User's Manual

Wireless In/Out Thermometer with Remote
Thermo Sensor
Item : 801.942.00 / 801.942.00T
USER MANUAL
INTRODUCTION
Thank you for selecting this IKEA In/Out
Thermometer. Please keep this manual handy
as you use your new product. It contains
practical instructions, technical specifications
and warnings you should know about.
THERMOMETER OVERVIEW
FRONT VIEW (FIG 1)
1. Indoor temperature
2. Outdoor temperature
3. Sensor reception icon
BACK VIEW (FIG 2)
1. Battery compartment
2. Wall mount hole
3. RESET:
Reset unit to default settings
4. °C / °F:
Select temperature unit
REMOTE SENSOR (FIG 3)
1. LED status indicator
2. Wall mount hole
3. Battery compartment
4. RESET hole to reset the unit
5. CHANNEL button: Change channels
FIG. 1
FIG. 2
FIG. 3
FIG. 4
GETTING STARTED
INSERT BATTERIES
1. Slide battery compartment open and insert
batteries, matching polarities (see FIG. 2).
2. Press RESET after each battery change.
3. Place main unit using a table or wall stand
(see FIG 4) within 30m (98 ft) of the sensor.
REMOTE SENSOR (
To set up the sensor:
Slide battery compartment open and insert
batteries, matching polarities (see FIG. 3).
Place the sensor within 30 m (98 ft) of the main
unit using the table stand or wall mount (see
FIG 4).
The transmission range may vary depending on
many factors. You may need to experiment with
various locations to get the best results.
NOTE We recommend that you use alkaline
batteries with this product for longer usage and
consumer grade lithium batteries in
temperatures below freezing.
SENSOR DATA TRANSMISSION
To search for a sensor:
The main unit will automatically search for a
signal from the remote sensor.
The sensor reception icon in the remote
sensor area shows the status:
ICON DESCRIPTION
Main unit is searching for
sensor(s)
A sensor has been found
Sensor 1 data received
and “--.-
The sensor cannot be
found
NOTE If the sensor is not found, check the
batteries, obstructions, and remote unit
location.
For best results:
Place the sensor out of direct sunlight and
moisture.
Position the sensor facing the main unit,
minimizing obstructions.
Place the sensor in a location with a clear
view to the sky, away from metallic or
electronic objects.
Position the sensor close to the main unit
during cold winter months.
TEMPERATURE UNIT
Press °C / °F to change the temperature unit.
RESET
Press RESET to return to the default settings.
PRECAUTIONS
Do not subject the unit to excessive force,
shock, dust, temperature or humidity.
Do not cover the ventilation holes with any
items such as newspapers, curtains etc.
Do not immerse the unit in water. If you spill
liquid over it, dry it immediately with a soft,
lint-free cloth.
Do not clean the unit with abrasive or
corrosive materials.
Do not tamper with the unit ’s internal
components. This invalidates the warranty
Only use fresh batteries. Do not mix new
and old batteries.
Images shown in this manual may differ
from the actual display.
When disposing of this product, ensure it is
collected separately for special treatment.
The contents of this manual may not be
reproduced without the permission of the
manufacturer.
Do not dispose old batteries as unsorted
municipal waste. Collection of such waste
separately for special treatment is
necessary.
Please note that some units are equipped
with a battery safety strip. Remove the strip
from the battery compartment before first
use.
NOTE The technical specifications for this
product and the contents of the user manual
are subject to change without notice.
SPECIFICATIONS
TYPE DESCRIPTION
MAIN UNIT (801.942.00)
L x W x H 70 x 59 x 23 mm
(3.11 x 2.33 x 0.91 in)
Weight 241 g (8.5 oz)
without battery
Operating
Temperature range
-5°C to 50°C
(23°F to 122°F)
Temperature range
Resolution 0.1°C (0.2°F)
Signal frequency 433 MHz
Power 2 x UM-4 (AAA) 1.5 V
batteries
REMOTE UNIT (801.942.00T)
L x W x H 96 x 50 x 22 mm
(3.8 x 2.0 x 0.9 in)
Weight 62 g (2.22 ounces)
Transmission range 30 m (98 ft) unobstructed
Operating
Temperature range
-30°C to 60°C
(-22.0°F to 140°F)
Power 1 x UM-3 (AA) 1.5 V
batteries
EU-DECLARATION OF CONFORMITY
Hereby, we declares that this model:
801.942.00 and 801.942.00T are in compliance
with the essential requirements and other
relevant provisions of Directive 1999/5/EC. A
copy of the signed and dated Declaration of
Conformity is available on request via our
Customer Service.
COUNTRIES RTT&E APPROVED COMPLIED
All EU countries, Switzerland and Norway
FCC STATEMENT
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) This device must
accept any interference received, including
interference that may cause undesired
operation.
WARNING Changes or modifications not
expressly approved by the party responsible for
compliance could void the user's authority to
operate the equipment.
NOTE This equipment has been tested and
found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can
radiate radio frequency energy and, if not
installed and used in accordance with the
instructions, may cause harmful interference to
radio communications. However, there is no
guarantee that interference will not occur in a
particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning
the equipment off and on, the user is
encouraged to try to correct the interference by
one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the
equipment and receiver.
Connect the equipment into an outlet on a
circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio /
TV technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as
contact for support or sales. Please call our
customer service number for all inquiries
instead.
We
Name: Oregon Scientific, Inc.
Address: 19861 SW 95
th
Ave.,Tualatin,
Oregon 97062 USA
Telephone No.: 1-800-853-8883
declare that the product
Product No.: 801.942.00 / 801.942.00T
Product Name: Wireless In/Out Thermometer
Manufacturer: IDT Technology Limited
Address: Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
is in conformity with Part 15 of the FCC Rules.
Operation is subject to the following two
conditions: 1) This device may not cause
harmful interference. 2) This device must
accept any interference received, including
interference that may cause undesired
operation.

Summary of content (1 pages)