TM Web Management User Manual Industrial Managed Ethernet Switch Version 1.0 This document applied to models of MSM-508,MSM-508FC/FCS/FT Co p yr i gh t April 29, 2008 © IC P D A S C o. , Lt d. , A l l R i gh ts Re s er ve d .
CONTENTS 1. Web Connection .......................................................................... 2 2. Basic Setting ............................................................................... 4 Information................................................................................ 4 Network .................................................................................... 5 Serial Port..................................................................................
10.Authentication .......................................................................... 22 Account ....................................................................................22 Accessible IP .............................................................................23 Default Setting ..........................................................................24 Reboot Setting ..........................................................................
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Managed Switch Web Management Operation This manual will guide you how to configure Connection Basic Setting Redundant Setting Port configuration Relay Alarm Email Alarm VLAN QoS Diagnosis Authentication ICPDAS Managed Switch through web browser. Web Management support two levels of authentication : administrator level and user level.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 1. Web Connection The default network setting (factory default setting) of Managed Switch is : IP : 192.168.255.1 Mask : 255.255.0.0 Gateway : 192.168.0.1 Before accessing Managed Switch through web browser, please modify above setting to fit your network environment, you can refer「RS-232 Console Operation」manual for more detail. Following, we will show you how to connect to the Web Management step by step.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual For login to Web Management, your browser must support HTTP authentication. It allows a web browser to provide credentials when making a request.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 2. Basic Setting This chapter describes how to setting the commonly information on your Managed Switch. Information Module Name: : Use to specify the Switch Name, and also displayed as the console prompt. Max. 8 characters. Module Information: : Use to memo the extra description of the Switch Module. 16 characters max.. Web Server TCP Port: : Specify the connection port of the Web Server. Default setting is 80.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Only MS Series Switch supports a real time clock. For RS Series Switch, the function is invalid. Network IP Address: : IP address is an identifier for a device on a TCP/IP network. It is a 32-bit numeric address consisted as four numbers separated by three dots. The range of each number is from 0 to 255. Managed Switch doesn’t support dynamic IP assignment, you have to specify the IP address of each Switch manually.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Mask: : The (subnet) MASK is used to determine the subnet of an IP address. Same as the IP address, a MASK contains four bytes (32 bits) and it is often expressed in the dotted-decimal notation. The factory default value is labeled beside the Switch case. MAC Address: : MAC Address is a hardware address. It’s a uniquely identifies the device of MAC layer network.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual COM1 port is the RS232 standard, use for Console Connection. Factory default setting is: Baud Rate : 115200 Data Bit :8 Parity Check : 0 (None) Stop Bit :1 COM2 is the RS485 standard, use for Modbus communication. Factory default setting is: Baud Rate : 115200 Data Bit :8 Parity Check : 0 (None) Stop Bit :1 Digital Input / Output ICPDAS Managed Switch supports 3 points of digital input / output interface.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 3. Redundant Setting Redundant LAN topology is a structure to provide the link failure recovery and escaping network loops. It allows you to setup the redundant loops for supporting backup connections. Managed Switch offers redundancy options for various functions, it is a highly reliability device provides the fast error detection and keeps the non-stop connections 24 hours a day, 365 days a year.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Recovery Time Setting Recovery Time (Cyber-Ring Protocol): : Recovery time is the duration of connections that from failure occurred to return to normal. This function allows you to assign the recovery time in millisecond (ms), the variable is from 100ms to 1500ms (1.5 sec). Factory default is 300ms.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Forward Time (STP Protocol): : Forward delay is the duration time that packages from pre-forwarding state to forward state. Factory default is 10000ms, the variable is from 4000ms to 30000ms (30 sec). Setting is only available on STP Mode. Maxage Time (STP Protocol): : Max age time is the interval that node Switches waiting for hello messages from the Master Switch.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 4. Port configuration Mirror Mirror Port setting is commonly used to monitor the network traffic, it can help you to collect and trace abnormal packets of each port without interrupting data transmission. User can specify a switch port to receive the packet copies which from another port. STEP 1 Specify a “Monitor Port” that you want to get the packet copies. STEP 2 Specify the ports will be monitored.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Trunking This function is used for setting the groups of link aggregation. Port trunking allows user to combine multiple physical ports into a single logical channel. It can increase the link speed and provide the better redundancy availability. Supported groups depend on the total number of switch ports on the equipment. 508 Series Managed Switch supports up to 4 trunking groups.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Port Port Number Speed Port transmission speed.(10 Mbps/100 Mbps) Duplex Flow Control Mode. Both Half-duplex and Full-duplex modes are supported. Link Port Link status. ON : Link is up ; OFF : Link is down. Cable Checking This function provides a useful tool to detect the quality of cables. Tick the checkbox of Ports and click “Start Check” button, after a moment waiting, system will report the RX and TX status.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 5. Relay Alarm Managed Switch offer a relay contact output on Terminal Block of the Switch equipment. It is able to connect to a light, buzzer …etc. warning device and notify system failures immediately. We also offer the web tool to configure the relay manually. It’s convenient for you to enable/disable relay warnings since the Switch equipments are far from you.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 6. Email Alarm ICPDAS Managed Switch can notify you by email when the specified event occurred. This chapter will guide you how to setting the related parameters. Alarm Event setting User can specify system and port events that warning emails will be sent. Power1 ON The status of power1 from OFF turns to ON. Power2 ON The status of power2 from OFF turns to ON. Power1 OFF The status of power1 from ON turns to OFF.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Email Setting User can select “Disable Alarm Mail” to stop the email alarm sending (factory default). If email alarm is enabled, there are two methods of email report for you select. The first one is: warning mail is sent immediately when events occur. The second is: user can specify the interval time between 1 to 99 hour(s), and system will sending the system report by email every the specified hour(s).
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Email Record Switch Management can keep the sending date, time and status of each warning emails. But only the latest 50 sending records will be saved. User can click the “Clean Record Table” button to delete all the email sending history.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 7. VLAN Virtual LANs (VLAN) allows you to setting logical groups of devices, even they are not located on the same physical segment. The logical group called a VLAN, all devices belong to the VLAN has the same network attributes, and it’s isolated from the other network logically. A VLAN provides higher communication security, and makes you to limit traffic flooding easily.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Port based VLANs In this function, user can determine the output ports which this input port can send frames to. For example, in above figure, only the ingress come from Port 4 and Port 8 can be send out from Port 1. 802.1Q VLANs If the 802.1Q VLAN Mode is enabled, you have to specify the VLAN groups to restrict the ingress and egress. Switch Management supports the different VID setting up to 64 in max.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 8. QoS Quality of Service (QoS) provides different priority to different data flow. It can make you to classify and prioritize data frames. ICPDAS Managed Switch support 4 classes of services priority queues. This function allows you to determine the QoS tag priority and specify the priority processing scheme. QoS Mode There are two options supported to classify egress frames.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual IP ToS/DiffServ Enable/Disable specified ports using the TOS (Type of Service) and/or DiffServ (Differentiated Service) field in IPv4 frame. 802.1p Tag over Tos/DiffServ If <802.1p Tag Priority> and are both enabled, you have to decide a priority between those two settings. Enable : Use tag fields for priority mapping when both field types are present.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual 9. Diagnosis Ping In this function, user can input the IP address and click SUMIT button to check if the IP is reachable. 10. Authentication Account There are two levels of authentication are provided in Switch Management: administrator level and user level. Administrator level allows you to monitor and configure all functions of Switch Management, and the user level is for monitor-only.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual At the system initial, the default account and password are: Admin and Admin. Accessible IP You can set the remote IP address here to filter the illegal access. Only the IP address in following table can be allowed to access Managed Switch. Before UPDATE the setting, you have to tick the checkbox, otherwise system will ignore the setting data.
Industrial Ethernet Layer 2 Managed Switch – Web Management Manual Default Setting This function allows you to clean all settings and load the default value to Switch Management. Current factory default values are: Network Setting IP Address : 192.168.255.1 Gateway : 192.168.0.1 Mask : 255.255.0.