Instructions

B-1902-1(0)
INSTRUCTION SHEET - HS5D Series Safety Switch
( 1 / 5 )
2016.08
1
Type
HS5D-11ZRNM
Contact configration
11 : 1NO-1NC
02 : 2NC
12 : 1NO-2NC
03 : 3NC
Gland Port Size
Blank : G1 /2
M : M20
P : PG13.5
Material of Head
Blank : Plastic
Z : Metal
Ratings approved by safety agencies
(1) TÜV rating / CCC rating / KOSHA rating
AC-15 250V, 3A
DC-13 30V, 4A
(2)UL, c-UL rating
A300 3A, 250V ac, Pilot Duty
4A, 30V dc
EN ISO / ISO14119
IEC60947-5-1, EN60947-5-1, GS-ET-15
UL508, CSA C22.2 No.14, GB14048.5
IEC60204-1, EN60204-1
Low Voltage Directive, Machinery Directive
10A
900 operations / hour
0.05 to 1.0 m/s
10 mm minimum (HS9Z-A51)
50 N minimum (HS9Z-A51)
50mΩ maximum (Initial value)
IP67 (IEC60529)
250V AC, 10A fast acting type fuse
30V
10A
10A
8A
4A
125V
10A
5A
2.2A
1.1A
250V
6A
3A
1.1A
0.6A
Resistive load (AC12)
Induc ive load (AC15)
Resistive load (DC12)
Induc ive load (DC13)
Applicable Standards
Standards for Use
Applicable Directives
Thermal Current ‹Ith›
Contact Ra ings
‹Ue, Ie›
Operating Frequency
Operating Speed
Direct Opening Travel
Direct Opening Force
Contact Resistance
Degree of Protection
Short-Circuit Protective Device
AC
DC
Operating Condition
Operating Temperature
Operating Humidity
Pullution Degree
-30 to +70°C (no freezing)
45 to 85%RH (no condensation)
3 (Inside 2)
Al itude
2000m maximum
Impulse with voltage ‹Uimp›
4kV
Rated Insula ion voltage ‹Ui›
300V
Mechanical Durability
1,000,000 operations minimum (GS-ET-15)
B10d
Electrical Durability
Conditional short circuit current
2,000,000 (EN ISO 13849-1 Annex C Table C.1)
100A(250V)
100,000 operations min. (AC-12 250V•6A)
1,000,000 operations min. (AC/DC 24V 100mA)
(900 operations / hour)
HS5D
Safety Switch
HS9Z-SH5
Actuator
Hinged
Door
HS9Z-A52
Actuator
Door Stop
HS5D
Safety Switch
Door
HS9Z-A51
Actuator
(Examples of Mounting on Sliding Doors)
(Examples of Mounting on Hinged Doors)
2
Specifications and Ratings
3
Mounting Examples
Class of Protection
Class II (IEC61140)
Confirm that the delivered product is what you have ordered.
Read his instruction sheet to make sure of correct operation.
In this operation instruction sheet, safety precautions are categorized in order of
importance to Warning and Caution :
Warning notices are used to emphasize that improper operation may cause severe
personal injury or death.
Caution notices are used where inattention might cause personal injury or damage to
equipment.
INSTRUCTION SHEET
Original Instructions
Safety Switch
HS5D Series
SAFETY PRECAUTIONS
CAUTION
WARNING
* In order to verify if the product
you are interested in is certified
with the S mark, please check
the following section on our
website: "List of type numbers
certified with the S mark"
Install the interlock switch on the immovable machine or guard, and install the
actuator on the movable door. Do not install both interlock switch and actuator on
themovable door, otherwise the angle of insertion of the actuator to the safety switch
may become inappropriate, and failure will occur.
Changing the Mounting Directions of
the HS5D Head
The head of HS5D can be mounted in four
directions by removing the four screws on
the corners of the HS5D head.
WARNING
Mounting Directions of the HS5D Head
When replacing the HS5D head, make sure that no foreign object enters into the
safety switch.
Tighten the screws tightly, o herwise he safety switch may malfunction.
Don't remove the screws of head expect when the mouting directions of head is
changed.
• When tightening the screw in the head section with an electric screwdriver or
similar tool, temporarily tighten the first part of the screw by hand first, and then
tighten with the electric screwdriver.
Mounting the HS5D Head
Do not use the metal head for the HS5L with lock type. Be sure to use the plastic
head or metal head for the HS5D. Be sure to use the correct head.
When
Shipped
Alternative Moun ing
Directions
Color:
Red
HS5D
Metal HeadPlastic Head Metal Head
HS5L
Metal,
Color:Silver
Metal,
Color:Silver
Plastic,
Color Red
Color:Black
Shock Resistance
Vibration Resistance
Damage Limits: 1000m/s
2
Operating Extremes:10 to 55 Hz, half amplitude 0.5mm
Damage Limits: 30 Hz, half amplitude 1.5mm
10 operations min.
100MΩ(Initial value)
1,000V 1minute(Initial value)
Mechanical durability
Insulation resistance
Dielectric strength
HS5D Head Removal Detection Function (Screw Terminal No.11-12)
Interlocking device Type
/ the level of coded
Type 2 Interlocking device
/ low level coded actuator (EN ISO / ISO14119)

Summary of content (5 pages)