User Manual for HF Reader DEMO V4.0 Software User Manual HF Reader Testing Demo (ISO14443A/B,MIFARE DESFire,ISO15693) (Version 1.
FCC statement This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
User Manual for HF Reader DEMO V4.0 Contents 1. Introduction............................................................................................................................................ 4 2. Operation Features...............................................................................................................................4 2.1 Hardware connection......................................................................................................................... 4 2.
User Manual for HF Reader DEMO V4.0 2.8.9.2 PICC Level-Get Application................................................................................................... 38 2.8.9.3 PICC Level-Select Application...............................................................................................39 2.8.9.4 PICC Level-Delete Application.............................................................................................. 40 2.8.9.5 PICC Level-Format PICC......................................
User Manual for HF Reader DEMO V4.0 1. Introduction This testing demo is offered for the basic functions available to operate read/write and other functions of the HF series Modules and Reader products designed by CHIKEK, and it supports of UART-TTL, RS232, RS485 and USB(COM) port products. This demo is programmed basing on C# language and run under WINDOWS system.
User Manual for HF Reader DEMO V4.0 2.
User Manual for HF Reader DEMO V4.0 2.3 2.3.1 System command Set Baudrate This function is to set according baudrate to be used in specific application. The available value is as listing and just select the right one to be set, as following show. And in the Box of Protocol Screen, there will be showing according setup command and right succeed response.
User Manual for HF Reader DEMO V4.0 2.3.2 Set LED This function is to set according LED’s working way to be used in specific application. The available value including: Lighting time: time length to be light, and the unit as 50ms No. Of Times: time cycle, which means how many times to be light during whole length And in the Box of Protocol Screen, there will be showing according setup command and right succeed response.
User Manual for HF Reader DEMO V4.0 2.3.3 Set BUZ This function is to set according buzzer’s working way to be used in specific application. The available value including: Beeping time: time length to be beeping, and the unit as 50ms No. Of Times: time cycle, which means how many times to be beeping during whole length And in the Box of Protocol Screen, there will be showing according setup command and right succeed response.
User Manual for HF Reader DEMO V4.0 2.3.4 Set ANT This function is to set which antenna to be ON or OFF when there are two antennas. (Note: The antenna’s default status is opened, and please refer to detail commands to do setup based on the Communication Protocol document for different product, or contact our technician for support) And in the Box of Protocol Screen, there will be showing according setup command and right succeed response.
User Manual for HF Reader DEMO V4.0 2.4 Auto-List Card This TAB is available to do Read all cards under 13.
User Manual for HF Reader DEMO V4.0 2.5 ISO14443A-3/4 The interface is to enable ISO14443A-3 standard cards to enter into ISO14443A-4 standard and as a contactless CPU card. 2.5.
User Manual for HF Reader DEMO V4.0 2.5.2 Send RATS RATS= Request for Answer to Select This function is to make the card quit from ISO14443A-3 enter into 14443A-4 standard, and the data returned after Send RATS, it includes the information of the testing card’s. And the response to RATS is the “Answer to Select” ATS, and the ATS consists of specified bytes for communicate between PICC capabilities and PCD. Details specific byte’s meaning, please refer to datasheet of using card.
User Manual for HF Reader DEMO V4.0 2.5.3 Send APDU This function button is a channel opened for the APDU commands, which according to different compatible commands for different cards, and please refer to them based on the cards’ datasheet.
User Manual for HF Reader DEMO V4.0 2.5.4 APDU Channel This is transfer channel to send any available commands to the card directly through RF chipset. Details commands please refer to ISO14443A-4 Standard . 2.
User Manual for HF Reader DEMO V4.0 2.6.
User Manual for HF Reader DEMO V4.0 2.6.2 MIFARE Classic-APDU Channel This is transfer channel to send any available commands to the card directly through RF chipset. Details commands please refer to ISO14443A-3 Standard .
User Manual for HF Reader DEMO V4.0 2.6.3 MIFARE Classic- Key Authenticate This is to use according KEY to authenticate for any specific Block address, Key Type and Key value. Please select the according parameter need to be used. Note: 1. The default Key value for a new MIFARE Classic 1K/4K card is FFFFFFFFFFFF when there is no change of it 2. Before each authenticate, it must to do Active card firstly and make sure without any remove card from antenna field.
User Manual for HF Reader DEMO V4.0 2.6.4 MIFARE Classic-Read Block To get to read out the data stored in the according block address.
User Manual for HF Reader DEMO V4.0 2.6.
User Manual for HF Reader DEMO V4.0 2.6.6 MIFARE Classic-Read All Blocks This is to get read out all blocks data in one time. Before enter into Read All Blocks interface, it must do Active card firstly, but no need to do Authenticate.
User Manual for HF Reader DEMO V4.0 2.6.7 MIFARE Classic-E-wallet This interface is available to do value operations directly for E-wallet function, please do according right setup for the values as below.
User Manual for HF Reader DEMO V4.0 2.7 2.7.
User Manual for HF Reader DEMO V4.0 2.7.2 Ultralight/C--APDU Channel This is transfer channel to send any available commands to the card directly through RF chipset. Details commands please refer to ISO14443A-4 Standard .
User Manual for HF Reader DEMO V4.0 2.7.3 Ultralight C Authenticate This is only opened for Ultralight C and its compatible cards which with password protected. The common MIFARE Ultralight card/tag is without password protected and no need to do it.
User Manual for HF Reader DEMO V4.0 2.7.4 Ultralight C Change Key This is only opened for Ultralight C and its compatible cards which with password protected. And please do Authenticate with old KEY before Change Key. The data length for the KEY value is 16bytes.
User Manual for HF Reader DEMO V4.0 2.7.5 Ultralight /C Read Page To get to read out the data stored in the according page address. And For MIFARE Ultralight C and its compatible cards, And NTAG 2xx series card before Read Page, Authenticate is needed firstly and make sure no remove of card after Active card. If there any remove, please again as Active-IDLE/Active-ALL --> Authenticate then Read Page with optional Page Address, as below: For common MIFARE Ultralight card, Authenticate is no need.
User Manual for HF Reader DEMO V4.0 2.7.6 Ultralight /C Write Page To Write the requested data into the according page address. And For MIFARE Ultralight C and its compatible cards, And NTAG 2xx series card Before Write Page, Authenticate is needed firstly and make sure no remove of card after Active card. If there any remove, please again as Active-IDLE/Active-ALL --> Authenticate then Write Page to optional Page Address, as below: For common MIFARE Ultralight card, Authenticate is no need.
User Manual for HF Reader DEMO V4.0 2.8 2.8.
User Manual for HF Reader DEMO V4.0 2.8.2 DESFire Card-RATS RATS= Request for Answer to Select And the response to RATS is the “Answer to Select” ATS, and the ATS consists of specified bytes for communicate between PICC capabilities and PCD. Details specific byte’s meaning, please refer to datasheet of using card. Note: Before RATS, Active-IDLE/Active-ALL is needed firstly.
User Manual for HF Reader DEMO V4.0 2.8.3 DESFire Card-Get Version To get the returned manufacturing related data of the DESFire cards Note: Active-IDLE/Active-ALL-->>RATS is needed before Get Version.
User Manual for HF Reader DEMO V4.0 2.8.4 DESFire Card-Get Key Version The Get Key Version command allows to read out the current key version of any key stored on the card.
User Manual for HF Reader DEMO V4.0 2.8.5 DESFire Card- Key Authenticate This procedure is not only confirm that both card/tag and reader device can trust each other, but also generates a session key which can be used to keep the further communication path secure. Note Master Keys are identified by their key number 0x00, this is valid on PICC level (selected AID=0x00) and on Application Level.
User Manual for HF Reader DEMO V4.0 2.8.6 DESFire Card- Get Key Setting This function command allows to get configuration information on the card/tag and application master key configuration setting. It returns the maximum number of keys which can be stored within the selected application. Before Get Key Setting, a proceeding authentication with the master key is required.
User Manual for HF Reader DEMO V4.0 2.8.7 DESFire Card- Change Key Setting This command changes the master key configuration setting depending on the currently selected AID. This command takes one byte as parameter which codes the new master key settings., details configuration changeable bits, please refer to detail datasheet of using card. Authenticate is needed before Change Key Setting.
User Manual for HF Reader DEMO V4.0 2.8.8 DESFire Card- Change Key This command allows to change any key stored on the card/tag.
User Manual for HF Reader DEMO V4.0 2.8.9 DESFire Card- PICC Level This interface is for PICC application operations.
User Manual for HF Reader DEMO V4.0 2.8.9.1 PICC Level-Create Application This command allows to create new application on the PICC Parameters to be operated: Application ID(AID): Key Setting: 24 bit number=0x00 00 00 and reserved as reference to the PICC itself Application Master Key Setting as defined in Chapter 2.8.
User Manual for HF Reader DEMO V4.0 2.8.9.2 PICC Level-Get Application To Get the Application ID or IDs stored in the card.
User Manual for HF Reader DEMO V4.0 2.8.9.