MorphoAccess® SIGMA Lite Series Installation Guide COPYRIGHT© 2015 Morpho Osny, France MorphoAccess® SIGMA Lite Series – Installation Guide 2015_2000007248-V1 - Draft June 2015
MorphoAccess® SIGMA Lite Series – Installation Guide Warning Warning COPYRIGHT© 2015 Morpho. All rights reserved. Information in this document is subject to change without notice and do not represent a commitment on the part of Morpho. This document contains information of a proprietary nature to Morpho and is submitted in confidence for a specific purpose.
MorphoAccess® SIGMA Lite Series – Installation Guide Revision History Revision History The table below contains the history of changes made to the present document. Version Date Reference 01 June 2015 2015_0000007248-V1 - Draft 2015_2000007248-V1 - Draft June 2015 Description Document creation This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Table of Content Table of Content Warning ........................................................................................................................................ 2 Revision History ............................................................................................................................ 3 Section 1 : Introduction ............................................................................................................
MorphoAccess® SIGMA Lite Series – Installation Guide Table of Content Nominal characteristics of switch block .............................................................................. 34 Wiegand port wiring ............................................................................................................... 35 Wiegand input wiring .......................................................................................................... 35 Wiegand output wiring ...............................
MorphoAccess® SIGMA Lite Series – Installation Guide Table of Content Areas containing combustibles............................................................................................ 57 Specific precautions for terminals equipped with a contactless smartcard reader ............ 57 Ethernet connection ............................................................................................................ 57 Date / Time synchronization ............................................................
MorphoAccess® SIGMA Lite Series – Installation Guide Table of Figures Table of Figures Figure 1: Implementation Recommendations .............................................................................15 Figure 2: Box Opening..................................................................................................................18 Figure 3: Box Content ..................................................................................................................
MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Section 1 : Introduction 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction MorphoAccess® SIGMA Lite Series terminals Congratulations for choosing a MorphoAccess® SIGMA Lite Series Automatic Fingerprint Recognition Terminal. MorphoAccess® SIGMA Lite Series provides an innovative and effective solution for access control applications using Fingerprint Verification or/and Identification.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Scope of the document This guide deals with the installation of MorphoAccess® SIGMA Lite Series, which is made up of following list of products: MA SIGMA Lite Series Contactless smartcard reader Biometrics Marketing Name iCLASS MA SIGMA Lite MA SIGMA Lite iClass MA SIGMA Lite Multi MA SIGMA Lite Prox MA SIGMA Lite+ MA SIGMA Lite+ iClass MA SIGMA Lite+ Multi MA SIGMA Lite+ Prox ® Water Resistan
MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Safety Instructions means Direct Current (DC) The installation of this product should be made by a qualified service Person and should comply with all local regulations. It is strongly recommended to use a class II power supply at 12VDC-24VDC and 1A minimum (at 12VDC) in conformity with Safety Electrical Low Voltage (SELV). The power supply cable length should not exceed 10 meters.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Regulations Europe information MorphoAccess® SIGMA Lite Series are intended to be used for professional application only (buildings, airport...). Residential usage isn’t on application domain of these products. Morpho hereby declares that the MorphoAccess® SIGMA Lite Series terminal has been tested and it complies with following listed standards: EMC Directive 2004/108/CE – Class A R&TTE Directive (1999/5/CE).
MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Consult the dealer or an experienced radio/TV technician for help. Shielded cables must be used with this unit to ensure compliance with category B FCC restrictions. Canada information WARNING TO USERS IN THE CANADA / ATTENTION POUR LES UTILISATEURS AU CANADA This device complies with Industry Canada license-exempt RSS standard(s), and with ICES 003 standard for version(s) without RFID reader.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction Recommendations for terminal implementation Every installation is unique. Sometimes the issues are well defined and can be handled in a standard fashion; sometimes the issues are very specific and may not be immediately recognizable.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction To secure properly an access, Morpho recommends installing the MorphoAccess® SIGMA Lite Series terminal as a part of the typical Access Control environment, as the one described in the figure below.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 1 : Introduction The individuals who are authorized to access the secured area have their User ID listed in a so-called "White List" (in contrast with a black list). The MorphoAccess® SIGMA Lite Series terminal and the Controller are communicating using one of the available protocol (TCP/IP, Wiegand or Dataclock, or RS485).
MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Section 2 : General Description 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Box opening At the box opening, components shall be extracted from the protection casing as depicted in the pictures below. Extract the wall plate (which is not screwed to the terminal) and keep it separate until the installation of the terminal is completed. The screwing of the product to the wall plate is the last stage of the installation.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Components of the initial package Figure 3: Box Content 1. One (1) Terminal’s body 2. One (1) Wall frame 3. One (1) Pre-wired back door 4. One (1) Protection accessory (optional) to insert over the biometric sensor 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Terminal's front view description USB port (for configuration and settings with a USB mass storage) Buzzer 2.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Terminal's rear view description USB port (for installation of an optional Wi-Fi™ USB dongle) RJ-45 female connector Internal Relay Terminal blocks Anti-tamper / Antipulling switches Wiegand or Data & Clock RS485 & GPIO Power supply & Tamper Switch Figure 5: MorphoAccess® SIGMA Lite Series terminal rear view 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description MorphoAccess® SIGMA Lite Series Technical Characteristics Item Description Access control modes Identification (search for fingerprint in a local database) Authentication with contactless smartcard, with or without fingerprint check (only if terminal is equipped with a contactless smartcard reader) Multi-factor: identification or authentication (only if terminal is equipped with a contactless smartcard reader) Proxy: th
MorphoAccess® SIGMA Lite Series – Installation Guide Section 2 : General Description Serial port The serial port supports WIEGAND, DATACLOCK (ISO2) and RS485 protocols Output relay switches Access granted: 1 switch two outputs (normally “open” and normally “closed”) (30V – 2A max) USB host port External port for terminal configuration through a USB mass storage key Internal port to connect an external Wi-Fi™ USB dongle using an adapter cable.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 3 : Installation Procedure Section 3 : Installation Procedure 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 3 : Installation Procedure Before proceeding to the installation Make sure that you have all the components described in “Components of the initial package” section at your disposal. Remove the wall plate. Keep this element at hand. Figure 6: Removing wall frame It is then possible to fix wall plate on the wall. The recommended height for fixing of the terminal is 1.40m (top of the product).
MorphoAccess® SIGMA Lite Series – Installation Guide Section 3 : Installation Procedure Installation Required tools (not supplied) Two (2) raw plugs + Two (2) ø 4mm max and length 30mm screws. One (1) screwdriver adapted to screws above. One (1) Drill (with a drill bit diameter adapted to raw plugs above). One (1) hole saw (depending on installation case).
MorphoAccess® SIGMA Lite Series – Installation Guide Section 3 : Installation Procedure Step by step procedure The recommended height for fixing of the terminal is 1.40m (top of the product). For an optimal use the terminal must be installed in an area where the lighting conditions are controlled. Avoid direct exposure of the sensor to the sun light. Power supply from electrical source shall be switched off before starting the installation.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 3 : Installation Procedure If not present, drill in the wall a hole with a diameter adapted to the width of the terminal and the cable to be hosted in (see Figure 7: Drilling template. This template at scale 1:1 can be found in the Quick Installation Guide).
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Section 4 : Electrical Interface 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Wiring overview Before proceeding, make sure that the person in charge of installation and connections is properly connected to earth, in order to prevent Electrostatic Discharges (ESD). Power supply ground shall not be used for peripheral ground. All other grounds can be used indifferently.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Power Supply POE and external power supply can be used simultaneously, but when both power supplies are available, priority is given to external power supply. If the external power supply fails or is shut down, the terminal will go off and then restart using POE.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Output Relay Figure 11: Output relay wiring 19 Yellow Relay NO Contact relay (normally open) 22 Grey Relay COM Contact relay common 21 Orange Relay NC Contact relay (normally closed) Nominal characteristics of relay Load characteristics: 1 A max @ 30 VDC (according to the safety extra low voltage requirements independently of the power supply), Resistive load or inductive load; see warning information
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Example of connection for electrical door locks + VCC <30V Imax < 2A Overswing diode MorphoAccess® SIGMA Terminal Electric door lock Relay Pin 1 Relay Pin 2 Button on other side of the door Figure 12: Example of electric latch connection 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Tamper Switch Figure 13: Tamper switch wiring 3 Light Blue Switch 1 Tamper switch contact 4 Pink Switch 2 Strip on tamper switch Operating principle for the switch Product installed on the wall plate: switch enabled (contact closed). Product opened (rear connectors accessible): switch disabled (contact open).
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Wiegand port wiring Wiegand input wiring The following figure shows how to cable the wires of the “Wiegand In” port of the terminal for Wiegand protocol. This is used, for instance, to connect an external card stripe reader to the MorphoAccess® SIGMA Lite terminal.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Wiegand output wiring The following figure shows how to cable the wires of the Wiegand OUT port of the terminal for Wiegand protocol. This is used, for instance, to connect the MorphoAccess® SIGMA Lite terminal to an Access Control Panel (ACP).
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface The controller supports neither LED1 nor LED2 signals When the access controller has no relay contact to provide an answer to the MorphoAccess® terminal, then the decision to emit either the “access granted” signal or the “access denied” signal is taken by another way.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Data Clock Input The following figure shows how to cable the wires of the “Wiegand In” port of the terminal for Data Clock protocol. This is used, for instance, to connect an external card stripe reader to the MorphoAccess® SIGMA Lite terminal.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Data Clock Output The following figure shows how to cable the wires of the Wiegand OUT port of the terminal for Data Clock protocol. This is used, for instance, to connect the MorphoAccess® SIGMA Lite terminal to an Access Control Panel (ACP).
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface RS-485 port wiring The following figure shows how to cable the wires of the RS-485 OUT port of the terminal (RS-485 protocol). This is used, for instance, to connect the MorphoAccess® SIGMA Lite terminal to an Access Control Panel (ACP).
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface GPIO wiring Figure 19: GPIO wiring 9 Orange GPI_0 In Digital Input (1,8V to 5V) 10 Orange / Red GPI_1 In Digital Input (1,8V to 5 V) 11 Yellow GPO_0 Out Digital Output (5V – 5mA max) 12 Yellow / Red GPO_1 Out Digital Output (5V – 5mA max) 8 Black / Red GPIO_GND 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Single Door Access Control (SDAC) implementation Push button / Motion sensor External Power supply RELAY_COM RELAY_NO/NC Door strike GPI_0 GPO_0 GPI_1 GPO_1 Door contact Figure 20: SDAC wiring If door contact is not used, GPI1 and GPO1 shall be connected together 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Ethernet connection Ethernet interface can be used to power the MorphoAccess® SIGMA Lite Series terminal through POE (Power Over Ethernet - IEEE802.3af or IEEE802.3at type 1 mode). According to the POE standard two modes are available: power on data pins and power on dedicated pins. Use either one of these modes depending on POE implementation on your local Ethernet network.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface External USB connection Figure 22: External USB connection The external Micro USB port can be used to connect a mass storage USB key for administration only. This requires a standard Micro USB-type A / USB-type A female adapter or cable (which can be found in Morpho catalogue with ref 293658551). Please report to MorphoAccess® SIGMA Lite Series Administration Guide for more information.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 4 : Electrical Interface Wi-Fi™ dongle installation Wi-Fi™ dongle shall be preferably installed outside the product (separate area shall be reserved in the wall) and connected to the internal USB Mini B (at the rear of the terminal) using Morpho cable provided in the kit. Wi-Fi™ dongle shall not be exposed to temperature exceeding 50°C (don’t forget to count the thermal dissipation of the product and of the Wi-Fi™ dongle).
MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface Section 5 : User Interface 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface Modes for controlling access rights Introduction The MorphoAccess® SIGMA Lite Series terminal offers several methods for controlling access rights: it needs to be configured in one of the following four modes: Identification mode, Authentication mode (requires a contactless smartcard reader in the terminal), Multi-factor mode (requires a contactless smartcard reader in the terminal), Proxy mode Refer to MorphoAccess® SI
MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface For further information, please see the "Authentication mode" section in the MorphoAccess® SIGMA Lite Series Administration Guide.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface the terminal. Once the template request is posted to the external database, the terminal shall wait for the finger template from the external database to start authentication. Further process shall be same as authentication. Polling Process using buffer: The user’s input ID will be queued in the terminal’s queue, which is polled by external application. External application waits for the User ID by polling the buffer.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface Configuring the terminal MorphoAccess® SIGMA Lite Series terminals are standalone biometric systems which offers advance features for access control. MorphoAccess® SIGMA Lite Series terminals are equipped with a facility to support the MorphoAccess® and Bioscrypt legacy systems.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface Configuration procedures are described inside the MorphoAccess® SIGMA Lite Series Administration Guide as follows: Section 4: Terminal Configuration And Administration MorphoAccess® SIGMA Lite Series native mode MorphoAccess® SIGMA Lite Series terminal is by default configured in native mode, also named MA5G. It will support the new features and configurations only in the native mode.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 5 : User Interface Anti-tamper / anti-pulling switches Please refer also to “Tamper Switch” section. These switches are activated as soon as there is enough pressure applied on the terminal against the wall. They are deactivated as soon as this pressure is not big enough, e.g. when the terminal is pulled out of the wall.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 6 : Accessories, Software Licenses and PC Applications Section 6 : Accessories, Software Licenses and PC Applications 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 6 : Accessories, Software Licenses and PC Applications Compatible Accessories, Licenses and Software The following items can be ordered directly to Morpho or to an official distributor, so as to enjoy all the features of your MorphoAccess® SIGMA Lite Series terminal: Power supply units, Contactless smartcards: MIFARE® 1k, 4k; DESFire® 2k, 4k, 8k, MA WI-FI PACK: containing a Wi-Fi™ USB dongle and a Wi-Fi™ license to activate Wi-Fi™ capabilit
MorphoAccess® SIGMA Lite Series – Installation Guide Section 6 : Accessories, Software Licenses and PC Applications Compatible PC applications MorphoAccess® SIGMA Lite Series terminals are fully compatible with: Morpho Integrator’s Kit (MIK) software development kit (version 6 or later). MorphoBioToolBox (version 2 or later) Using Legacy Morpho mode, MorphoAccess® SIGMA Lite Series is also compatible with: MEMS (version 7.3.1 or later), MIK (version 5.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 7 : Recommendations Section 7 : Recommendations 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 7 : Recommendations Notice The manufacturer cannot be held responsible in case of non-compliance with the following recommendations or incorrect use of the terminal. General precautions Do not attempt to repair your terminal yourself. The manufacturer cannot be held responsible for any damage/accident that may result from attempts to repair components. Any work carried out by non-authorized personnel will invalidate your warranty.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 7 : Recommendations operating temperatures), deviation may be more important (worst case: - 14 seconds per 48 hours). If the terminal is used in an application requiring high time precision, we recommend synchronizing regularly your terminal time with an external clock (using NTP). Every 24 hours is usually enough for most applications. Please note that the date/time of the terminal is protected from power failure during at least 24 hours.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 7 : Recommendations Ethernet communication 4G Lite Series MA-J Series RJ45 connector or wires MA SIGMA Lite Series Block connector RJ45 connector RJ45 connector or wires Serial communications Wiegand 4G Lite Series MA-J Series MA SIGMA Lite Series Yes Interfaces multiplexed on the same lines.
MorphoAccess® SIGMA Lite Series – Installation Guide Section 7 : Recommendations RELAY Relay pins available Driver capability 4G Lite Series MA-J Series MA SIGMA Lite Series NO / NC / COM* NO / COM NO / NC / COM 1 A @30V DC 1 A @30V DC 1 A @30V DC (Resistive load) (Resistive load) (Resistive load) *: NO: Normally open NC: Normally closed COM: Common RS232 communication 4G Lite Series MA-J Series MA SIGMA Lite Series Not available Not available Not available Anti theft/ Tamper switches 4
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Annex 1 : Finger Placement Recommendations 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Main principles Acquisition needs to be done with extreme care, in order to: get the best image quality increase recognition performance reduce recognition time Then, it is highly recommended to: Maximize the contact between the fingerprint and the sensor Exert firm, but not excessive, finger pressure on the surface of the sensor Do not press too hard Do not slide nor roll the finger across the sen
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Most useful areas for biometric data Fingerprint central area must be aligned with sensor center. Area containing the maximum information 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Position of finger Finger height Align center of 1st phalanx with sensor center Finger angle The finger must be parallel to sensor sides IDEAL POSITION 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Finger inclination Finger must be parallel to the sensor surface IDEAL POSITION Finger rotation Finger must be parallel to the sensor surface IDEAL POSITION 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 1 : Finger Placement Recommendations Troubleshooting When finger biometric data recommendations listed below: acquisition is difficult, please follow the The finger is cold o Solution : warm up the finger The finger is wet o Solution : wipe the finger The finger is dry o Solution : warm up the finger and/or add a little bit of humidity The finger is dirty o Solution: wash hands Remove bandages or adhesive tapes from the fingerprint
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 2 : Bibliography Annex 2 : 2015_2000007248-V1 - Draft June 2015 Bibliography This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 2 : Bibliography How to get the latest versions of documents The last version of the documents can be downloaded from our web site at the address below: www.biometric-terminals.com (Login and password required to allow access to the private part). To request a login, please contact your sales representative. 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 2 : Bibliography Documents concerning the MorphoAccess® terminal Documents about installing the terminal MorphoAccess® SIGMA Lite Series Installation Guide, Ref. 2015_0000007248 This document describes terminal physical mounting procedure, electrical interfaces and connection procedures. This document is in English. Documents about administrating / using the terminal MorphoAccess® SIGMA Lite Series Quick User Guide, Ref.
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 2 : Bibliography Release note For each firmware version, a release note is published describing the new features, the supported products, the potential known issues, the upgrade / downgrade limitations, the recommendations, the potential restrictions… 2015_2000007248-V1 - Draft June 2015 This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 3 : Support Annex 3 : 2015_2000007248-V1 - Draft June 2015 Support This document and the information therein are the property of Morpho.
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 3 : Support Troubleshooting The terminal IP address is unknown or it is not possible to connect to the terminal Load a valid set of network parameters in your terminal. The sensor is switched off Check that the database contains at least one record. Check that the identification mode is enabled. The terminal returns erratic responses to Ping commands Check the subnet mask. Ask the network administrator for the correct value.
MorphoAccess® SIGMA Lite Series – Installation Guide Annex 3 : Support Technical Support and Hotline North America Mail: cscenter@morpho.com Tel: +1 888 940 7477 South America Mail: cscenter@morpho.com Tel: +1 714 575 2973 South Africa Mail: sec.san.bio.support@morpho.com Tel: + 27 11 286 5855 India: Mail: support.morphoindia@morpho.com Tel: 0120-4699900 Europe and rest of the world: Mail: hotline-biometrics@morpho.