ILR 350 Series i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS Installation and Operation Manual
RTLS Hardware and Installation Manual Proprietary Notice This document contains confidential information proprietary to IDENTEC SOLUTIONS and may not be used or disclosed to other parties in whole or in part without prior written authorization from IDENTEC SOLUTIONS.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS Radio Frequency Compliance Statement IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices: MODEL: Region/Country EUROPE: USA: Canada: MODEL: Region/Country EUROPE: USA: Canada: MODEL: Region/Country EUROPE: USA: Canada: Organization EC FCC Industry Canada i-PORT M 350 Marking CE FCC ID OO4-ILR-IPM350N IC:3538A-IPM350N Organization EC FCC Industry Canada i-SAT 300 RTLS Marking CE FCC ID OO4-ILR-ISAT300 IC:3538A-ISAT300 Or
RTLS Hardware and Installation Manual European Notification according R&TTE Directive This equipment complies to Art. 6.4 of R&TTE Directive (1999/5/EC). It is tested for compliance with the following standards: ETSI EN 300 220, ETSI EN 300 440, ETSI EN 301 489, EN 60950. USA Notification This device complies with part 15 of the FCC Rules.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS This product contains components that are sensitive to electrostatic discharges. Please observe the special instructions for their protection. Incorrect handling can damage the unit and cause the invalidation of the warranty. Minimum safety precautions against electrostatic discharge: • Establish earth contact bef ore you touch the unit. For example, touch the earthing scr ew on the unit.
RTLS Hardware and Installation Manual Contents 1 INTRODUCTION ...........................................................................................................7 1.1 1.2 2 FEATURES .................................................................................................................. 7 DOCUMENTS OVERVIEW ................................................................................................. 8 MECHANICAL INSTALLATION ..........................................................
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS 1 Introduction The RTLS system is the newest development in IDENTEC SOLUTIONS’ Intelligent Long Range® (ILR®) interrogators. ILR provides highly accurate, real-time data collection with minimal human intervention. The very long communication range of up to 500 m (1500 ft) allows automated identification, tracking and tracing of assets and people in areas as large as a steel construction workshop without human intervention.
RTLS Hardware and Installation Manual 1.2 Documents Overview Manuals IM.0710.DE IM.0710.EN IM.0711.DE IM.0711.EN IM.0712.DE IM.0712.EN IM.0713.DE IM.0713.DE IM.0714.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS 2 2.1 Mechanical Installation Hints Mounting Kit DIN Rail Clamp Mounting Kit with DIN Rail Clamp The i-PORT M 350 RTLS is plugged into the mounting kit. Between the mounting kit and the reader module there is 5 mm space left for the screws. It is intended to always use the mounting kit. If mounting on a DIN rail is desired, the additional clamp is mounted on the rear side of the mounting kit.
RTLS Hardware and Installation Manual 2.
144 i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS 67,3 36,5 Dimensions with end cap (cable inlet protection), but without mounting kit Page 11 of 30
RTLS Hardware and Installation Manual 3 Electrical Installation 3.1 Safety Instructions • The power supply circuit must comply with the requirements of the SELV circuits (see EN 60950). • The signal circuits must comply with the requirements of the SELV circuits (see EN 60950).
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS 3.3 Overview Position Server Ethernet or RS422 (i-BUS) i-PORT M 350 RTLS i-BUS i-PORT M 350 RTLS i-BUS i-PORT M 350 RTLS Central Power Supply 3.4 Power Supply The i-PORT M 350 RTLS is powered by the i-BUS. Total Power Consumption—i-PORT M 350 RTLS with 4 i-SAT 300 RTLS 1 × i-PORT M 350 RTLS, app. 2 W 4 × i-SAT 300 RTLS, app. each 2 W This gives a maximum sum of 7 W of power consumption. 3.
RTLS Hardware and Installation Manual 3.6 The i-BUS Connector Please Note • The i-BUS uses RS422 lev els on its RX and TX Pins, although Ethernet jack/plugs mechanically fit, the device is not Ethernet compatible. • As the TxD/RxD cr ossing is done by the pinout of the connectors, simple str aight cabling can be used. • If devices are powered by the RJ45 cabling of th e i-BUS , wir e gauge must be at least A WG24 (0.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS 3.7 Ethernet Connector The Ethernet interface is an option for an i-PORT M 350 RTLS. Warning Do not connect any device to your network before it has been configured. Before connecting to your network, check that the desired IP address has been set. A not-configured device may have any IP address. A device with the wrong settings may impede the functioning of your network. Ethernet interface with 10 or 100Mbit/s.
RTLS Hardware and Installation Manual 4 Initial Operation 4.1 Checking the Installation After completing the installation the operation must be systematically checked. The installation check can be divided into three sections: • Visual test • Basic operational check • Detailed operational check If the basic check of the operational behavior is to be carried out using a (portable) PC a final check via the intended user control system should also be carried out. 4.2 Configuration 4.2.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS 4.
RTLS Hardware and Installation Manual Select “Network Protocol (TCP/IP) and click on “Properties”. Check if both checkboxes “Obtain … automatically” are checked. Confirm with “OK”.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS Discover the i-PORT’s Ethernet Interface • Connect the PC with the i-PORT. • Start the software “Device Discovery Utility”. This software will automatically detect the Ethernet device of the i-PORT. • Select the device listed, then chose “Device Tasks” => “Open Web Interface”. Now the standard web browser on the PC should start, opening the IP address of the Ethernet device.
RTLS Hardware and Installation Manual Configuration of the Internal Communication In the category “Configuration” select “Serial Ports”. Click on “Change Profile”.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS In this list chose “TCP Sockets” and confirm with “Apply”.
RTLS Hardware and Installation Manual Check the port settings and correct if necessary. Now go on with the “Basic Serial Settings”. Adjust them to this parameters and confirm.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS This is the last step of the port configuration. Set the TCP Settings to the values shown. Then confirm with “Apply”.
RTLS Hardware and Installation Manual Users Configuration In order to change the password for the user “root” click on the user name and fill in the fields with the old and new password. The new password needs to be typed twice to prevent typos.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS Network Configuration Important Note As the connection to the Ethernet device will probably be lost, after the network configuration it is recommended to do this as the last step of configuration. In the category “Configuration” chose “Network” and change to the “Advanced Network Settings”. Here you can give the i-PORT a useful name for identification in the network. Confirm with “Apply”.
RTLS Hardware and Installation Manual In the category “Configuration” chose “Network”. Now adjust the network settings as required. Then finish by click on “Apply”. Finally, in the category “Administration” choose “Reboot”. 4.4 Status Display (LEDs) ANT 1: This is the antenna of the 2.45 GHz RTLS part. LED blinks green when a valid packet has been received. It blinks RED when a ranging of type 1 has been successfully done. ANT 2: This is the antenna of the UHF part.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS 5 Maintenance 5.1 General In principle, the ILR system is maintenance-free. When correctly installed it operates for many years without any problems. 5.2 Precautionary Maintenance Regular checking of all ports and cables belonging to the system is recommended. Unstable connections could lead to damage and malfunctions of the system and therefore should be repaired as soon as possible.
RTLS Hardware and Installation Manual 5.3 5.3.1 Spare Parts Recommended spare parts stock In order to keep the down time of the system during malfunctions as short as possible it is recommended to have certain spare parts in stock. At least one central unit, one antenna and one antenna cable should be available. With larger systems with more than approx. 15 i-PORTs the doubling of the recommended stock quantity should be considered.
i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS 6 Technical Data Operating Data Long-Range RFID (ILR, 2400 – 2485 MHz ISM Band) Read/write/localization range Channels Data rate Maximum transmission power Standards/Certification Compatibility Up to 180 m (590 ft) in free air with line of sight 3 Non-Overlapping channels (for EU and US) or 7 Overlapping channels 250 kbits/s and 1 Mbits/s 100 mW EIRP or local regulation ISO 24730 part 5 (upcoming standard), FCC part 15, EN 300 328 (EU) i-Q350 RTLS series t
RTLS Hardware and Installation Manual Physical Dimensions Case Material Mass Enclosure rating Page 30 of 30 97 × 67 × 97 mm (3.8 × 2.6 × 3.8 in.) 153 × 67 × 97 mm (6.0 × 2.6 × 3.8 in.) incl. cover Plastic 150 grams (5.