W.1 Touch current from electronic circuits N/A W.1.1 Floating circuits N/A W.1.
www.tuv.com Page 35 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict CC.1 General N/A CC.2 Test program 1……………………………………….: N/A CC.3 Test program 2……………………………………….: N/A DD ANNEX DD, Requirements for the mounting means of rack-mounted equipment N/A DD.1 General N/A DD.2 Mechanical strength test, variable N………………..: N/A DD.3 Mechanical strength test, 250N, including end stops……………………………………………………: N/A DD.
www.tuv.com Page 36 of 59 Report No.: 50261218 001 IEC 60950-1 Clause 1.5.1 Requirement + Test Result - Remark Verdict TABLE: List of critical components Object/part No. ManuFacturer/ trademark Type/model P Technical data Standard (Edition / year) Mark(s) of conformity 1) US plug Shenzhen Mazepower Technology Ltd. -- 100-240V~, 50/60Hz, 2A UL 1310 Tested with appliance (see attachment 1) Plug pin holder CHI MEI CORPORATION PC-6610 PC, V-0, 115°C, Min. thickness: 1.
www.tuv.com Page 37 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test CO LTD Result - Remark 100°C, X2 type Verdict E60384-14 Discharge IC (U1) On-Bright Electronics (Shanghai) Co. Ltd OB2632CP 90-264Vac, 47- Annex G.16 of 63Hz, IEC 62368-1 CX1=CX2=CX3= 0.1-0.
www.tuv.com Page 38 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark ENTERPRISE CO LTD Verdict CAN/CSA C22.2 No. 0 -Triple insulated SHENZHEN wire XINTONG WIRE CO LTD XTIW-B 130°C UL 2353, CAN/CSA C22.2 No. 210 UL E356355 Choke (LF2) SHENZHEN LUCKY TENDA ELECT RONIC CO., LTD TD1515-10mH 130°C UL 60950-1, CAN/CSAC22.2 NO.60950-1 Tested with appliance -Magnet wire TA YU UEW-H ENTERPRISE CO LTD 180°C UL 1446, CAN/CSA C22.2 No.
www.tuv.com Page 39 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark NEW MATERIALS TECHNOLOGY CO LTD Verdict C22.2 No. 0 Supplementary information: 1) Provided evidence ensures the agreed level of compliance. 1.6.2 TABLE: Electrical data (in normal conditions) P U (V/Hz) I (A) Irated (A) P (W) Fuse # Ifuse (A) 90V/50Hz -- 0.403 18.0 F1 0.403 100V/50Hz 2 0.360 18.0 F1 0.360 240V/50Hz 2 0.189 18.4 F1 0.189 264V/50Hz -- 0.163 18.
www.tuv.com Page 40 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark 90V/60Hz -- 1.011 50.2 F1 1.011 100V/60Hz 2 0.920 50.1 F1 0.920 240V/60Hz 2 0.439 50.1 F1 0.439 264V/60Hz -- 0.396 50.4 F1 0.396 90V/50Hz -- 2.013 103.6 F1 2.013 100V/50Hz 2 1.956 102.8 F1 1.956 240V/50Hz 2 0.928 100.8 F1 0.928 264V/50Hz -- 0.755 101.1 F1 0.755 90V/60Hz -- 2.043 103.5 F1 2.043 100V/60Hz 2 1.801 102.6 F1 1.
www.tuv.com Page 41 of 59 Report No.: 50261218 001 IEC 60950-1 Clause 2.5 Requirement + Test Result - Remark Verdict TABLE: Limited power sources P Circuit output tested: Note: Measured Uoc (V) with all load circuits disconnected: Components Output terminal (20Vdc, 4.5A) Test condition (Single fault) Uoc (V) Normal Isc (A) VA Meas. Limit Meas. Limit 20.2 4.66 8 92.
www.tuv.com Page 42 of 59 Report No.: 50261218 001 IEC 60950-1 Clause 2.10.3 and 2.10.4 Requirement + Test Result - Remark TABLE: Clearance and creepage distance measurements Clearance (cl) and creepage distance (cr) at/of/between: U peak (V) U r.m.s. (V) Verdict P Required cl (mm) cl (mm) Required cr (mm) cr (mm) L trace and N trace before fuse F1 (F*) 420 250 1.5 4.8 2.5 4.8 Trace of fuse F1 (F*) 420 250 1.5 2.6 2.5 2.
www.tuv.com Page 43 of 59 Report No.: 50261218 001 IEC 60950-1 Clause 4.5 Requirement + Test Result - Remark Verdict TABLE: Thermal requirements P Supply voltage (V) ....................... : Test A: 90V, 60Hz Vertical ¾ Test B: 90V, 60Hz Horizontal Test C: 264V, 50Hz Vertical Test D: 264V, 50Hz Horizontal Ambient Tmin (°C) ......................... : -- -- -- -- -- ¾ Ambient Tmax (°C) ........................ : -- -- -- -- -- ¾ Maximum measured temperature T of part/at......
www.tuv.com Page 44 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict Enclosure outside under transformer 69.1 77.3 62.9 67.5 -- 95 Ambient 25.6 25.6 25.5 25.5 -- -- Supplementary information: Temperature T of winding: -- t1 (°C) R1 (W) t 2 (°C) R2 (W) T (°C) -- -- -- -- -- Allowed Insulatio Tmax (°C) n class -- -- Supplementary information: The temperatures were measured under worst normal mode defined in 1.2.2.
www.tuv.com Page 45 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict Transformer T1 primary winding and secondary winding AC 3000 No Transformer T1 core and secondary winding AC 3000 No One layer of insulation tape AC 3000 No Note(s): The test performed immediately following the heating test as specified according to 4.5.1, 2.9.2 and 5.3 except the last item. 5.3 TABLE: Fault condition tests P Ambient temperature (°C) ........................
www.tuv.com Page 46 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test Result - Remark Verdict Q1 S-D S-C 240 1s F1 0 Fuse opened immediately, no hazard. Q1 G-D S-C 240 1s F1 0 Fuse opened immediately, no hazard. U2 Pin 1-2 S-C 240 10mins F1 0.02 Unit shutdown immediately, no damage, no hazard. U2 Pin 3-4 S-C 240 10mins F1 0.02 Unit shutdown immediately, no damage, no hazard. U2 Pin 1 O-C 240 10mins F1 0.
www.tuv.com Page 47 of 59 Report No.: 50261218 001 IEC 60950-1 Clause C.2 Loc. Requirement + Test Result - Remark Verdict TABLE: transformers T1 Tested insulation P Working voltage peak / V Working voltage rms / V (2.10.2) (2.10.2) Required Required Required electric clearance / creepage strength mm distance / mm (5.2) (2.10.3) (2.10.4) Primary to secondary RI 530 281 3000V 4.4 5.8 Core to secondary Loc. RI 530 281 3000V 4.4 5.
www.tuv.com Page 48 of 59 Report No.: 50261218 001 IEC 60950-1 Clause Requirement + Test C.2 TABLE: transformers T1 Transformer Note: pin 8 was cut off TRF No.
www.tuv.com Page 49 of 59 Report No.: 50261218 001 National Differences Clause Requirement + Test Result - Remark Verdict ATTACHMENT TO TEST REPORT IEC 60950-1 with A1:2009 and A2:2013 CANADA NATIONAL DIFFERENCES Information technology equipment – Safety – Part 1: General requirements Differences according to............. : CAN/CSA-C22.2 No. 60950-1-07, Amd 1:2011, Amd 2:2014 Attachment Form No. ................. : Attachment Originator................ : CA_ND_IEC60950_1F CSA Master Attachment ....
www.tuv.com Page 50 of 59 Report No.: 50261218 001 National Differences Clause Requirement + Test 1.7.7 Wiring terminals intended to supply Class 2 outputs in accordance with CEC Part 1 or NEC shall be marked with the voltage rating and “Class 2” or equivalent. Marking shall be located adjacent to the terminals and shall be visible during wiring. Where a fuse is used to provide Class 2, Limited Not used for such kind of Power Source, or TNV current limiting, it shall not equipment.
www.tuv.com Page 51 of 59 Report No.: 50261218 001 National Differences Clause Requirement + Test Result - Remark 3.3.3 Wire binding screws are not permitted to attach conductors larger than 10 AWG (5.3 mm2). Terminals for permanent wiring, including protective earthing terminals, are required to be suitable for US/Canadian wire gauge sizes, rated 125 percent of the equipment rating, and be specially marked when specified (1.7.7).
www.tuv.com Page 52 of 59 Report No.: 50261218 001 National Differences Clause Requirement + Test Result - Remark Verdict OTHER DIFFERENCES The following key national differences are based on requirements other than national regulatory requirements. 1.5.1 1.6.1.2 2.3.1 2.3.2.1 2.6.2 2.6.3.
www.tuv.com Page 53 of 59 Report No.: 50261218 001 National Differences Clause Requirement + Test Result - Remark 4.2.8.1 Enclosures around CRTs with a face diameter of 160 mm or more are required to reduce the risk of injury due to the implosion of the CRT. Equipment with handles complies with special loading tests. Battery packs for both portable and stationary applications are required to comply with special component requirements.
www.tuv.com Page 54 of 59 Report No.: 50261218 001 National Differences Clause Requirement + Test Result - Remark Verdict ATTACHMENT TO TEST REPORT IEC 60950-1 with A1: 2009 and A2:2013 U.S.A. NATIONAL DIFFERENCES Information technology equipment – Safety – Part 1: General requirements Differences according to.............. : UL 60950-1-07(Second Edition) + A1: 2011 + A2: 2014 Attachment Form No. .................. : US_ND_IEC60950_1F Attachment Originator ................. : UL Master Attachment ...
www.tuv.com Page 55 of 59 Report No.: 50261218 001 National Differences Clause 1.7.
www.tuv.com Page 56 of 59 Report No.: 50261218 001 National Differences Clause Requirement + Test Result - Remark Verdict Minimum cord length is 1.5 m, with certain constructions such as external power supplies allowed to consider both input and output cord lengths into the requirement N/A Flexible power supply cords are compatible with Article 400 of the NEC, and Tables 11 and 12 of the CEC N/A 3.2.9 Permanently connected equipment has a suitable wiring compartment and wire bending space 3.
www.tuv.com Page 57 of 59 Report No.: 50261218 001 National Differences Clause Requirement + Test 4.7 For computer room applications, automated Not such an application. information storage systems with combustible media greater than 0.76 m 3 (27 cu ft) have a provision for connection of either automatic sprinklers or a gaseous agent extinguishing system with an extended discharge N/A 4.7.3.1 For computer room applications, enclosures with Not such an application.
www.tuv.com Page 58 of 59 Report No.: 50261218 001 National Differences Clause Requirement + Test Result - Remark 1.6.1.2 A circuit for connection to the DC Mains Supply is classified as a SELV Circuit, TNV-2 Circuit or Hazardous Voltage Circuit depending on the maximum operating voltage of the supply No connection to the DC Mains Supply.
www.tuv.com Page 59 of 59 Report No.: 50261218 001 National Differences Clause Requirement + Test Result - Remark Verdict 6.4 Equipment intended for connection to telecommunication network outside plant cable is protected against overvoltage from power line crosses in accordance with 6.4 and Annex NAC No TNV circuits. N/A Annex EE Articulated accessibility probe (Fig EE.3) is used for Not such equipment.
Attachment 1 www.tuv.com Page 1 of 6 Report No.: 50261218 001 Plug National Deviation evaluated based on UL1310 43 - Direct Plug-In Blade Securement Test Displacement (mm) Model: MZ90PD-1 Pin holder type: PC-6610, mfr.: CHI MEI CORPORATION Blade 1 Blade 2 Grounding Pin Blade 1 and 2 0.1 0 1 -- 0.1 Note: 1) The blades did not loosen by more than 2.4 mm or pull out. 44 - Direct Plug-In Security of Input Contacts Displacement (mm) Model: MZ90PD-1 Blade 1 Blade 2 Both Blades 0.2 0.1 0.
Attachment 1 www.tuv.com Page 2 of 6 Report No.: 50261218 001 46.4 - Direct Plug-In Rod Pressure Test Model: MZ90PD-1 Rod Pressure Point Pin holder type: PC6610, mfr.: CHI MEI CORPORATION Center of enclosure face closest to transformer Voltage Touch Current (Vpk) Required? 0.1 No Note: -- Single-Phase Equipment - Figure 5a. The test was made in all combinations to the normal and reverse polarity of the supply circuit (Polarity Switch P1).
Attachment 1 www.tuv.com Page 3 of 6 Report No.: 50261218 001 7.11-Weight and moment determination: (Direct Plug-In Unit) METHOD The output cord was not included in the weight measurement. Each sample was weighed and the distance to the center of gravity was measured using suitable instruments. The distance between the center of the blades and the center of gravity was measured. The moments were then calculated by taking the products of the above measurements. W = Weight of the device.
Attachment 1 www.tuv.com Page 4 of 6 Report No.: 50261218 001 7.12 Distance from plug to accessible enclosure surface The enclosure of a unit shall be capable of being gripped for removal from the receptacle to which it is connected, and the perimeter of the face section from which the blades project shall not be less than 0.20 inch (5.1 mm) from any point on either blade A: 7.
Attachment 1 www.tuv.com Page 5 of 6 Report No.
Attachment 1 www.tuv.com Page 6 of 6 Report No.: 50261218 001 North American integrated plug according to ANSI/NEMA WD 6, FIGURE 1-15 Part No. Dimensions Limit (mm) Verdict 1.429 1.52 (TYP.) (1.393 – 1.647) P 6.23 6.10 – 6.60 P 12.7 (12.573 – 12.827) P 11.405 – 12.167 P Measurem ent (m m ) Non Polarity only A. Thickness of live pin B. Width of live pin C. Distance between two live pins (centre) 12.818 D. Distance between hole centre and plug face (if hole used) 11.579 E.
ATTACHMENT 2 Photo Documentation Page 1 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 1. External view Figure 2. External view Rev.
ATTACHMENT 2 Photo Documentation Page 2 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 3. External view Figure 4. Internal view Rev.
ATTACHMENT 2 Photo Documentation Page 3 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 5. Internal view Figure 6. PCB view Rev.
ATTACHMENT 2 Photo Documentation Page 4 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 7. Inside view of plug holder Figure 8. PCB view Rev.
ATTACHMENT 2 Photo Documentation Page 5 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 9. PCB view Figure 10. PCB view Rev.
ATTACHMENT 2 Photo Documentation Page 6 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 11. Transformer view Figure 12. Transformer view Rev.
ATTACHMENT 2 Photo Documentation Page 7 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 13. Transformer view Figure 14. Transformer view Rev.
ATTACHMENT 2 Photo Documentation Page 8 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 15. Transformer view Figure 16. Transformer view Rev.
ATTACHMENT 2 Photo Documentation Page 9 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 17. Transformer view Figure 18. Transformer view Rev.
ATTACHMENT 2 Photo Documentation Page 10 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 19. Transformer view Figure 20. Transformer view Rev.
ATTACHMENT 2 Photo Documentation Page 11 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 21. Transformer view Figure 22. Transformer view Rev.
ATTACHMENT 2 Photo Documentation Page 12 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 23. Transformer view Figure 24. Transformer view Rev.
ATTACHMENT 2 Photo Documentation Page 13 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 25. Transformer view Figure 26. Transformer view Rev.
ATTACHMENT 2 Photo Documentation Page 14 of 14 Product: Report No.: 50261218 001 USB C PD Wall Charger Type Designation: MZ90PD-1, MZ90PD-2, MZ87PD-1, MZ87PD-2, MZ65PD-1, MZ65PD-2, MZ61PD-1, MZ61PD-2, MZ45PD-1, MZ45PD-2 Figure 27. Transformer view Figure 28. Transformer view Rev.
Attachment 3 Produktsicherheit und –qualität Product Safety and Quality Page 1 of 2 Report no.: 50261218 001 Lab name: Shenzhen LCS Compliance Testing Laboratory Ltd. Instr. Instrument Instrument Range Used Make and Model Calibration Date ** Code I.D.
Attachment 3 Produktsicherheit und –qualität Product Safety and Quality Page 2 of 2 Report no.: 50261218 001 LCS-S- 0803GD42 Touch 034 Current Tester 2018/10/10 2019/10/09 LCS-S- OMEGA 061 LCS-S- Ainuo 062 Instrument Co.,Ltd.